خيارات البحث
النتائج 1 - 3 من 3
This article has no title in english | Ureteroneocistostomia extravesical modificada pela sondagem ureterovesical peroperatória no autotransplante renal em cães
2007
Guilherme Lages Savassi-Rocha | Ney Luis Pippi | Rosana Keller Richter | Carmen Lice Buchmann Godoy | Ângela Patricia Medeiros Veiga | Ana Neri Christo de Oliveira | Sheila Francheska da Silva Camargo | Charles Pelizzari | André Luis Lima de Oliveira | Ademar Luis Dallabrida | Eduardo Santiago Ventura de Aguiar | Simone Bopp
To test a modified extravesical ureteroneocystostomy using a urethral probe like a stent just on the peroperative time, seven adult mongrel dogs underwent bilateral nephrectomy followed by unilateral autotransplantation. The other kidney was discarded. The evaluation of the animals was made by ultrasonography and clinical exams for the first six weeks after the surgery. The excretory urography was made on the end of this period. Then, the clinical exams were done by at least four months in each dog, without any complication. The technique of urinary tract reconstruction was considered efficient, without urological complications on the postoperative time of all the dogs. | Realizou-se, em sete cães adultos, o autotransplante renal esquerdo associado à nefrectomia contralateral para avaliação da técnica de ureteroneocistostomia extravesical modificada pela sondagem ureterovesical peroperatória. Durante a sutura do ureter na bexiga, foi mantida uma sonda uretral na região da anastomose ureterovesical, o que facilitou a realização da técnica cirúrgica e permitiu a confecção de anastomose de diâmetro adequado. A avaliação do rim transplantado e do ureter correspondente foi feita mediante ultra-sonografia a cada sete dias durante as seis primeiras semanas de pós-operatório, período em que também se fez o exame clínico diário de todos os animais. No último dia (42º) da avaliação a curto prazo, realizou-se a urografia excretora. Em seguida, manteve-se acompanhamento clínico periódico dos sete cães por um período mínimo de quatro meses, sem que fosse detectada qualquer alteração digna de nota. A técnica de reconstrução do trato urinário utilizada mostrou-se eficiente, não se observando nenhuma complicação urológica no pós-operatório de todos os animais.
اظهر المزيد [+] اقل [-]Computed tomography exam of the thorax of bitches with malignant mammary gland tumors: I - Technical exam determination | Tomografia computadorizada do tórax de cadelas portadoras de neoplasias mamárias malignas: I - determinação da técnica do exame
2006
Ana Carolina Brandão de Campos Fonseca Pinto | Masao Iwasaki | Cláudia Figueiredo | Sílvia Renata Gaido Cortopassi | Franklin de Almeida Sterman
Given the importance of malignant mammary gland tumors in veterinary medicine clinics, new perspectives of diagnostic imaging in order to evaluate pacients that have this neoplasia, and the lack of information about it in literature, this research intended to analyse some technical aspects of the contrast computed tomography scanning. The scanning time, the choice of the axial slices thickness, quality of the mediastinal vases contrast and the window width and level were studied in order to have images that make possible the evaluation of lungs, mediastinum, and bones. This research was performed at the Diagnostic Imaging Service of the Veterinary School Hospital of the Faculdade de Medicina Veterinária e Zootecnia at the University of São Paulo in twenty, different breed and age, bitches with malignant mammary gland tumors that were examined at the Obstetric and Ginecology and Small Animal Surgery Services of the same hospital. The average time for the complete contrast computed tomography scanning of the thorax, with nearly 30 slices, was thirty minutes; the ventral recumbency with the cranial traction of thoracic limbs, and the administration of intravenously iodine contrast medium (2ml/kg) that was given; two thirds of the dose in bolus and the complement under continuing infusion presented to be appropriate for the thoracic contrast computed tomography scanning. The 10 milimeters thickness for animals weighting over 30 kilograms and 5 milimeters for animals weighting under 30 kilograms presented to be appropriate in order to reach an average of thirty slices; the window and level selections to obtain pulmonary, mediastinal and bone images presented appropriate to be evaluated starting from window width 1500 Hounsfield unit (HU) with level varyng from -550 e -650 for lungs, window width between 250 to 300 HU with level varyng from 0 e 50 for mediastinum and window width of 1500 with the level between 50 and 350 HU. | Visto a importância das neoplasias mamárias malignas na clínica médico-veterinária e as novas perspectivas do diagnóstico por imagem na avaliação de pacientes portadores dessas neoplasias, o presente trabalho visou analisar alguns aspectos técnicos relativos ao exame de tomografia computadorizada contrastada da cavidade torácica quais sejam, tempo de realização do exame, escolha da espessura dos cortes transversais, qualidade de contrastação dos vasos mediastinais, abertura de janela e nível para obtenção das imagens de pulmão, mediastino e arcabouço ósseo, tendo em vista a escassez de informações na literatura consultada. Para tanto, foram realizados exames de tomografia computadorizada contrastada da cavidade torácica de vinte fêmeas da espécie canina, de diferentes raças e idades, portadoras de neoplasias mamárias malignas encaminhadas ao Serviço de Diagnóstico por Imagem do Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo pelos Serviços de Obstetrícia e Ginecologia e de Cirurgia de Pequenos Animais da mesma instituição. Concluiu-se que, o tempo médio para realização da tomografia contrastada completa do tórax, com aproximadamente trinta cortes foi de 30 minutos; o posicionamento em decúbito esternal com os membros tracionados cranialmente, e a administração de contraste iodado hidrossolúvel por via intravenosa no volume aproximado de 2ml/kg de peso vivo, sendo dois terços da dose administrados em bolo e o complemento sob infusão contínua mostraram-se adequados para realização do exame tomográfico contrastado do tórax; a escolha da espessura dos cortes de 10 milímetros para animais com mais de trinta quilos e de 5 milímetros para animais com menos de trinta quilos mostrou-se adequada para avaliação de todo o tórax buscando-se atingir uma média de trinta cortes; as seleções de janela e nível para aquisição das imagens pulmonares, mediastinais e de arcabouço ósseo apresentaram-se adequadas à avaliação a partir dos valores de abertura de janela de: 1500 unidades Hounsfield (UH) com um nível entre -550 e -650 UH para pulmão, entre 250 e 300 UH com um nível entre 0 e 50 UH para mediastino e para avaliação do arcabouço ósseo de 1500 UH com um nível entre 50 e 350 UH.
اظهر المزيد [+] اقل [-]Recovery of Toxocara canis larvae from mouse tissue | Recuperação de larvas de Toxocara canis de tecidos de camundongo
1997
Cáris Maroni Nunes | Saemi Ogassawara
Two techniques, peptic digestion and homogenization, were tested for the recovering of Toxocara canis larvae from mice tissue. Twenty mice were fed 1.000 embryonated eggs, and after 44-46 hours the animals were euthanised and liver and lungs were evaluated for the presence of larvae. Recovery rate from liver was greater than from lungs. Homogenization technique resulted in better percentage of larvae recovered, regardless of the organ evaluated. | Foram avaliadas duas técnicas de recuperação de larvas de Toxocara canis em hospedeiro paratênico: digestão enzimática e homogeneização. Vinte camundongos foram oralmente inoculados com 1.000 ovos de Toxocara canis\ após 44-46 horas procedeuse à recuperação das larvas do parasito no fígado e pulmões dos animais. O fígado apresentou maior número de larvas quando comparado aos pulmões. A técnica de homogeneização, quando comparada à técnica de digestão, revelou-se mais eficiente para a<br />recuperação de larvas, independentemente do órgão avaliado.
اظهر المزيد [+] اقل [-]