细化搜索
结果 1-6 的 6
Effect of additional human chorionic gonadotrophin (hCG) on follicular growth and ovulation in gonadotrophin-treated gilts
2015
Manjarin, Rodrigo | Cassar, Glen | Friendship, Robert M. | Garcia, Jose C. | Dominguez, J Carlos | Kirkwood, Roy N.
The objective of this study was to determine the effect of additional human chorionic gonadotrophin (hCG) on the ovarian response of gilts previously treated with 200 IU hCG combined with 400 IU equine chorionic gonadotrophin (eCG) (eCG/hCG). Seventy-one prepuberal gilts (105 ± 7.5 kg) were assigned to groups: i) eCG/hCG (hCG-0; n = 25); ii) eCG/hCG followed by 100 IU of hCG at 24 h (hCG-100; n = 24); iii) eCG/hCG followed by 200 IU hCG at 24 h (hCG-200; n = 10); and iv) controls (CON; n = 12). Ovulation response was assessed by ovarian dissection or real-time ultrasonography. Additional hCG did not significantly improve numbers of gilts ovulating. Numbers of corpora lutea increased with hCG, and was higher in hCG-200 (P < 0.01). Compared to hCG-0, the frequency of cysts in gilts was higher in hCG-100 (P < 0.05) and further increased in hCG-200 (P < 0.01). The number of cysts per gilt was dose-dependently increased by additional hCG. We conclude that supplemental hCG will increase the number of corpora lutea but will be associated with follicular cyst development in a dose dependent manner.
显示更多 [+] 显示较少 [-]Relationship between intracranial pressure as measured by an epidural intracranial pressure monitoring system and optic nerve sheath diameter in healthy dogs
2015
llie, Laura A. | Thomovsky, Elizabeth J. | Johnson, Paula A. | Bentley, Tim | Heng, Hock Gan | Lee, Hee C. | Moore, George E.
OBJECTIVE To evaluate the association between ultrasonographically measured optic nerve sheath diameter (ONSD) and acute increases in intracranial pressure (ICP) as measured by an epidural intracranial pressure monitoring system (EICPMS) in healthy dogs. ANIMALS 6 young healthy dogs. PROCEDURES An EICPMS connected to a pressure monitor was used to generate a continuous pressure waveform in each anesthetized dog. A 22-gauge IV catheter was inserted into the brain parenchyma through the contralateral parietal bone, and 0.5 to 2.0 mL of anticoagulated autologous blood was injected at predetermined intervals. At baseline (immediately after EICPMS placement) and following each injection, the ICP as indicated by EICPMS was recorded, and 3 ultrasonographic images of the optic nerve sheath of each eye were obtained. The ONSD was measured at maximum diameter and at 5 mm caudal to the optic disk. RESULTS In linear models, the maximum ONSD was positively associated with increasing ICP. Specifically, the rate of maximum ONSD increase was greater for pressures ≤ 20 mm Hg above baseline (0.0534 mm/1 mm Hg ICP increase) than for pressures > 40 mm Hg above baseline (0.0087 mm/1 mm Hg ICP increase). The relationship of ICP to maximum ONSD was slightly nonlinear and best explained by comparison of fractional polynomial regression models. CONCLUSIONS AND CLINICAL RELEVANCE ICP was positively and nonlinearly associated with increasing maximum ONSD, especially when ICP was ≤ 20 mm Hg above baseline, supporting the conclusion that ultrasonographic measurement of maximum ONSD may provide a noninvasive monitoring tool for evaluation of ICP in dogs. Further research is needed to assess the utility of these measurements in clinical patients.
显示更多 [+] 显示较少 [-]Comparison of ultrasound biomicroscopy and standard ocular ultrasonography for detection of canine uveal cysts
2015
Taylor, LaTisha N. | Townsend, Wendy M. | Heng, Hock Gan | Stiles, Jean | Moore, George E.
OBJECTIVE To compare ultrasound biomicroscopy (UBM) with standard ocular ultrasonography for detection of canine uveal cysts and to determine the sensitivity, specificity, and interobserver agreement for detection of uveal cysts with UBM. SAMPLE 202 enucleated eyes from 101 dogs. PROCEDURES 2 examiners examined 202 eyes by means of UBM (50 MHz) to identify uveal cysts. A board-certified radiologist then examined 98 of the 202 eyes by means of standard ocular ultrasonography (7- to 12-MHz linear transducer). Subsequently, 1 examiner dissected all 202 eyes under magnification from an operating microscope to definitively identify uveal cysts. Each examiner was masked to other examiners’ findings. Sensitivity, specificity, and interobserver agreement were calculated for detection of cysts by UBM. RESULTS Cysts were detected by use of UBM in 55 of 202 (27%) eyes by one examiner and 29 of 202 (14%) eyes by the other. No cysts were detected in the 98 eyes examined with standard ocular ultrasonography. Dissection results revealed that cysts were present in 64 of 202 (32%) eyes, including 29 of 98 (30%) eyes examined by standard ocular ultrasonography. Mean sensitivity of UBM for cyst detection was 47%; mean specificity was 92%. Uveal cysts not identified with UBM were often small (mean diameter, 490 üm). Interobserver agreement was high (κP = 0.81). CONCLUSIONS AND CLINICAL RELEVANCE UBM was more effective than standard ocular ultrasonography for detection of uveal cysts in enucleated eyes. Small-diameter cysts were difficult to visualize even with UBM.
显示更多 [+] 显示较少 [-]Development of a model to induce transient synovitis and lameness in the hip joint of dogs
2015
Hassan, Elham A. | Lambrechts, Nicolaas E. | Moore, George E. | Weng, Hsin-Yi | Heng, Hock Gan | Breur, Gert J.
OBJECTIVE To develop a model of hip joint synovitis on the basis of intra-articular injection of a sodium urate suspension in dogs and to characterize associated gait changes. ANIMALS 6 healthy adult dogs. PROCEDURES Each dog was sedated, and synovitis was induced by injection of 1 mL of a sodium urate suspension (20 mg/mL) into the right hip joint under ultrasonographic guidance. Observational and instrumented gait analyses to determine temporospatial, kinetic, and kinematic variables were performed prior to and 4, 8, and 24 hours after sedation and synovitis induction. RESULTS Injection of a sodium urate suspension into the hip joint of healthy dogs resulted in lameness of the ipsilateral pelvic limb as determined by observational and instrumented gait analyses. For all dogs, lameness was clinically detectable within 1.5 to 2 hours after injection, reached its maximum intensity at 4 hours after injection, and had subsided by 24 hours after injection. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that injection of a sodium urate suspension into the hip joint of healthy dogs reliably induced synovitis and signs of pain and lameness in the ipsilateral pelvic limb that lasted 24 hours. This model can be used in conjunction with instrumented gait analysis to provide information on gait changes associated with hip joint disease and might be useful for evaluating the efficacy of analgesics or other interventions for the treatment of hip joint disease in dogs.
显示更多 [+] 显示较少 [-]Ultrasonographic detection of early atrophy of the intrinsic laryngeal muscles of horses
2015
Chalmers, Heather J. | Viel, Laure | Caswell, Jeff L. | Ducharme, N. G. (Norman Guy)
OBJECTIVE To describe the ultrasonographic changes in the cricoarytenoideus dorsalis (CAD) and cricoarytenoideus lateralis (CAL) muscles of horses before and at various times during the 32 weeks after unilateral neurectomy of the right recurrent laryngeal nerve. ANIMALS 28 healthy Standardbreds. PROCEDURES For each horse, the appearance of the CAD and CAL muscles on the right (neurectomized) and left (control) sides was serially monitored ultrasonographically by percutaneous (CAD and CAL) and transesophageal (CAD) approaches. The ultrasonographic images were assessed to determine the mean pixel intensity, muscle thickness, and appearance grade, and comparisons were made between the muscles of the neurectomized and control sides. RESULTS The muscle appearance grade and mean pixel intensity for the CAL and CAD muscles on the neurectomized side were significantly increased by 2 and 4 weeks, respectively, after the neurectomy. The transesophageal approach enhanced the ultrasonographic visibility of the CAD muscle and allowed us to detect a significant decrease in the thickness of the CAD muscle on the neurectomized side over time, compared with thickness of the CAD muscle on the control side. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested ultrasonography can be used to successfully assess the CAL and CAD muscles of horses. A qualitative grading scheme was sufficient for successful detection and monitoring of muscle atrophy and reduced the need for image standardization. The transesophageal approach described for assessment of the CAD muscle warrants further investigation.
显示更多 [+] 显示较少 [-]The follicle characteristic and immature oocyte quality obtained from repeated transvaginal oocyte retrieval in Bos indicus beef cows
2015
Izuan Bahtiar A. J. | Ahmad J. | Saadiah J. | Azizah A. | Ahmad Nazri A. R.
The development and availability of follicles is an indicator to predict which of the follicle sizes are suitable to recover the oocytes assisted by means of ultrasonography of transvaginal oocyte retrieval (OPU). Thus, the study was done in order to characterize the follicular recruitment and distribution in response to the repeated removal of follicles, and thus to determine the availability of follicles and immature oocytes harvested repeatedlyfor two consecutive days of OPU in beef cows. Results indicated that 24-h OPU showed significantly greater numbers of medium and large follicles than small categories (P<0.05). However the 48-hr of OPU does not showed any differences of follicles categories (P>0.05). The mean total number of follicles and immature oocytes recovered were higher (P<0.05) in 24-hr OPU (13.76±1.2 and 7.38 ± 1.7) compared to 48-hr OPU (9.08 ± 1.5 and 3.54 ± 1.00) with the oocyte retrieval rate of 51.22% and 38.17%, respectively. The morphological classification indicated the 24-hr oocyte retrieval produced 62% of suitable immature oocytes that can be used for in vitro embryo production. In conclusion, the repeated removal of two consecutive days of OPU has averted the development of dominant follicle, and thus, gave an atmosphere to the subordinate follicles to continue growth relatively to an equal proportion of small, medium and large categories of follicles. Due to the reduction of follicle and recovery rate at 48-hr it is suggested that OPU be carried out later than 48 hour so that the follicle has more time to increase the diameter size.
显示更多 [+] 显示较少 [-]