细化搜索
结果 1-7 的 7
Impact of early castration and health status on the performance of Holstein-Friesian and beef crossbred calves
2016
Wielgosz-Groth, Zofia | Sobczuk-Szul, Monika | Nogalski, Zenon | Purwin, Cezary | Pogorzelska-Przybyłek, Paulina | Winarski, Rafał
Introduction: This article presents the analysis of the correlation between the category and health status of calves and the results of their rearing and levels of selected blood parameters.Material and Methods: The study included 105 Polish Holstein-Friesian and beef (Limousine, Charolaise and Hereford) crossbred calves. Young bulls were purchased at the age of two to four weeks. The animals underwent quarantine, were dehorned, and 46 young bulls were castrated. The germ horns were removed by burning out. Castration was carried out with a bloodless method using a rubber band. The calves were kept in groups and fed a milk replacer administered via teats from automated milk-feeding stations. After the period of milk feeding, the calves were fed grass silage ad libitum and a concentrate at 2.5 kg/animal/day. The calves were weighed every two weeks. Blood for analyses was sampled at 43 d of age.Results: After the rearing period finished at the age of six months, young bulls and steers had similar body weights (176.17 and 176.55 kg) and approximate average daily weight gains from birth (0.756 and 0.767 g/day). The healthy calves at six months of age weighed 180.47 kg, whereas the animals which at least once suffered from some diseases during rearing were lighter by approx. 30 kg (P ≤ 0.01). A statistically significant (P ≤ 0.01) difference was found for the count of red blood cells and white blood cells. In comparison with healthy individuals, the diseased animals had less RBC (8.33 and 9.42 10¹²/L respectively) and more WBC (27.03 and 12.26 10⁹/L respectively).Conclusion: Castration of young bulls did not have any impact on the results of rearing and health status of the calves. The magnitude of the analysed parameters depended on the health status of the calves. Thus RBC and WBC parameters may be used to predict the health status of calves during rearing.
显示更多 [+] 显示较少 [-]Identification of a free skin flap from the region vascularized by the deep circumflex iliac artery of horses
1990
Lees, M.J. | Bowen, C.V. | Fretz, P.B. | Leach, D.H.
Areas of skin vascularized by large axial vessels potentially suitable for microvascular anastomosis were investigated in 10 horse cadavers. Eleven such areas were dissected, and the skin over the flank region vascularized by the deep circumflex iliac artery was most suitable. The anatomy of this area was further defined, using angiography and latex injection studies on 10 cadavers.
显示更多 [+] 显示较少 [-]Pharmacokinetics and efficacy of trazodone following rectal administration of a single dose to healthy dogs
2020
O'Donnell, Erica M. | Press, Saya A. | Karriker, Margo J. | Istvan, Stephanie A.
OBJECTIVE To determine the pharmacokinetics and efficacy of trazodone following rectal administration of a single dose to healthy dogs. ANIMALS 6 healthy adult dogs. PROCEDURES Each dog received a single dose of trazodone (approx 8 mg/kg) per rectum. Trazodone tablets were crushed into a powder, mixed with 5 mL of tap water, and injected into the rectum via a red rubber catheter. Sedation scores were assigned, and blood samples were collected for determination of plasma trazodone concentration at predetermined times before and after drug administration. Pharmacokinetic parameters were estimated by noncompartmental analysis. RESULTS Plasma trazodone concentration remained below the detection limit for 1 dog even though it became moderately sedate. Median (interquartile [25th to 75th percentile] range [IQR]) maximum plasma trazodone concentration and volume of distribution and clearance corrected for bioavailability were 1.00 μg/mL (0.66 to 1.40 μg/mL), 10.3 L/kg (7.37 to 14.4 L/kg), and 639 mL/kg/h (594 to 719 mL/kg/h), respectively. Median time to maximum plasma trazodone concentration and elimination half-life were 15 minutes (range, 15 to 30 minutes) and 12 hours (IQR, 7.99 to 12.7 hours), respectively. All dogs became mildly or moderately sedate, and the extent of sedation was maximal at a median of 30 minutes (IQR, 30 to 60 minutes) after trazodone administration. No adverse effects were observed. CONCLUSIONS AND CLINICAL RELEVANCE Rectal administration of trazodone may be a viable option for sedation and treatment of anxiety in dogs for which administration of sedatives and anxiolytics by other routes is contraindicated. Further research is necessary to better elucidate the pharmacokinetics and efficacy of trazodone following rectal administration and determine optimal dosing.
显示更多 [+] 显示较少 [-]Accuracy of tidal volume delivery by five different models of large-animal ventilators
2020
Floriano, Dario | Hopster, Klaus | Driessen, Bernd
OBJECTIVE To determine the accuracy of tidal volume (VT) delivery among 5 different models of large-animal ventilators when tested at various settings for VT delivery, peak inspiratory flow (PIF) rate, and fresh gas flow (FGF) rate. SAMPLE 4 different models of pneumatically powered ventilators and 1 electrically powered piston-driven ventilator. PROCEDURES After a leak flow check, each ventilator was tested 10 times for each experimental setting combination of 5 levels of preset VT, 3 PIF rates, and 4 FGF rates. A thermal mass flow and volume meter was used as the gold-standard method to measure delivered VT. In addition, circuit systems of rubber versus polyvinyl chloride breathing hoses were evaluated with the piston-driven ventilator. Differences between preset and delivered VT (volume error [ΔVT]) were calculated as a percentage of preset VT, and ANOVA was used to compare results across devices. Pearson correlation coefficient analyses and the coefficient of determination (r2) were used to assess potential associations between the ΔVT and the preset VT, PIF rate, and FGF rate. RESULTS For each combination of experimental settings, ventilators had ΔVT values that ranged from 1.2% to 22.2%. Mean ± SD ΔVT was 4.8 ± 2.5% for the piston-driven ventilator, compared with 6.6 ± 3.2%, 10.6 ± 2.9%, 13.8 ± 2.97%, and 15.2 ± 2.6% for the 4 pneumatic ventilators. The ΔVT increased with higher PIF rates (r2 = 0.69), decreased with higher FGF rates (r2 = 0.62), and decreased with higher preset VT (r2 = 0.58). CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that the tested ventilators all had ΔVT but that the extent of each of ΔVT varied among ventilators. Close monitoring of delivered VT with external flow and volume meters is warranted, particularly when pneumatic ventilators are used or when very precise VT delivery is required.
显示更多 [+] 显示较少 [-]Comparison of bronchoscopic and nonbronchoscopic bronchoalveolar lavage in healthy cats
2018
Hooi, Kimberly S. | Defarges, Alice M. | Sanchez, Andrea L. | Nykamp, Stephanie G. | Weese, J Scott | Abrams-Ogg, Anthony C. G. | Bienzle, Dorothee
OBJECTIVE To compare bronchoalveolar lavage (BAL) accomplished by use of a bronchoscopic (B-BAL) and a nonbronchoscopic (NB-BAL) technique in healthy cats. ANIMALS 12 healthy cats. PROCEDURES Two BALs were performed in a randomized order 2 weeks apart in each cat. Cats were anesthetized, and a 2.9-mm fiberoptic bronchoscope (B-BAL) or 8F red rubber catheter (NB-BAL) was wedged in a bronchus. Two 5-mL aliquots of saline (0.9% NaCl) solution were infused into the left and right caudal lung fields and aspirated manually with a 20-mL syringe. Proportion of BAL fluid (BALF) retrieved, depth of wedging, and anesthetic complications were recorded. Total nucleated cell count, differential cell count, and semiquantitative scores of cytologic slide quality were determined for all BALF samples. Results were compared with ANOVAs and Wilcoxon signed rank tests. RESULTS Proportion of retrieved BALF and depth of wedging were significantly greater for B-BAL than NB-BAL. Differential cell counts and cytologic slide quality did not differ significantly between techniques. Complications included transient hemoglobin desaturation (24/24 [100%] BALs) and prolonged anesthetic recovery time (4/24 [17%] BALs). Anesthetic recovery scores did not differ significantly between techniques. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that NB-BAL was noninferior to B-BAL with regard to ease of performance, anesthetic variables, and cytologic slide quality for cats without clinical respiratory tract disease.
显示更多 [+] 显示较少 [-]In vitro evaluation of negative pressure generated during application of negative suction volumes by use of various syringes with and without thoracostomy tubes
2019
Mezzles, Marguerite J. | Murray, Rebecca L. | Heiser, Brian P.
OBJECTIVE To determine the amount of negative pressure generated by syringes of various sizes with and without an attached thoracostomy tube and whether composition of thoracostomy tubes altered the negative pressure generated. SAMPLE Syringes ranging from 1 to 60 mL and 4 thoracostomy tubes of various compositions (1 red rubber catheter, 1 polyvinyl tube, and 2 silicone tubes). PROCEDURES A syringe or syringe with attached thoracostomy tube was connected to a pneumatic transducer. Each syringe was used to aspirate a volume of air 10 times. Negative pressure generated was measured and compared among the various syringe sizes and various thoracostomy tubes. RESULTS The negative pressure generated decreased as size of the syringe increased for a fixed volume across syringes. Addition of a thoracostomy tube further decreased the amount of negative pressure. The red rubber catheter resulted in the least amount of negative pressure, followed by the polyvinyl tube and then the silicone tubes. There was no significant difference in negative pressure between the 2 silicone tubes. The smallest amount of negative pressure generated was −74 to −83 mm Hg. CONCLUSIONS AND CLINICAL RELEVANCE Limited data are available on the negative pressure generated during intermittent evacuation of the thoracic cavity. For the present study, use of a syringe of ≥ 20 mL and application of 1 mL of negative suction volume resulted in in vitro pressures much more negative than the currently recommended pressure of −14.71 mm Hg for continuous suction. Additional in vitro or cadaveric studies are needed.
显示更多 [+] 显示较少 [-]Population pharmacokinetics of a single dose of meloxicam after oral and intramuscular administration to captive lesser flamingos (Phoeniconaias minor)
2016
Zordan, Martin A. | Papich, Mark G. | Pich, Ashley A. | Unger, Katy M. | Sanchez, Carlos R.
OBJECTIVE To determine the pharmacokinetics of a single dose of meloxicam after IM and oral administration to healthy lesser flamingos (Phoeniconaias minor) by use of a population approach. ANIMALS 16 healthy captive lesser flamingos between 1 and 4 years of age. PROCEDURES A single dose of meloxicam (0.5 mg/kg) was administered IM to each bird, and blood samples were collected from birds at 3 (n = 13 birds), 2 (2), or 1 (1) selected point between 0 and 13 hours after administration, with samples collected from birds at each point. After a 15-day washout period, the same dose of meloxicam was administered PO via a red rubber tube and blood samples were collected as described for IM administration. Pharmacokinetic values were determined from plasma concentrations measured by high-performance liquid chromatography. RESULTS Plasma drug concentrations after IM administration of meloxicam reached a mean ± SD maximum value of 6.01 ± 3.38 μg/mL. Mean area under the concentration-versus-time curve was 17.78 ± 2.79 μg•h/mL, and mean elimination half-life was 1.93 ± 0.32 hours. Plasma concentrations after oral administration reached a mean maximum value of 1.79 ± 0.33 μg/mL. Mean area under the curve was 22.16 ± 7.17 μg•h/mL, and mean elimination half-life was 6.05 ± 3.53 hours. CONCLUSIONS AND CLINICAL RELEVANCE In lesser flamingos, oral administration of meloxicam resulted in higher bioavailability and a longer elimination half-life than did IM administration, but the maximum plasma concentration was low and may be insufficient to provide analgesia in flamingos. Conversely, IM administration achieved the desired plasma concentration but would require more frequent administration.
显示更多 [+] 显示较少 [-]