细化搜索
结果 1-10 的 17
Endogenous creatinine clearance measurement of glomerular filtration rate in dogs.
1993
Finco D.R. | Tabaru H. | Brown S.A. | Barsanti J.A.
Renal clearance procedures were performed on adult mixed-breed dogs with a wide range of renal function. Endogenous creatinine clearance was computed after analyzing plasma and urine for creatinine by use of 2 methods, PAP and kinetic Jaffe. For 20-minute clearance procedures, [14C]inulin clearance was measured simultaneously with endogenous creatinine clearance. For 111 twenty-minute clearance procedures performed on 24 dogs, [14C]inulin clearance was highly correlated with creatinine clearance for both methods of creatinine analysis (R2 = 0.979 for [14C]inulin-PAP; R2 = 0.943 for [14C]inulin-Jaffe). The absolute values for PAP and [14C]inulin clearance were nearly the same (PAP-to-[14C]inulin clearance ratio = 1.03 +/- 0.08), but those for Jaffe clearance were substantially less than those for [14C] inulin clearance Jaffe-to-[14C]inulin clearance ratio = 0.88 +/- 0.10). The Jaffe-to-[14C] inulin clearance ratio was inversely correlated with degree of renal function (R2 = 0.464), whereas the PAP-to-[14C]inulin clearance ratio was not correlated with degree of renal function (R2 = 0.060). Thus, Jaffe-determined creatinine clearance varied, in relation to [14C] inulin clearance, depending on degree of renal function. In 4 clinically normal dogs, 20-minute and 24-hour sample collections analyzed by use of the PAP method gave clearance values significantly greater, for both periods, than did Jaffe analyses. The PAP-determined creatinine clearance values were less than, but not significantly different from 20-minute exogenous creatinine clearance values determined 10 days after 24-hour collections. For 20-minute and 24-hour collections, the difference in clearance values between the PAP and Jaffe methods was attributable mostly to lower plasma creatinine values for the PAP method (mean +/- SEM, plasma PAP-to-Jaffe ratio = 0.798 +/- 0.053). However, urine creatinine values also were less by use of the PAP method.
显示更多 [+] 显示较少 [-]Preparation and transfusion of canine platelet concentrates.
1993
Abrams Ogg A.C.G. | Kruth S.A. | Carter R.F. | Valli V.E. | Kamel Reid S. | Dube I.D.
A protocol was developed for preparation of platelet concentrates (PC) to support thrombocytopenic dogs. Four clinically normal dogs with platelet counts that ranged from 200 to 330 X 10(9) platelets/L were used as donors. One unit (450 ml) of blood was collected by venipuncture into a double blood bag. Whole blood (WB) was centrifuged for 4 minutes at 1,000 X g (braking time = 2 minutes, 30 seconds) to prepare platelet-rich plasma (PRP). The PRP was expressed into the satellite bag and was centrifuged for 10 minutes at 2,000 X g (braking time = 2 minutes, 36 seconds). The platelet-poor plasma was expressed, leaving 40 to 70 ml of plasma and the pelleted platelets in the satellite bag. The resulting PC was left undisturbed for 60 minutes to promote disaggregation, and the platelets were then resuspended by gentle manual agitation. Forty-eight PC were prepared. Mean (+/- SD) platelet yield from WB to PRP was 78 +/- 13)% (range, 35 to 97%); yield from PRP to PC was 94 (+/- 6) % (range, 75 to 100%); and overall yield (PC from WB) was 74 (+/- 13) % (range, 36 to 91%). Mean PC platelet count was 8.0 (+/- 3.0) X 10(10) platelets/PC (range, 2.3 to 13.4 X 10(10) platelets/PC). The WBC content was 0.1 to 2.3 X 10(9) platelets/PC, representing 3 to 74% of WBC in the WB. Hematocrit was 0.1 to 26.2%. Results of bacterial and fungal culturing were negative.
显示更多 [+] 显示较少 [-]In vitro evaluation of four methods of attaching transfixation pins into a fiberglass cast for use in horses.
1996
McClure S.R. | Watkins J.P. | Hogan H.A.
Estimation of glomerular filtration rate and evaluation of renal function in ferrets (Mustela putorius furo).
1994
Esteves M.I. | Marini R.P. | Ryden E.B. | Murphy J.C. | Fox J.G.
Three methods of determining glomerular filtration rate (GFR) were performed in adult ferrets, 9 months to 7 years old. Endogenous creatinine clearance was determined, using serum and urine creatinine values obtained during 24- and 48-hour collection periods from 27 ferrets housed in metabolic cages. Creatinine and radiolabeled inulin were administered to 12 female ferrets by constant IV infusion during isoflurane-induced anesthesia. Serial 20-minute urine collections, together with serum samples obtained at the midpoint of urine collection, provided measures for clearance calculations of these substances. Mean +/- SD endogenous creatinine clearance in ferrets for metabolic cage collections was 2.50 +/- 0.93 ml/min/ kg of body weight. There were no significant differences between the 24- and 48-hour clearance rates. Mean inulin clearance was 3.02 +/- 1.78, and mean exogenous creatinine clearance was 3.32 +/- 2.16 ml/ min/kg. Analysis of variance, using least-squared means adjustment, did not yield any significant differences between inulin and exogenous creatinine clearance rates. Exogenous creatinine clearance-to-inulin clearance ratio was 0.99 +/- 0.46, and there was significant correlation between the 2 methods (r = 0.82, P = 0.0001). Significant body temperature effects on inulin or exogenous creatinine clearance were not found. Infused inulin clearance, the generally preferred method for GFR calculation in mammalian species, was significantly (P = 0.0069) higher in younger (3.65 ml/min/kg) vs older ferrets (2.29 ml/min/kg). Results of this study indicate that inulin clearance is an adequate measure of GFR in ferrets as it is in other species. Compared with inulin clearance, exogenous creatinine clearance also provides a reliable estimate of GFR in ferrets.
显示更多 [+] 显示较少 [-]Effects of abdominal insufflation with nitrous oxide on cardiorespiratory measurements in spontaneously breathing isoflurane-anesthetized dogs.
1993
Gross M.E. | Jones B.D. | Bergstresser D.R. | Rosenhauer R.R.
Cardiorespiratory effects of abdominal insufflation were evaluated in 8 dogs during isoflurane anesthesia. Each dog was studied 3 times, in 1 of the following orders of insufflation pressures: 10-20-30, 20-30-10, 30-20-10, 10-30-20, 20-10-30, and 30-10-20 mm of Hg. Anesthesia was induced by use of a mask, dogs were intubated, and anesthesia was maintained by isoflurane in 100% oxygen. After instrumentation, baseline values were recorded (time 0), and the abdomen was insufflated with nitrous oxide. Data were recorded at 5, 10, 15, 20, 25, and 30 minutes after insufflation. The abdomen was then desufflated, with recording of data continuing at 35 and 40 minutes. Mean arterial pressure increased at 5 minutes during 20 mm of Hg insufflation pressure, and from 20 to 30 minutes during 30 mm of Hg pressure. Tidal volume decreased from 5 to 30 minutes during 10 and 20 mm of Hg pressures, and from 5 to 40 minutes during 30 mm of Hg pressure. Minute ventilation decreased at 10 and 20 minutes during 20 mm of Hg pressure. End-tidal CO2 concentration increased from 5 to 30 minutes during 20 and 30 mm of Hg pressure. The PaCO2 decreased at 40 minutes during 10 mm of Hg pressure, at 30 minutes during 20 mm of Hg pressure, and from 10 to 40 minutes during 30 mm of Hg pressure. Values for pH decreased from 10 to 30 minutes during 20 and 30 mm of Hg pressures. The PaO2 decreased from 20 to 40 minutes during 10 mm of Hg pressure, at 30 minutes during 20 mm of Hg pressure, and from 10 to 40 minutes during 30 mm of Hg pressure. Percentage decrease in tidal volume was greater at 5 and 15 minutes with 30 mm of Hg pressure. Differences in percentage increase in end tidal CO2 concentration were observed among the 3 pressures from 5 to 30 minutes. Although significant, these changes do not preclude use of laparoscopy if insufflation pressure > 20 mm of Hg is avoided.
显示更多 [+] 显示较少 [-]Non-surgical embryo recovery in the water buffalo.
1988
Ocampo M.B. | Uenishi R.S. | Valdez C.A. | Pastor J. | Cruz L. | Kanagawa H.
Detection of equine immunoglobulin-secreting cells by a plaque assay
1992
Goto, I. (Hokkaido Univ., Sapporo (Japan). Faculty of Veterinary Medicine) | Kamada, M. | Inaba, M. | Maede, Y.
Superovulation response of upgraded indigenous Philippine goat (Capra hircus)
1988
Ocampo, M.B. (Hokkaido Univ., Sapporo (Japan). Faculty of Veterinary Medicine) | Uenishi, R.S. | Valdez, C.A. | Muralla, Z. | Hishinuma, M. | Kanagawa, H.
Availability of oral swab sample for the detection of bovine viral diarrhea virus (BVDV) gene from the cattle persistently infected with BVDV
2008
Tajima, M.(Hokkaido Univ., Sapporo (Japan)) | Ohsaki, T. | Okazawa, M. | Yasutomi, I.
Bovine nasal and oral discharges were used as samples for bovine viral diarrhea virus (BVDV) gene detection. Viral genes in serum (S), nasal discharge (N) and oral discharge (O) were quantified with real-time polymerase chain reaction using SYBR Green by the relative quantification method, and findings were compared among samples. Although the quantity of the BVDV gene in S was greater than those in N and O, all samples were available to identify persistently infected (PI) cattle with BVDV by reverse transcription polymerase chain reaction (RT-PCR). The swab samples were able to be stored for a few days at 4degC with a little decrease of amplification signal in RT-PCR. Oral swab sampling was easier than nasal swab sampling, and was also less uncomfortable for the cattle than other sampling methods without pain or unnecessary retention. This sampling method can be performed without any special technique and equipment. Therefore, the oral swab sampling method is useful for screening to detect BVDV PI cattle by RT-PCR.
显示更多 [+] 显示较少 [-]Preliminary survey for antibodies against five bovine viruses [bovine leukemia virus; infectious bovine rhinotracheitis virus; adeno virus; akabane virus; parainfluenza virus] in cattle in Korea
1982
Choi, W.P. | Izawa, H. | Onuma, M. | Kodama, H. | Mikami, T. (Hokkaido Univ., Sapporo (Japan). Faculty of Veterinary Medicine) | Ohnuma, T. | Hashiguchi, Y.