细化搜索
结果 1-10 的 16
Efficacy of prosthetic laryngoplasty with and without bilateral ventriculocordectomy as treatments for laryngeal hemiplegia in horses.
1996
Tetens J. | Derksen F.J. | Stick J.A. | Lloyd J.W. | Robinson N.E.
Therapeutic effects of revascularisation on the healing of free bone grafts in dogs
2020
Zheng, Jia-San | Ruan, Hong-Ri | Shuang-Qiu, | Jing-Nie, | Hou, Kai-Wen | Rui-Wu,
The therapeutic effect of subcutaneous embedding and revascularisation on the repair of canine bone defects caused by open fracture was examined. A total of 12 adult beagle dogs were randomly split into a control group (group C) and a test group (group T). A section of the radius was removed from each dog under general anaesthesia and the deficit supported by an orthopaedic implant. Group T had the section surgically implanted next to the blood vessel–rich saphenous vein and Group C had it cryopreserved at −80°C. After eight weeks, the bone was surgically implanted back into the matching radial deficit. Bone healing was evaluated by gross morphological and X-ray examinations, post-mortem histology, and successive blood measurements of key bone biochemical markers. At 12 weeks, the bone healing boundary was disappearing more quickly in group T dogs than in their group C counterparts. X-ray and histological examinations showed that the cortical repair of group T subjects was complete and the bony plate arrangement was more regular than that in group C. The levels of bone biochemical markers also proved that the healing state of group T was better. The results showed that the degree of healing, osteoclast activity, and bone formation status of group T were better than those of group C, proving that the vascularised bone graft had a significantly shorter healing time than the cryopreserved bone graft.
显示更多 [+] 显示较少 [-]Ex vivo computed tomography evaluation of loading position on morphometry of the caudal cervical intervertebral disk spaces of dogs
2019
Knell, Sebastian C. | Smolders, Lucas A. | Steffen, Thomas | Pozzi, Antonio
OBJECTIVE To provide an objective, quantitative morphometric description of the caudal cervical intervertebral disk (IVD) spaces of dogs. SAMPLE Vertebral specimens consisting of C4 through C7 from 5 medium-sized dogs. PROCEDURES CT images were obtained with the specimens positioned in neutral, flexion, extension, and lateral bending positions. Size and shape of the cranial and caudal end plates, angle between the end plates (IVD wedge angle), and craniocaudal distance (IVD width) between end plates for the 4 loading positions were measured and compared for the 3 segments (C4-5, C5-6, and C6-7). RESULTS End plate size and shape, IVD wedge angle, and IVD width were not significantly different among the 3 segments. Caudal cervical end plates were consistently larger than cranial cervical end plates. The IVD wedge angle ranged from −4.8° to 15.2°. Flexion induced a reduction in IVD width in the ventral portion of the IVD, whereas extension induced a decrease in width in the dorsal portion of the IVD. Central IVD width remained unchanged among the loading positions. CONCLUSIONS AND CLINICAL RELEVANCE Unique morphometric and dynamic characteristics of the caudal cervical IVD space of dogs were detected. These findings may help investigators when designing IVD prostheses for dogs with cervical spondylomyelopathy.
显示更多 [+] 显示较少 [-]Passive ureteral dilation and ureteroscopy after ureteral stent placement in five healthy Beagles
2017
Vachon, Catherine | Defarges, Alice | Brisson, Brigitte | Nykamp, Stephanie | Weese, J Scott | Denstedt, John | Berent, Allyson C.
OBJECTIVE To determine whether passive ureteral dilation (PUD) would occur after an indwelling ureteral stent was left in place in healthy dogs for 2 or 6 weeks, ureteroscopy would be possible at the time of stent removal, and PUD would be reversible after stent removal. ANIMALS 5 healthy adult female Beagles. PROCEDURES A ureteral stent was cystoscopically placed in each ureter of each dog with fluoroscopic guidance (week 0). One stent was removed from 1 ureter in each dog after 2 weeks (ureter group 1), and the other was removed after 6 weeks (ureter group 2); removal timing was randomized. Computed tomographic excretory urography was performed every 2 weeks from weeks 0 through 10 to measure ureteral diameters. Ureteroscopy was attempted at the time of ureteral stent removal in each group. Ureteral diameters were compared among measurement points. RESULTS The degree of PUD was significant after 2 and 6 weeks of stent placement in both ureter groups. Mean diameter of the midportion of the ureter in both groups prior to stent placement was 1.70 mm (range, 1.3 to 2.7 mm). At stent removal, mean diameter of the midportion of the ureter was 2.86 mm (range, 2.4 to 3.1 mm) in group 1 and 2.80 mm (range, 2.1 to 3.4 mm) in group 2. Ureteroscopy was successfully performed in all dogs up to the renal pelvis. Compared with week 0 values for diameter of the midportion of the ureter, the degree of PUD induced by stent placement had reversed by week 8 in group 1 (mean diameter, 2.00 mm [range, 1.5 to 2.3 mm]). CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that ureteral stent placement for 2 weeks would result in sufficient PUD in healthy dogs to allow ureteroscopy at the time of stent removal and that the original ureteral diameter would eventually be restored. Additional research is needed to determine whether findings would be similar for dogs with urinary tract disease.
显示更多 [+] 显示较少 [-]In vitro effects of meloxicam on metabolism in articular chondrocytes from dogs with naturally occurring osteoarthritis
2013
Budsberg, Steven C. | Stoker, Aaron M. | Johnston, Spencer A. | Liska, William | Reno, Lisa R. | Coock, James L.
Objective-To assess effects of in vitro meloxicam exposure on metabolism in articular chondrocytes from dogs with naturally occurring osteoarthritis Sample-Femoral head cartilage from 16 dogs undergoing total hip replacement Procedures-Articular cartilage samples were obtained. Tissue sulfated glycosaminoglycan (SGAG), collagen, and DNA concentrations were measured. Collagen, SGAG, chondroitin sulfate 846, NO, prostaglandin E2 (PGE2), and matrix metalloproteinase (MMP)-2, MMP-3, MMP-9, and MMP-13 concentrations in culture medium were analyzed. Aggrecan, collagen II, MMP-2, MMP-3, MMP-9, MMP-13, ADAM metallopeptidase with thrombospondin type 1 motif (ADAMTS)-4, ADAMTS-5, tissue inhibitor of metalloproteinase (TIMP)-1, TIMP-2, TIMP-3, interleukin-1β, tumor necrosis factor-α, cyclooxygenase-1, cyclooxygenase-2, and nducible nitric oxide synthase gene expression were evaluated. Comparisons between tissues cultured without (control) and with meloxicam at concentrations of 0.3, 3.0, and 30.0 μg/mL for up to 30 days were performed by means of repeated-measures analysis. Results-Meloxicam had no effect on chondrocyte SGAG, collagen, or DNA concentrations. Expression of ADAMTS-5 was significantly decreased in all groups on all days, compared with the day 0 value. On day 3, culture medium PGE2 concentrations were significantly lower in all meloxicam-treated groups, compared with values for controls, and values remained low. Culture medium MMP-3 concentrations were significantly lower on day 30 than on day 3 in all meloxicam-treated groups. Conclusions and Clinical Relevance-Results suggested that in vitro meloxicam treatment of osteoarthritic canine cartilage for up to 30 days did not induce matrix degradation or stimulate MMP production. Meloxicam lowered PGE2 release from this tissue, and effects on tissue chondrocyte content and matrix composition were neutral.
显示更多 [+] 显示较少 [-]Development and validation of a canine radius replica for mechanical testing of orthopedic implants
2012
Little, Jeffrey P. | Horn, Timothy J. | Marcellin-Little, Denis J. | Harrysson, Ola L.A. | West, Harvey A II
Objective-To design and fabricate fiberglass-reinforced composite (FRC) replicas of a canine radius and compare their mechanical properties with those of radii from dog cadavers. Sample-Replicas based on 3 FRC formulations with 33%, 50%, or 60% short-length discontinuous fiberglass by weight (7 replicas/group) and 5 radii from large (> 30-kg) dog cadavers. Procedures-Bones and FRC replicas underwent nondestructive mechanical testing including 4-point bending, axial loading, and torsion and destructive testing to failure during 4-point bending. Axial, internal and external torsional, and bending stiffnesses were calculated. Axial pullout loads for bone screws placed in the replicas and cadaveric radii were also assessed. Results-Axial, internal and external torsional, and 4-point bending stiffnesses of FRC replicas increased significantly with increasing fiberglass content. The 4-point bending stiffness of 33% and 50% FRC replicas and axial and internal torsional stiffnesses of 33% FRC replicas were equivalent to the cadaveric bone stiffnesses. Ultimate 4-point bending loads did not differ significantly between FRC replicas and bones. Ultimate screw pullout loads did not differ significantly between 33% or 50% FRC replicas and bones. Mechanical property variability (coefficient of variation) of cadaveric radii was approximately 2 to 19 times that of FRC replicas, depending on loading protocols. Conclusions and Clinical Relevance-Within the range of properties tested, FRC replicas had mechanical properties equivalent to and mechanical property variability less than those of radii from dog cadavers. Results indicated that FRC replicas may be a useful alternative to cadaveric bones for biomechanical testing of canine bone constructs.
显示更多 [+] 显示较少 [-]Use of biometry and keratometry for determining optimal power of intraocular lens implants in dogs
1991
Gaiddon, J. | Rosolen, S.G. | Steru, L. | Cook, C.S. | Peiffer, R. Jr
Axial length and corneal curvature were determined by use of A-scan ultrasonography and keratometry on both eyes of dogs of various breeds, sizes, and ages. Mean axial length was 20.43 +/- 1.48 mm; axial length was not related to age or sex, but was significantly greater (P = 0.047) in dogs of larger breeds. Mean corneal curvature was 39.94 +/- 2.61 diopters. Dogs of large breeds had significantly (P < 0.001) flatter corneas. Mild, roughly symmetric astigmatism was detected in a majority of dogs. Use of mean values in a theoretic artificial intraocular lens power equation suggests that aphakic dogs require an implant of approximately 40 diopters to achieve emmetropia.
显示更多 [+] 显示较少 [-]Effects of tibial plateau angle and spacer thickness applied during in vitro canine total knee replacement on three-dimensional kinematics and collateral ligament strain
2014
Baker, Katherine M. | Foutz, Timothy L. | Johnsen, Kyle J. | Budsberg, Steven C.
Objective—To quantify the 3-D kinematics and collateral ligament strain of stifle joints in cadaveric canine limbs before and after cranial cruciate ligament transection followed by total knee replacement (TKR) involving various tibial plateau angles and spacer thicknesses. Sample—6 hemi-pelvises collected from clinically normal nonchondrodystrophic dogs (weight range, 25 to 35 kg). Procedures—Hemi-pelvises were mounted on a modified Oxford knee rig that allowed 6 degrees of freedom of the stifle joint but prevented mechanical movement of the hip and tarsal joints. Kinematics and collateral ligament strain were measured continuously while stifle joints were flexed. Data were again collected after cranial cruciate ligament transection and TKR with combinations of 3 plateau angles (0°, 4°, and 8°) and spacer thicknesses (5, 7, and 9 mm). Results—Presurgical (ie, normal) stifle joint rotations were comparable to those previously documented for live dogs. After TKR, kinematics recorded for the 8°, 5-mm implant most closely resembled those of unaltered stifle joints. Decreasing the plateau angle and increasing spacer thickness altered stifle joint adduction, internal rotation, and medial translation. Medial collateral ligament strain was minimal in unaltered stifle joints and was unaffected by TKR. Lateral collateral ligament strain decreased with steeper plateau angles but returned to a presurgical level at the flattest plateau angle. Conclusions and Clinical Relevance—Among the constructs tested, greatest normalization of canine stifle joint kinematics in vitro was achieved with the steepest plateau angle paired with the thinnest spacer. Furthermore, results indicated that strain to the collateral ligaments was not negatively affected by .
显示更多 [+] 显示较少 [-]Effects of sterilization with hydrogen peroxide gas plasma, ethylene oxide, and steam on bioadhesive properties of nylon and polyethylene lines used for stabilization of canine stifle joints
2012
Gatineau, Matthieu | El-Warrak, Alexander O. | Bolliger, Christian | Mourez, Michael | Berthiaume, Frederic
Objective: To compare effects of sterilization with hydrogen peroxide gas plasma (HPGP), ethylene oxide, and steam on bioadhesive properties of nylon and polyethylene lines used for stabilization of canine stifle joints. Sample: Samples of a 36.3-kg test nylon leader line, 57.8-kg test nylon fishing line, and 2-mm ultrahigh–molecular weight polyethylene (UHMWPE) were used. Procedures: In this in vitro study, samples of nylon leader line, fishing line, and UHMWPE sterilized by use of HPGP, ethylene oxide, and steam or unsterilized samples were used. Bacterial adherence on unsterilized and sterilized samples was tested with Staphylococcus epidermidis and Escherichia coli. Five samples were examined for each line type and sterilization condition, and final colony counts were obtained. Results: Bacterial adherence was significantly affected by method of sterilization for all 3 line types. For most of the samples, bacterial adherence was similar or lower when HPGP sterilization was used, compared with results for sterilization via ethylene oxide and steam, respectively. Bacterial adherence was significantly higher for UHMWPE, compared with adherence for the nylon line, regardless of the sterilization method used. Bacterial adherence was higher for nylon fishing line than for nylon leader line for S epidermidis after ethylene oxide sterilization and for E coli after HPGP and ethylene oxide sterilization. Conclusions and Clinical Relevance: Effects of HPGP sterilization on bioadhesive properties of nylon and polyethylene lines compared favorably with those for ethylene oxide and steam sterilization. Also, nylon line may be a more suitable material than UHMWPE for suture prostheses on the basis of bacterial adherence properties.
显示更多 [+] 显示较少 [-]Absence of bactericidal effect of focused shock waves on an in-vitro biofilm model of an implant
2012
Madron, Matthew S. | McClure, Scott R. | Griffith, Ronald W. | Wang, Chong
The objective of this study was to evaluate the bactericidal effect of shock waves (SWs) on gram-negative or gram-positive monocultured biofilms grown on an orthopedic implant in vitro. Cortical bone screws were individually cultured with Escherichia coli or Staphylococcus epidermidis to produce a biofilm. In each run of 8 screws, 6 screws were treated with shock waves and then sonicated to disrupt the biofilm. One screw was sonicated only and one was not shock waved or sonicated before sampling for plate count dilutions. Post-treatment serial dilutions and plate counts were done on an aliquot from the vial containing each screw to obtain the number of colony-forming units (CFUs). Shock waves were at a constant energy of 0.15 mJ/mm2. Pulse number and screw orientation were varied. A linear mixed-effects model was used with “treatment” as a fixed effect and “run” as a random effect. Pairwise comparisons of treatments were performed with Tukey-Cramer’s adjustment for P-values. Sonicated plate counts were greater than nonsonicated counts for each run. When all sonicated screws were compared to all nonsonicated screws, the counts were significantly increased (P = 0.0091). For each paired comparison between sonicated and shock wave treatment, the only significant difference was in the S. epidermidis biofilm treated at 2000 pulses in a horizontal position, which increased the post-treatment count (P = 0.0445). No bactericidal effects were seen on monocultured biofilms on cortical bone screws treated with shock waves.
显示更多 [+] 显示较少 [-]