细化搜索
结果 1-7 的 7
Predictive value of plasma parameters in the risk of postpartum ketosis in dairy cows
2017
Cao, Yu | Zhang, Jiang | Yang, Wei | Xia, Cheng | Zhang, Hong-You | Wang, Yan-Hui | Xu, Chuang
Introduction: The predictive value of selected parameters in the risk of ketosis and fatty liver in dairy cows was determined. Material and Methods: In total, 21 control and 17 ketotic Holstein Friesian cows with a β-hydroxybutyrate (BHBA) concentration of 1.20 mmol/L as a cut-off point were selected. The risk prediction thresholds for ketosis were determined by receiver operating characteristic (ROC) curve analysis. Results: In the ketosis group, paraoxonase-1 (PON-1) activity and concentration of PON-1 and glucose (GLU) were decreased, and aminotransferase (AST) activity as well as BHBA and non-esterified fatty acid (NEFA) contents were increased. The plasma activity and concentration of PON-1 were significantly positively correlated with the level of plasma GLU. The plasma activity and concentration of PON-1 were significantly negatively correlated with the levels of AST and BHBA. According to ROC curve analysis, warning indexes of ketosis were: plasma PON-1 concentration of 46.79 nmol/L, GLU concentration of 3.04 mmol/L, AST concentration of 100 U/L, and NEFA concentration of 0.82 mmol/L. Conclusion: This study showed that the levels of PON-1, GLU, AST, and NEFA could be used as indicators to predict the risk of ketosis in dairy cows.
显示更多 [+] 显示较少 [-]Correlation between serum homocysteine concentration and severity of mitral valve disease in dogs
2017
Lee, Change-Min | Jeong, Da-Min | Kang, Min-Hee | Kim, Seung-Gon | Han, Jae-Ik | Park, Hee-Myung
OBJECTIVE To measure serum homocysteine concentrations in dogs with myxomatous mitral valve disease (MMVD) and identify any association between this variable and stage of MMVD. ANIMALS 53 client-owned dogs with MMVD and 10 healthy control Beagles. PROCEDURES Dogs with MMVD were allocated to 3 groups in accordance with the staging system for chronic valvular heart disease in dogs and cats of the American College of Veterinary Internal Medicine. Blood samples were collected from all dogs, and serum homocysteine and cardiac troponin 1 concentrations were measured by enzyme immunoassay and chemiluminescence immunoassay, respectively. Analyte values were tested for associations with each other and with stage of MMVD. RESULTS A significant correlation was identified between serum homocysteine concentration and stage of MMVD. Mean ± SD concentrations were 6.72 ± 1.65 μmol/L for control dogs, 13.37 ± 4.16 μmol/L for dogs with stage B MMVD, 18.86 ± 6.73 μmol/L for dogs with stage C disease, and 28.26 ± 4.48 μmol/L for dogs with stage D disease. In addition, serum homocysteine concentration was correlated with serum cardiac troponin 1 (r = 0.34) and creatinine (r = 0.46) concentrations, systolic blood pressure (r = 0.57), and left atrium-to-aortic root ratio (r = 0.28), all of which were positively correlated with stage of MMVD. CONCLUSIONS AND CLINICAL RELEVANCE Serum homocysteine concentrations of dogs with MMVD were significantly higher than those of control dogs, and significant correlations were identified between these values and several risk factors for heart failure. Measurement of serum homocysteine concentration may be useful in the prediction of severity of disease in dogs with MMVD.
显示更多 [+] 显示较少 [-]Ability of clinicopathologic variables and clinical examination findings to predict race elimination in endurance horses
2017
Fielding, C Langdon | Meier, Chloe A. | Fellers, Greg K. | Magdesian, K Gary
OBJECTIVE To compare results of point-of-care laboratory testing with standard veterinary clinical examination findings at a single time point during endurance competition to identify horses at risk for elimination. ANIMALS 101 endurance horses participating in the 2013 Western States 160-km (100-mile) endurance ride. PROCEDURES At the 58-km checkpoint, blood samples were collected from all horses. Samples were analyzed for pH, Pco2, base excess, anion gap, PCV, and whole blood concentrations of sodium, potassium, chloride, total carbon dioxide, BUN, glucose, and bicarbonate. Corrected electrolyte and PCV values were calculated on the basis of plasma total protein concentration. Immediately following the blood sample collection, each horse underwent a clinical examination. In addition to standard examination variables, an adjusted heart rate was calculated on the basis of the variable interval between entry into the checkpoint and heart rate recording. A combination of stepwise logistic regression, classification and regression tree analysis, and generalized additive models was used to identify variables that were associated with overall elimination or each of 3 other elimination categories (metabolic elimination, lameness elimination, and elimination for other reasons). RESULTS Corrected whole blood potassium concentration and adjusted heart rate were predictive for overall elimination. Breed, plasma total protein concentration, and attitude were predictive for elimination due to metabolic causes. Whole blood chloride concentration and corrected PCV were predictive for elimination due to lameness. Corrected PCV was predictive for elimination due to other causes. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that for horses in endurance competition, a combination of breed and clinical examination and laboratory variables provided the best prediction of overall elimination.
显示更多 [+] 显示较少 [-]Preliminary study on classification of raw bovine’s milk using ATR-FTIR coupled with PCA from Peninsular Malaysia
2017
Ketty G. S. L. | Norakmar I. | Falizah I. | Kamaliah G. | Izwan I. | Faridah I. | Khairunnisak M. | Saipul B. A. R. | Marni S. | Roosnoor F. H.
A classification of raw bovine’s milk samples according to theirgeographical origin in Peninsular Malaysia by Makmal Kesihatan Awam Veterinar, Department of Veterinary Services Malaysia (DVS). Six hundred bovine milk samples were collected from Perlis, Kedah, Perak, Selangor, Pahang, Negeri Sembilan, Melaka and Johor states by 26 milkcollecting centres under DVS. This study was carried out directly using attenuated total reflectance Fourier transform infrared(ATR-FTIR) spectroscopy method coupled with a multivariate principal component analysis (PCA). The spectra generated by ATR-FTIR were analysed and regions of interest were found in between 3851.651cm-1 until 2700.819 cm-1 and 2419.173 cm-1 until 977.368 cm-1. The absorbance and wavenumber data of the regions were then analysed using PCA and the results show presence of clustering towards theirgeographical origin. ATR-FTIR coupled with multivariate PCA has potential for classifying the geographical origin of raw milk produced within Peninsular Malaysia. This method provides a rapid and nondestructive secondary methodology in milk classification without further sample preparation.
显示更多 [+] 显示较少 [-]Evaluation of canine hepatic masses by use of triphasic computed tomography and B-mode, color flow, power, and pulsed-wave Doppler ultrasonography and correlation with histopathologic classification
2017
Griebie, Erin R. | David, Frederic H. | Ober, Christopher P. | Feeney, Daniel A. | Anderson, Kari L. | Wuenschumann, Arno | Jessen, Carl R.
OBJECTIVE To determine clinical relevance for quantitative and qualitative features of canine hepatic masses evaluated by use of triphasic CT and B-mode, color flow, power, and pulsed-wave Doppler ultrasonography and to compare diagnostic accuracy of these modalities for predicting mass type on the basis of histopathologic classification. ANIMALS 44 client-owned dogs. PROCEDURES Dogs with histopathologic confirmation (needle core, punch, or excisional biopsy) of a hepatic mass were enrolled. Triphasic CT and B-mode, color flow, power, and pulsed-wave Doppler ultrasonography of each hepatic mass were performed. Seventy quantitative and qualitative variables of each hepatic mass were recorded by 5 separate observers and statistically evaluated with discriminant and stepwise analyses. Significant variables were entered in equation-based predictions for the histopathologic diagnosis. RESULTS An equation that included the lowest delayed-phase absolute enhancement of the mass and the highest venous-phase mass conspicuity was used to correctly classify 43 of 46 (93.5%) hepatic masses as benign or malignant. An equation that included only the lowest delayed-phase absolute enhancement of the mass could be used to correctly classify 42 of 46 (91.3%) masses (with expectation of malignancy if this value was < 37 Hounsfield units). For ultrasonography, categorization of the masses with cavitations as malignant achieved a diagnostic accuracy of 80.4%. CONCLUSIONS AND CLINICAL RELEVANCE Triphasic CT had a higher accuracy than ultrasonography for use in predicting hepatic lesion classification. The lowest delayed-phase absolute enhancement of the mass was a simple calculation that required 2 measurements and aided in the differentiation of benign versus malignant hepatic masses.
显示更多 [+] 显示较少 [-]Effectiveness of manual bladder expression in paraplegic dogs
2017
Carwardine, Darren R. | Rose, Jeremy H. | Harcourt-Brown, Thomas R. | Granger, Nicolas
OBJECTIVE To determine the effectiveness of manual bladder expression in paraplegic dogs by comparing urine volumes measured by use of intermittent catheterization and ultrasonography. ANIMALS 36 paraplegic dogs. PROCEDURES 93 measurements of bladder volume were collected for the 36 dogs. Residual urine volume was determined by use of intermittent urethral catheterization and estimated by use of ultrasonography. RESULTS Manual bladder expression voided a mean of 49% of urine from the bladder in this population of dogs. There was no correlation (R2, 0.06) between the effectiveness of manual bladder expression and body weight. Ultrasonographic estimation of bladder volume had good correlation (R2, 0.62) with bladder volume determined by use of intermittent bladder catheterization, but clinically unacceptable variation for predicting actual bladder volume (mean difference, 22 mL; 95% confidence interval, −96 to 139 mL). CONCLUSIONS AND CLINICAL RELEVANCE Manual bladder expression was ineffective at completely emptying urine from the bladder of paraplegic dogs, but the effectiveness of the procedure was not affected by body weight. Manual bladder expression would likely be a useful procedure to prevent increases in pressure within the bladder. Ultrasonographic estimation of bladder volume could be a useful predictor of actual bladder volume, but it was susceptible to wide variations among dogs, and results should therefore be interpreted with caution.
显示更多 [+] 显示较少 [-]Assessment of contrast-enhanced ultrasonography of the hepatic vein for detection of hemodynamic changes associated with experimentally induced portal hypertension in dogs
2017
Morishita, Keitaro | Hiramoto, Akira | Michishita, Asuka | Takagi, Satoshi | Hoshino, Yuki | Itami, Takaharu | Lim, Sue Yee | Osuga, Tatsuyuki | Nakamura, Sayrui | Ochiai, Kenji | Nakamura, Kensuke | Ohta, Hiroshi | Yamasaki, Masahiro | Takiguchi, Mitsuyoshi
OBJECTIVE To assess the use of contrast-enhanced ultrasonography (CEUS) of the hepatic vein for the detection of hemodynamic changes associated with experimentally induced portal hypertension in dogs. ANIMALS 6 healthy Beagles. PROCEDURES A prospective study was conducted. A catheter was surgically placed in the portal vein of each dog. Hypertension was induced by intraportal injection of microspheres (10 to 15 mg/kg) at 5-day intervals via the catheter. Microsphere injections were continued until multiple acquired portosystemic shunts were created. Portal vein pressure (PVP) was measured through the catheter. Contrast-enhanced ultrasonography was performed before and after establishment of hypertension. Time-intensity curves were generated from the region of interest in the hepatic vein. Perfusion variables measured for statistical analysis were hepatic vein arrival time, time to peak, time to peak phase (TTPP), and washout ratio. The correlation between CEUS variables and PVP was assessed by use of simple regression analysis. RESULTS Time to peak and TTPP were significantly less after induction of portal hypertension. Simple regression analysis revealed a significant negative correlation between TTPP and PVP. CONCLUSIONS AND CLINICAL RELEVANCE CEUS was useful for detecting hemodynamic changes associated with experimentally induced portal hypertension in dogs, which was characterized by a rapid increase in the intensity of the hepatic vein. Furthermore, TTPP, a time-dependent variable, provided useful complementary information for predicting portal hypertension. IMPACT FOR HUMAN MEDICINE Because the method described here induced presinusoidal portal hypertension, these results can be applied to idiopathic portal hypertension in humans.
显示更多 [+] 显示较少 [-]