细化搜索
结果 1-10 的 31
Groundwater Quality Protection : A Guide for Water Utilities, Municipal Authorities, and Environment Agencies | Protecao da qualidade da agua subterranea um guia para empresas de abastecimento de agua, orgaos municipais e agencias ambientais Proteccion de la calidad del agua subterranea : guia para empresas de agua, autoridades municipales y agencias ambientales 全文
2002
Foster, Stephen | Hirata, Ricardo | Gomes, Daniel | D'Elia, Monica | Paris, Marta
This publication provides guidance to water-sector decision makers and planners on how to deal with the quality dimension of groundwater resources management in the World Bank's client countries. There is growing evidence of increasing pollution threats to groundwater and some well-documented cases of irreversible damage to important aquifers. This guide has been produced in the belief that groundwater pollution hazard assessment must become an essential part of environmental best practice for water supply utilities. The guide is particularly relevant for the World Bank's Latin American and Caribbean Region, where many countries have initiated major changes to modernize their institutional and legal framework for water resources management, but may not yet have considered groundwater at the same level as surface water, because of lack of awareness and knowledge of groundwater issues and policy options.
显示更多 [+] 显示较少 [-]Efeito da cloração orgânica na uniformidade de distribuição de água em sistema de irrigação por gotejamento utilizando água ferruginosa | Effect of the organic chlorination in the uniformity of water distribution in system of irrigation for dripping using water high in iron content 全文
2007
Martins, Cristiani Campos | http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4779715U1 | Reis, Edvaldo Fialho dos | http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4782868H7 | Soares, Antonio Alves | http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4787014Z2 | Leal, Brauliro Gonçalves | http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4784843E5 | Ferreira, Paulo Afonso | http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4783301T5 | Martinez, Mauro Aparecido | http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4781072U1
Com o aumento em área da irrigação localizada no Brasil, começaram a vir a público problemas de perda de desempenho de equipamentos, em regiões com águas superficiais com elevados teores de ferro total, como o norte do Espírito Santo. O objetivo do presente trabalho foi: avaliar o desempenho de sistemas de irrigação por gotejamento utilizados na irrigação com água ferruginosa, verificar a eficiência do tratamento químico com dicloroisocianurato de sódio (65%) na prevenção do entupimento e identificar as ferrobactérias causadoras da obstrução de gotejadores. Este trabalho foi realizado em uma área experimental na escola Agrotécnica Federal de Santa Teresa, Espírito Santo. Para avaliar o efeito da cloração orgânica na uniformidade de distribuição de água e na vazão de três modelos de tubogotejadores (M1; M2 e M3) foram testados quatro concentrações de cloro livre: nível N1 (sem aplicação de cloro), nível N2 (15 mg L-1 de cloro livre), nível N3 (30 mg L-1 de cloro livre) e nível N4 (45 mg L-1 de cloro livre). As avaliações foram realizadas no início do experimento e a cada 100 horas de funcionamento do sistema, totalizando 8 avaliações. O produto foi aplicado por uma hora, após cada avaliação de uniformidade. No final do experimento, foram retiradas amostras dos tubogotejadores para identificar a presença de ferrobactérias causadoras de entupimento. Após 700 horas de funcionamento, na subunidade de irrigação que não recebeu o tratamento com o dicloro (N1), os valores do CUC, CUD, Us e da vazão do tubogotejador M1 reduziram de: 23; 30,2; 28,35 e 26,13%, respectivamente; e para o modelo M2 as reduções foram de 12,3; 19,5; 16,25 e 27,4%, respectivamente. Para o modelo M3 ocorreram reduções no CUC, CUD e Us de 8,2; 15,17; 12,5%, entretanto, a vazão, diferentemente dos outros modelos, sofreu um incremento de 1%. O CVq no nível N1, apresentou aumento na variação para os três tubogotejadores. Os distintos tratamentos com dicloro (N2, N3 e N4) foram eficientes na prevenção de entupimento. Os tubogotejadores M1 e M3 apresentaram tendência em manter vazões constantes em todas as avaliações. Os três modelos de tubogotejadores apresentaram menores variações de vazão nas subunidades que receberam aplicação do cloro orgânico. Bactérias dos gêneros Gallionella e Leptpthrix foram encontradas nos tubogotejadores, constatando-se a presença de 1 a 10 filamentos por célula em todas as amostras analisadas. | With the increase of the irrigated area micro irrigation in Brazil, problems of loss of equipment performances came out, in regions with superficial waters with high total iron concentration, as the north of the State of Espírito Santo. The objective of the present work was to evaluate the performance of drip irrigation systems working with water high total iron content, to verify the efficiency of the chemical treatment with dicloroisocianurato of sodium (65%) in the clogging prevention and to identify the ironbacteria that causes the emitters clogging. This experiment was carried through at Escola Agrotécnica Federal de Santa Teresa, Espirito Santo. To evaluate the effect of the organic chlorination in the water distribution uniformity and the discharge of three models of tubedrippers (M1; M2 and M3), four levels chlorination was tested: level N1 (without chlorine application), level N2 (15 mg L-1 of free chlorine), level N3 (30 mg L-1 of free chlorine) and level N4 (45 mg L-1 of free chlorine). The evaluations were performed in the beginning of experiment and every 100 hours of operation, totalizing 8 evaluations. The product was applied by one hour, after each evaluation. At the end of the experiment, samples of the tubedrippers had been removed to identify the presence of causing ironbacteria of clogging. After 700 hours of operation, in the subunit with no dicloro treatment (level - N1); the values of CUC, CUD, US and the discharge for the tubedripper M1, reduced of 23; 30,2; 28,35 and 26,13%, respectively; for the model M2 the reductions the reductions were: 12,3; 19,5; 16,25 and 27.4%, respectively; and for the model - M3 the reductions in the values of CUC, CUD and US were 8,2; 15,17; 12,5%, respectively, however, differently from the other models, the discharge increased 1%. The CVq in the N1 level, it had an increase in the variation for the three tubedrippers. The distinct chloride treatments (N2, N3 and N4) were efficients to prevent clogging. The discharge for the tubedrippers M1 and M3 were more constant in the different evaluations. The three models of tubogotejadores presented lower discharge variations in the subunits treated with organic chlorine. The bacterias of the gender Gallionella and Leptpthrix were found in tubedrippers, presenting 1 the 10 filaments for cell in all the samples analysed. | Conselho Nacional de Desenvolvimento Científico e Tecnológico
显示更多 [+] 显示较少 [-]The influence of industrial and agricultural waste on water quality in the Água Boa stream (Dourados, Mato Grosso do Sul, Brazil) 全文
2015
da Rocha, Monyque Palagano | Dourado, Priscila Leocadia Rosa | de Souza Rodrigues, Mayara | Raposo, Jorge Luiz Jr | Grisolia, Alexeia Barufatti | de Oliveira, Kelly Mari Pires
Water quality monitoring is used to determine the impact of human activities on the environment. We evaluated water quality in the Água Boa stream, located within the municipality of Dourados, State of Mato Grosso do Sul, Brazil, by analyzing physico-chemical, chemical, and microbiological parameters, as well as chlorophyll concentrations. Five sets of water samples were collected between December 2012 and November 2013 from three locations within the stream. The results showed the presence of Escherichia coli and antibiotic-resistant Pseudomonas spp. strains and high concentrations of organic matter (total dissolved solids), inorganic species (Mg, Ca, and Fe), and agrochemical residues (thiamethoxam). The main stream water contaminants are derived from urban, industrial, and agricultural activities within the watershed. Given the presence of contaminants, it is important that such findings are disseminated in order to highlight the risks that contact with this water may pose to human health. To preserve the environment and improve site conditions, people would need to participate by demanding that normative national and international standards be respected and that the situation be supervised by the competent governmental agencies; this would make it possible to reverse or minimize contamination problems within the Água Boa stream.
显示更多 [+] 显示较少 [-]Potassium fertilization in rocket plants: production and efficiency in water use = Adubação potássica em plantas de rúcula: produção e eficiência no uso da água
2013
Porto, Rebeca de Andrade | Bonfim-Silva, Edna Maria | Débora Santana de Matos Souza | Cordova, Norman Ruddel Mendez | Polyzel, Analy Castilho | Tonny José Araújo da Silva
The rocket (Euruca sativa) is an important vegetable in human´s feed and one of the most nutritious, rich in minerals such as potassium, sulfur and iron, and vitamins A and C. Since the late 90’s the rocket is gaining more market, with an increase in quantity sold, and its area planted. The aim for this study is to assess the effect of potassium on the yield characteristics, SPAD reading and efficiency in water use by plants of rocket. The experiment was conducted in a greenhouse during May-June 2011. The experimental plot consisted of vase built by PET 2.5 liter bottle with a capacity of 1 dm-3 of soil, using a wool wick for irrigation by capillary. The experimental design was completely randomized and its treatments consisted of six doses ofK2O: 0; 50; 100; 150; 200 and 250 mg dm-3 and using as source KCl and six replications. The variables analyzed were SPAD readings, leaf number, fresh mass, dry mass, root dry mass and water use efficiency. The potassium fertilization increases the SPAD reading and water use efficiency by rocket plants in potassium doses of 156.4 and 200 mg dm-3, respectively. Variables fresh and dry mass of plants are influenced by potassium fertilization with adjust of linear regression model. Variables number of leaves and root dry weight are not influenced by potassium fertilization.ResumoA rúcula (Euruca sativa) é uma hortaliça relevante na alimentação humana sendo uma das mais nutritivas, ricas emminerais como potássio, enxofre e ferro, além das vitaminas A e C. Desde o final da década de 90 a rúcula vem conquistandomercado com um aumento na quantidade comercializada e na sua área de plantio. Objetivou-se pelo presente estudo avaliaro efeito de doses de potássio nas características produtivas, leitura SPAD e eficiência no uso da água por plantas de rúcula.O experimento foi realizado em casa de vegetação no período de maio a junho de 2011. A parcela experimental consistiu devaso construído por garrafa PET de 2,5 litros, com capacidade para 1 dm-3 de solo, utilizando-se pavio de lã para irrigação porcapilaridade. O delineamento experimental foi inteiramente casualizado cujos tratamentos consistiram de seis doses de K2O: 0;50; 100; 150; 200 e 250 mg dm-3 utilizando-se como fonte o KCl e seis repetições. As variáveis analisadas foram leitura SPAD,número de folhas, massa fresca e massa seca da parte aérea, massa seca da raiz e eficiência no uso da água. A adubação compotássio aumenta a leitura SPAD e a eficiência no uso de água por plantas de rúcula nas doses de potássio de 156,4 e 200 mg dm-3,respectivamente. As variáveis massas fresca e seca de plantas são influenciadas pela adubação potássica com ajuste a modelolinear de regressão. As variáveis número de folhas e massa seca de raiz não são influenciadas pela adubação potássica.
显示更多 [+] 显示较少 [-]Aplicação de hipoclorito de sódio para recuperação de gotejadores entupidos em irrigação com água ferruginosa Application of sodium hypoclorite for recovery of clogged emitters working with ferruginous water 全文
2006
José A. A. de Souza | Élio de A. Cordeiro | Édio L. da Costa
O entupimento dos emissores é o maior problema do sistema de irrigação localizada. Geralmente, esta obstrução causa tanto redução quanto aumento da sua vazão, porém sempre se dá diminuição da uniformidade de distribuição de água do sistema, fato que pode ser minimizado pela aplicação de produtos químicos. O objetivo com este trabalho foi avaliar a aplicação de doses de cloro (50, 100 e 150 mg de cloro livre L-1 de água, T1, T2 e T3, respectivamente) na recuperação da vazão nominal (QN) de gotejadores Netafin-Ram 17, que apresentavam vazão média (QM) superior à QN, em razão de entupimentos ocorridos em dois anos de irrigação com água contendo 1,7 mg L-1 de ferro total. Avaliou-se a recuperação da QN e a uniformidade de distribuição de água dos gotejadores. A QN dos gotejadores era de 2,3 L h-1. Foram realizadas quatro aplicações em cada dose. A vazão média dos gotejadores decresceu gradativamente em todas as doses aplicadas com o aumento do número de aplicações. Os melhores resultados foram alcançados na dosagem de 150 mg L-1, na qual se alcançou a vazão nominal.<br>Clogging is a serious problem in trickle irrigation. Usually, this obstruction may cause decrease as well as increase of its discharge, but the water distribution uniformity of system always decreases due to clogging problems. These problems can be reduced by application of chlorine and acids. This work aimed to evaluate application of three concentrations (treatments) of sodium hypoclorite (50, 100 and 150 mg L-1 of free chlorine, T1, T2 and T3, respectively) with four applications in order to recover Netafin-Ram 17 emitters that presented average discharge greater than the nominal one, due to clogging caused by irrigation with water presenting 1.7 mg L-1 of total iron during two years. The recovery of nominal discharge and the water distribution uniformity of the emitters were evaluated. The emitter nominal discharge was 2.3 L h-1. The mean discharge decreased gradually in all the concentrations with the increase in number of applications. The best results were obtained in the concentrations of 150 mg L-1, in which the nominal flow was attained.
显示更多 [+] 显示较少 [-]Eficacia de dos especies de macrofitas fitorremediadoras (eichornia crassipes –buchón de agua y lemna minor –lenteja de agua) en bioensayos con aguas residuales del Lago Balmoral Urbano, Villavicencio 全文
2022
Palomino Peredo, Kiara Margarita | Velosa Caicedo, Rodrigo Isaac | https://orcid.org/0000-0003-4316-1405 | https://scholar.google.es/citations?hl=es&user=yQnEuEQAAAAJ | https://scienti.minciencias.gov.co/cvlac/visualizador/generarCurriculoCv.do?cod_rh=0001057120 | Universidad Santo Tomás
El déficit de fuentes de agua limpias dada la presencia de contaminantes en el agua es una problemática ambiental no solo de nivel local, sino también regional y nacional en Colombia. Para contrarestar este problema, se han implementado diferentes sistemas de tratamiento de aguas incluyendo la fitoremediación. La intención de este estudio fue la de evaluar la capacidad fitoremediadora de dos especies de plantas acuáticas –Eichornia crassipes y Lemna minor – para remover dos contaminantes –nitrógeno amoniacal N-NH3 y hierro total Fe – a partir de aguas residuales del lago Balmoral producto de la actividad agroforestal y ganadera en áreas vecinas. A partir de muestras de agua residual, se realizó el montaje de 2 bioensayos, uno con 100 g de E. crassipes y otro con 20 g de L.minor, y se realizaron mediciones de los dos contaminantes cada 4-5 días por espacio de 1 mes. Adicionalmente, se estableció el grado de absorción de los 2 contaminantes a partir de la raíz de E. crassipes y hojas de L. minor por medio de la maceración de las partes de las plantas al inicio y al final de los bioensayos. Los resultados obtenidos resaltan en Eichornia crassipes su capacidad de absorción y acumulación de contaminantes (56.5% de N-NH3 y 47.1% de Fe total), y su alta reducción y remoción en el agua residual (95% de N-NH3 y 75.9% de Fe Total). Por el contrario, Lemna minor no fue en este estudio una planta eficiente en la reducción y remoción de contaminantes del agua residual (0.45% de N-NH3 y 45% de Fe total), con baja capacidad de bioacumulación (26.7% de N-NH3 y 11.3% de Fe total). Se destaca la alta capacidad fitoremediadora de E. crassipes similar a la reportada en otros estudios. Se realizan algunas recomendaciones para la implementación de un sistema de fitoremediación con macrófitas acuáticas en el lago Balmoral. | The deficit of clean water sources due to the presence of contaminants in the water is an environmental problem not only at the local level, but also at the regional and national level in Colombia. To counteract this problem, different water treatment systems have been implemented, including phytoremediation. The intention of this study was to evaluate the phytoremediation capacity of two species of aquatic plants – Eichornia crassipes and Lemna minor – to remove two contaminants –ammoniacal nitrogen N-NH3 and total iron Fe – from Balmoral Lake wastewater, product of agroforestry and livestock activity in neighboring areas. From residual water samples, 2 bioassays were set up, one with 100 g of E. crassipes and the other with 20 g of L. minor, and measurements of the two contaminants were made every 4-5 days for a period of 1 month. Additionally, the degree of absorption of the 2 contaminants from the root of E. crassipes and leaves of L. minor was established by maceration of the plant parts at the beginning and at the end of the bioassays. The results obtained highlight in Eichornia crassipes its capacity for absorption and accumulation of pollutants (56.5% of N-NH3 and 47.1% of total Fe), and its high reduction and removal in wastewater (95% of N-NH3 and 75.9% Total Fe). On the contrary, Lemna minor was not in this study an efficient plant in the reduction and removal of pollutants from wastewater (0.45% of N-NH3 and 45% of total Fe), with low bioaccumulation capacity (26.7% of N- NH3 and 11.3% of total Fe). The high phytoremediation capacity of E. crassipes is outstanding, which is similar to that reported in other studies. Some recommendations are made for the implementation of a phytoremediation system with aquatic macrophytes in Lake Balmoral. | Ingeniero Ambiental | http://www.ustavillavicencio.edu.co/home/index.php/unidades/extension-y-proyeccion/investigacion | Pregrado
显示更多 [+] 显示较少 [-]Niveles de hierro y manganeso en el agua potable de consumo publico de Madrid.
1993
Vidal Marin M. | Tenorio Sanz M.D. | Garcia Mata M.
Aplicação de cloro orgânico no tratamento de tubogotejador utilizado na irrigação com água ferruginosa 全文
2010
Martins, Cristiani Campos | Soares, Antônio Alves | Ramos, Márcio Mota | Reis, Edvaldo Fialho dos
Para avaliar o efeito da cloração orgânica na uniformidade de distribuição de água e na vazão de um tubogotejador com vazão de 2,2 L h-1, foram testados quatro níveis de concentrações de dicloroisocianurato de sódio (N1 = 0, N2 = 15, N3 = 30 e N4 = 45 mg L-1 de cloro livre). As avaliações foram realizadas no início do experimento e a cada 100 horas de funcionamento do sistema, totalizando 8 avaliações. No cálculo da uniformidade de aplicação de água foram utilizados os coeficientes de uniformidade de Christiansen (CUC), de distribuição (CUD) e de emissão (Us). Também se realizou o estudo da vazão e do coeficiente de variação da vazão (CVq). Verificouse que no nível N1 ocorreram reduções de 23; 30,2 e 8,35%, para o CUC, CUD e Us, respectivamente, sendo que a vazão apresentou uma redução de 6,13%, refletindo em um aumento do CVq. O tratamento com dicloro foi eficiente para precaver contra entupimento para todas as concentrações utilizadas e o sistema foi classificado com excelente uniformidade em praticamente todas as avaliações. | To evaluate the effect of the organic chlorination in the uniformity of water distribution and in the outflow of a tubedripper with 2,2 L h-1, had been tested four levels of concentrations of dicloroisocianurato of sodium (N1 = 0, N2 = 15, N3 = 30 e N4 = 45 mg L-1 of free chlorine). The evaluations had been carried through in the beginning of the experiment and to each 100 hours of functioning of the system, totalizing 8 evaluations. In the calculation of the uniformity of water application had been used the coefficients of uniformity of Christiansen (CUC), of distribution (CUD) and emission (Us). Also the study of the discharge and the coefficient of variation of the discharge (CVq). It was verified that in the level N1, reductions of 23; 30.2 and 8.35%, for the CUC, CUD and US, respectively. The discharge presented a 6.13% reduction, reflecting in an increase of the CVq. The treatment with dicloro was efficient to prevent against clogging for all the used concentrations and the system was classified with excellent uniformity in practically all the evaluations.
显示更多 [+] 显示较少 [-]Caracterización de parámetros microbiológicos y fisicoquímicos del sistema para producir agua desionizada tipo II, en una industria cosmética. | Characterization parameters microbiological and physicochemical water system to produce deionized type II in a cosmetic industry 全文
2013 | 2014
Londoño Gaitán, Olga Patricia | Ruiz Suárez, Erika Johana
Se realizo la caracterización del proceso de producción de agua tipo II para una industria cosmética, monitoreando 4 puntos de muestreos establecidos: Punto Cl2, Punto pretratamiento, Punto UV y Punto lateral o de proceso. Se adquirió un equipo Helix 70, que cuenta con ultrafiltración y osmosis inversa para obtención producto final que sea óptimo para las formulaciones cosméticas y la estabilidad de los productos elaborados. Se realizó seguimiento durante 6 meses, semanal por cada punto, obteniéndose resultados estables para los resultados microbiológicos y fisicoquimico. Para los parámetros microbiológicos: Recuento de Aerobios, Coliformes totales, E. Coli y Pseudomona. Se evaluaron los siguientes parámetros en fisicoquimico: pH, Conductividad, Dureza; Cl2, Fe total. Se estableció que el producto obtenido es conforme a las especificaciones y los datos registrados son consistentes para cada tipo de agua | We performed the characterization of the type II water production for cosmetic industry, monitoring four sampling points established: Cl2 Point, pretreatment Point, UV Point and process Point. It took a team Helix 70, with ultrafiltration and reverse osmosis to obtain final product that is optimal for the cosmetic and the stability of the products. Were followed for 6 months, weekly for each point, yielding stable results for microbiological and physicochemical results. For microbiological parameters: Aerobic Count, Total Coliforms, E. Coli and Pseudomonas. We assessed the following physicochemical parameters: pH, conductivity, hardness, Cl 2, total Fe. It was established that the product obtained is as specified and recorded data are consistent for each type of water
显示更多 [+] 显示较少 [-]Aplicação de cloro orgânico no tratamento de tubogotejador utilizado na irrigação com água ferruginosa = Application of the organic chlorination in the treatment of tubedripper used in the irrigation with water high in iron content 全文
2010
Cristiani Campos Martins | Antônio Alves Soares | Márcio Mota Ramos | Edvaldo Fialho dos Reis
Para avaliar o efeito da cloração orgânica na uniformidade de distribuição de água e na vazão de um tubogotejador com vazão de 2,2 L h-1, foram testados quatro níveis de concentrações de dicloroisocianurato de sódio (N1 = 0, N2 = 15, N3 = 30 e N4 =45 mg L-1 de cloro livre). As avaliações foram realizadas no início do experimento e a cada 100 horas de funcionamento do sistema, totalizando 8 avaliações. No cálculo da uniformidade de aplicação de água foram utilizados os coeficientes de uniformidade deChristiansen (CUC), de distribuição (CUD) e de emissão (Us). Também se realizou o estudo da vazão e do coeficiente de variação da vazão (CVq). Verificou-se que no nível N1 ocorreram reduções de 23; 30,2 e 8,35%, para o CUC, CUD e Us, respectivamente, sendo que a vazão apresentou uma redução de 6,13%, refletindo em um aumento do CVq. Otratamento com dicloro foi eficiente para precaver contra entupimento para todas as concentrações utilizadas e o sistema foi classificado com excelente uniformidade em praticamente todas as avaliações.<br><br>To evaluate the effect of the organic chlorination in the uniformity of water distribution and in the outflow of a tubedripper with 2,2 L h-1, had been tested four levels of concentrations of dicloroisocianurato of sodium (N1 = 0, N2 = 15, N3 = 30 e N4 = 45 mg L-1 of free chlorine). The evaluations had been carried through in the beginning of the experiment and to each 100 hours of functioning of the system, totalizing 8 evaluations. In the calculation ofthe uniformity of water application had been used the coefficients of uniformity of Christiansen (CUC), of distribution (CUD) and emission (Us). Also the study of the discharge and the coefficient of variation of the discharge (CVq). It was verified that in thelevel N1, reductions of 23; 30.2 and 8.35%, for the CUC, CUD and US, respectively. The discharge presented a 6.13% reduction, reflecting in an increase of the CVq. The treatment with dicloro was efficient to prevent against clogging for all the used concentrations and thesystem was classified with excellent uniformity in practically all the evaluations.
显示更多 [+] 显示较少 [-]