细化搜索
结果 1-10 的 16
Efficacy of prosthetic laryngoplasty with and without bilateral ventriculocordectomy as treatments for laryngeal hemiplegia in horses.
1996
Tetens J. | Derksen F.J. | Stick J.A. | Lloyd J.W. | Robinson N.E.
Therapeutic effects of revascularisation on the healing of free bone grafts in dogs 全文
2020
Zheng, Jia-San | Ruan, Hong-Ri | Shuang-Qiu, | Jing-Nie, | Hou, Kai-Wen | Rui-Wu,
Therapeutic effects of revascularisation on the healing of free bone grafts in dogs 全文
2020
Zheng, Jia-San | Ruan, Hong-Ri | Shuang-Qiu, | Jing-Nie, | Hou, Kai-Wen | Rui-Wu,
The therapeutic effect of subcutaneous embedding and revascularisation on the repair of canine bone defects caused by open fracture was examined. A total of 12 adult beagle dogs were randomly split into a control group (group C) and a test group (group T). A section of the radius was removed from each dog under general anaesthesia and the deficit supported by an orthopaedic implant. Group T had the section surgically implanted next to the blood vessel–rich saphenous vein and Group C had it cryopreserved at −80°C. After eight weeks, the bone was surgically implanted back into the matching radial deficit. Bone healing was evaluated by gross morphological and X-ray examinations, post-mortem histology, and successive blood measurements of key bone biochemical markers. At 12 weeks, the bone healing boundary was disappearing more quickly in group T dogs than in their group C counterparts. X-ray and histological examinations showed that the cortical repair of group T subjects was complete and the bony plate arrangement was more regular than that in group C. The levels of bone biochemical markers also proved that the healing state of group T was better. The results showed that the degree of healing, osteoclast activity, and bone formation status of group T were better than those of group C, proving that the vascularised bone graft had a significantly shorter healing time than the cryopreserved bone graft.
显示更多 [+] 显示较少 [-]Therapeutic effects of revascularisation on the healing of free bone grafts in dogs 全文
2020
Zheng Jia-San | Ruan Hong-Ri | Shuang-Qiu | Jing-Nie | Hou Kai-Wen | Rui-Wu
The therapeutic effect of subcutaneous embedding and revascularisation on the repair of canine bone defects caused by open fracture was examined.
显示更多 [+] 显示较少 [-]Ex vivo computed tomography evaluation of loading position on morphometry of the caudal cervical intervertebral disk spaces of dogs 全文
2019
Knell, Sebastian C. | Smolders, Lucas A. | Steffen, Thomas | Pozzi, Antonio
OBJECTIVE To provide an objective, quantitative morphometric description of the caudal cervical intervertebral disk (IVD) spaces of dogs. SAMPLE Vertebral specimens consisting of C4 through C7 from 5 medium-sized dogs. PROCEDURES CT images were obtained with the specimens positioned in neutral, flexion, extension, and lateral bending positions. Size and shape of the cranial and caudal end plates, angle between the end plates (IVD wedge angle), and craniocaudal distance (IVD width) between end plates for the 4 loading positions were measured and compared for the 3 segments (C4-5, C5-6, and C6-7). RESULTS End plate size and shape, IVD wedge angle, and IVD width were not significantly different among the 3 segments. Caudal cervical end plates were consistently larger than cranial cervical end plates. The IVD wedge angle ranged from −4.8° to 15.2°. Flexion induced a reduction in IVD width in the ventral portion of the IVD, whereas extension induced a decrease in width in the dorsal portion of the IVD. Central IVD width remained unchanged among the loading positions. CONCLUSIONS AND CLINICAL RELEVANCE Unique morphometric and dynamic characteristics of the caudal cervical IVD space of dogs were detected. These findings may help investigators when designing IVD prostheses for dogs with cervical spondylomyelopathy.
显示更多 [+] 显示较少 [-]Passive ureteral dilation and ureteroscopy after ureteral stent placement in five healthy Beagles 全文
2017
Vachon, Catherine | Defarges, Alice | Brisson, Brigitte | Nykamp, Stephanie | Weese, J Scott | Denstedt, John | Berent, Allyson C.
OBJECTIVE To determine whether passive ureteral dilation (PUD) would occur after an indwelling ureteral stent was left in place in healthy dogs for 2 or 6 weeks, ureteroscopy would be possible at the time of stent removal, and PUD would be reversible after stent removal. ANIMALS 5 healthy adult female Beagles. PROCEDURES A ureteral stent was cystoscopically placed in each ureter of each dog with fluoroscopic guidance (week 0). One stent was removed from 1 ureter in each dog after 2 weeks (ureter group 1), and the other was removed after 6 weeks (ureter group 2); removal timing was randomized. Computed tomographic excretory urography was performed every 2 weeks from weeks 0 through 10 to measure ureteral diameters. Ureteroscopy was attempted at the time of ureteral stent removal in each group. Ureteral diameters were compared among measurement points. RESULTS The degree of PUD was significant after 2 and 6 weeks of stent placement in both ureter groups. Mean diameter of the midportion of the ureter in both groups prior to stent placement was 1.70 mm (range, 1.3 to 2.7 mm). At stent removal, mean diameter of the midportion of the ureter was 2.86 mm (range, 2.4 to 3.1 mm) in group 1 and 2.80 mm (range, 2.1 to 3.4 mm) in group 2. Ureteroscopy was successfully performed in all dogs up to the renal pelvis. Compared with week 0 values for diameter of the midportion of the ureter, the degree of PUD induced by stent placement had reversed by week 8 in group 1 (mean diameter, 2.00 mm [range, 1.5 to 2.3 mm]). CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that ureteral stent placement for 2 weeks would result in sufficient PUD in healthy dogs to allow ureteroscopy at the time of stent removal and that the original ureteral diameter would eventually be restored. Additional research is needed to determine whether findings would be similar for dogs with urinary tract disease.
显示更多 [+] 显示较少 [-]Effect of homologous fibrin adhesive on callus formation and extracortical bone bridging around a porous-coated segmental endoprosthesis in dogs
1993
Roy, R.G. | Markel, M.D. | Lipowitz, A.J. | Gottsauner-Wolf, F. | Taswell, H.F. | Chao, E.Y.S.
Modular, porous-coated, titanium segmental endoprostheses were implanted bilaterally in the femoral diaphysis of 7 adult mixed-breed dogs. Autogenous bone graft in particle form was placed around the implant and bone. In 1 limb, homologous fibrin adhesive was mixed with the graft in situ before soft tissue closure. The contralateral limb was grafted in identical manner, but without fibrin adhesive, and served as a control. Radiography was performed immediately after surgery and 1, 2, 3, 4, 6, 8, 10, and 12 weeks later to assess callus area and bone remodeling. At 12 weeks, dogs were euthanatized and bone/ implant fixation strength was tested under torsion and compared with values for 6 in vitro controls. Histomorphometric and microradiographic analyses of transverse sections of the distal portion of the implanted femurs were performed. Radiographic callus area was significantly (P < 0.05) smaller in the femurs grafted with fibrin adhesive, compared with the contralateral control. New bone formation (21.4 +/- 1.8% vs 19.2 +/- 2.4%), unlabeled bone (64.8 +/- 3.0% vs 67.9 +/- 4.2%), porosity (13.9 +/- 0.7% vs 12.9 +/- .8%), and bone ingrowth into the porous coating (10.3 +/- 0.9% vs 10.0 +/- 1.2%) were not significantly different between fibrin- and nonfibrin-grafted implants, respectively. There were no significant differences in torsional strength of implant fixation between the fibrin- and nonfibrin-grafted femurs or between the in vivo implanted femurs and the in vitro controls. These data indicate that fibrin adhesive may have been advantageous in maintaining apposition of bone graft adjacent to the endoprosthesis, but it probably did not have an enhancing effect on extracortical bone bridging or ingrowth over a porous-coated segmental bone replacement endoprosthesis.
显示更多 [+] 显示较少 [-]Refractive state of aphakic and pseudophakic eyes of dogs
1993
Davidson, M.G. | Murphy, C.J. | Nasisse, M.P. | Hellkamp, A.S. | Olivero, D.K. | Brinkmann, M.C. | Campbell, L.H.
Streak retinoscopy was performed by 5 ophthalmologists on 256 eyes (191 dogs) to determine their postoperative refractive state after cataract extraction. Aphakic and pseudophakic eyes that had been implanted with 1 of 5 intraocular lenses (IOL) with dioptric powers ranging from +14.5 to +38 diopters (D) were studied. By use of ANOVA, breed and body type of dog and individual performing refraction were found to have no detectable effect on final refractive state. Mean refractive state of aphakic eyes was +14.4 +/- 2.10 D. Mean refractive state for different IOL powers was as follows: +14.5 D IOL = +11.54 +/- 1.18 D (n = 13); +30 D IOL = + 5.15 +/- 1.18 D (n = 105); +34.0 D IOL = +3.5 D (n = 1); +36 D IOL +2.34 +/- 0.73 D 9 (n = 61); and +38 D IOL = +1.41 +/- 0.56 D (n = 28). Residual hyperopia ranged from +0.5 D to +2.5 D with +38 D IOL, and no eyes were myopic (overcorrected) by use of any of the IOL studied. linear regression analysis of refractive state on IOL power for aU dogs predicted that dioptric strength of +41.53 D was necessary to best approximate emmetropia for the population as a whole. Body type of the dog had only slight effect (< 1.0 D) on predicted optimal IOL power. Further linear regression analysis of the 7 breeds studied predicted variations from +39.62 to +43.14 D in IOL powers necessary to approximate emmetropia. Results of the study support the routine use of canine IOL with dioptric strength of approximately +41.5 D in circumstances in which preoperative biometry and keratometry are not practical. The findings further suggest that, for the specific population of dogs studied, most of the dogs could be corrected to near emmetropia by use of a small range of IOL dioptric strengths, irrespective of body type or breed.
显示更多 [+] 显示较少 [-]Use of biometry and keratometry for determining optimal power of intraocular lens implants in dogs
1991
Gaiddon, J. | Rosolen, S.G. | Steru, L. | Cook, C.S. | Peiffer, R. Jr
Axial length and corneal curvature were determined by use of A-scan ultrasonography and keratometry on both eyes of dogs of various breeds, sizes, and ages. Mean axial length was 20.43 +/- 1.48 mm; axial length was not related to age or sex, but was significantly greater (P = 0.047) in dogs of larger breeds. Mean corneal curvature was 39.94 +/- 2.61 diopters. Dogs of large breeds had significantly (P < 0.001) flatter corneas. Mild, roughly symmetric astigmatism was detected in a majority of dogs. Use of mean values in a theoretic artificial intraocular lens power equation suggests that aphakic dogs require an implant of approximately 40 diopters to achieve emmetropia.
显示更多 [+] 显示较少 [-]Effects of tibial plateau angle and spacer thickness applied during in vitro canine total knee replacement on three-dimensional kinematics and collateral ligament strain 全文
2014
Baker, Katherine M. | Foutz, Timothy L. | Johnsen, Kyle J. | Budsberg, Steven C.
Objective—To quantify the 3-D kinematics and collateral ligament strain of stifle joints in cadaveric canine limbs before and after cranial cruciate ligament transection followed by total knee replacement (TKR) involving various tibial plateau angles and spacer thicknesses. Sample—6 hemi-pelvises collected from clinically normal nonchondrodystrophic dogs (weight range, 25 to 35 kg). Procedures—Hemi-pelvises were mounted on a modified Oxford knee rig that allowed 6 degrees of freedom of the stifle joint but prevented mechanical movement of the hip and tarsal joints. Kinematics and collateral ligament strain were measured continuously while stifle joints were flexed. Data were again collected after cranial cruciate ligament transection and TKR with combinations of 3 plateau angles (0°, 4°, and 8°) and spacer thicknesses (5, 7, and 9 mm). Results—Presurgical (ie, normal) stifle joint rotations were comparable to those previously documented for live dogs. After TKR, kinematics recorded for the 8°, 5-mm implant most closely resembled those of unaltered stifle joints. Decreasing the plateau angle and increasing spacer thickness altered stifle joint adduction, internal rotation, and medial translation. Medial collateral ligament strain was minimal in unaltered stifle joints and was unaffected by TKR. Lateral collateral ligament strain decreased with steeper plateau angles but returned to a presurgical level at the flattest plateau angle. Conclusions and Clinical Relevance—Among the constructs tested, greatest normalization of canine stifle joint kinematics in vitro was achieved with the steepest plateau angle paired with the thinnest spacer. Furthermore, results indicated that strain to the collateral ligaments was not negatively affected by .
显示更多 [+] 显示较少 [-]Mechanical properties of isolated loops of nylon leader material, polyethylene cord, and polyethylene tape and mechanical properties of those materials secured to cadaveric canine femurs via lateral femoral fabellae, toggles placed through bone tunnels, or bone anchors 全文
2012
Objective: To determine mechanical properties of various prosthetic materials secured to cadaveric canine femurs via various methods and to compare results with those for isolated loops of prosthetic material. Sample: 80 femurs obtained from cadavers of skeletally mature large-breed dogs. Procedures: 10 femoral constructs in each of 8 groups (single circumfabellar loop of polyethylene cord, double loop of polyethylene tape secured via a bone anchor [BAPT], single or double circumfabellar loops of nylon leader material [CNL] or polyethylene tape [CPT], or single or double loops of polyethylene tape secured via a toggle placed through a bone tunnel [BTPT]) and 10 isolated loops of prosthetic material in each corresponding configuration were tested. Stress relaxation, creep, elongation, load at 3 mm of displacement, stiffness, and peak load at failure were determined. Results: 5 single CNL constructs failed before completion of testing. Double CNL and single circumfabellar polyethylene cord constructs had the lowest loads at 3 mm of displacement. Single and double CPT constructs had the highest stiffness. Double BTPT and CPT constructs had the highest peak loads at failure. Double BTPT, double CPT, and BAPT constructs were mechanically superior on the basis of lower creep and stress relaxation and higher stiffness and load at 3 mm of displacement versus other constructs. Stiffness of femoral constructs was 28% to 69% that of corresponding isolated prosthetic loops. Conclusions and Clinical Relevance: Double BTPT, double CPT, and BAPT constructs were mechanically superior to other constucts. Mechanical properties and methods of anchorage and securing of free ends of prostheses contributed to mechanical properties of constructs.
显示更多 [+] 显示较少 [-]Absence of bactericidal effect of focused shock waves on an in-vitro biofilm model of an implant 全文
2012
Madron, Matthew S. | McClure, Scott R. | Griffith, Ronald W. | Wang, Chong
The objective of this study was to evaluate the bactericidal effect of shock waves (SWs) on gram-negative or gram-positive monocultured biofilms grown on an orthopedic implant in vitro. Cortical bone screws were individually cultured with Escherichia coli or Staphylococcus epidermidis to produce a biofilm. In each run of 8 screws, 6 screws were treated with shock waves and then sonicated to disrupt the biofilm. One screw was sonicated only and one was not shock waved or sonicated before sampling for plate count dilutions. Post-treatment serial dilutions and plate counts were done on an aliquot from the vial containing each screw to obtain the number of colony-forming units (CFUs). Shock waves were at a constant energy of 0.15 mJ/mm2. Pulse number and screw orientation were varied. A linear mixed-effects model was used with “treatment” as a fixed effect and “run” as a random effect. Pairwise comparisons of treatments were performed with Tukey-Cramer’s adjustment for P-values. Sonicated plate counts were greater than nonsonicated counts for each run. When all sonicated screws were compared to all nonsonicated screws, the counts were significantly increased (P = 0.0091). For each paired comparison between sonicated and shock wave treatment, the only significant difference was in the S. epidermidis biofilm treated at 2000 pulses in a horizontal position, which increased the post-treatment count (P = 0.0445). No bactericidal effects were seen on monocultured biofilms on cortical bone screws treated with shock waves.
显示更多 [+] 显示较少 [-]