Refine search
Results 1-4 of 4
Comparison of flunixin meglumine and flurbiprofen for control of ocular irritative response in dogs
1991
Millichamp, N.J. | Dziezyc, J.
Dogs were treated with the cyclo-oxygenase inhibitors flunixin meglumine IV or flurbiprofen topically. Acute inflammation was induced in the eyes by disruption of the anterior lens capsule, using a neodymium:yttrium aluminum garnet laser. Pupil diameter and intraocular pressure were measured before and after inducing ocular inflammation. Both drugs maintained mydriasis and increased intraocular pressure in the inflamed eyes, compared with untreated controls.
Show more [+] Less [-]Uterine and fetal dynamics during early pregnancy in mares
1991
Griffin, P.G. | Ginther, O.J.
Fetal activity and mobility and changes in diameter of the allantoic fluid compartment in the uterine horns were studied in mares between days 69 and 81 of pregnancy by use of transrectal ultrasonography (n = 12) and transcervical videoendoscopy (n = 8). The insertion tube of the videoendoscope was positioned within the allantoic sac to permit viewing of the fetus and entrance to each uterine horn. Each uterine horn was divided ultrasonographically into 3 segments of equal length, and the horns were designated on the basis of side of umbilical attachment (cord vs noncord horns). The diameter of the allantoic fluid compartment in the cornual segments increased (P < 0.05) over the cranial (18.6 +/- 1.9 mm), middle (35.6 +/- 2.9 mm), and caudal (51.7 +/- 4.4 mm) segments, but differences between cord and noncord horns were not evident. Dynamic changes in diameter of the allantoic fluid compartment in cornual segments (ultrasonography) and at the entrance to each uterine horn (videoendoscopy) were detected (no significant difference between methods). During continuous videoendoscopic viewing (17 to 60 min/mare), extreme changes in allantoic fluid compartment diameter (76 to 100% of maximum to 0 to 25% of maximum or vice-versa) occurred an equivalent of 2.6 times/h/horn entrance; changes had an average duration of 3.4 minutes. A change from 100% (maximal diameter) to 0% (no visible lumen) or vice-versa occurred an equivalent of 1.3 times/h/horn entrance. Sometimes the uterine wall was so closely constricted around the fetal-amniotic unit that no intervening allantoic fluid was ultrasonographically detectable, whereas at other times, the uterus in the same location was widely dilated. Results indicated that extensive allantoic fluid shifts were associated with frequent diameter changes in various segments of the uterus. On the basis of 30-second activity trials every 10 minutes, the fetus was active 27% and was quiet 73% of the time (combined ultrasonographic and videoendoscopic data). Activity sometimes involved only movements of extremities, head, or mouth, whereas at other times, a sudden burst of intense whole-body activity was observed. The vigorous whole-body movements buoyed the fetus into the allantoic fluid, and movements of the extremities often caused the fetus to push away from the allantoic wall, resulting in marked changes in location, recumbency, and presentation (direction faced by fetus). Several instances were observed during videoendoscopic examination, in which the fetal-amniotic unit appeared to be forced through a constricted horn entrance into the allantoic fluid compartment at the dilated uterine body. On the basis of continuous videoendoscopic viewing, the fetus changed locations among the major portions of the uterus (body and each horn), on average, 5.0 times/h. Changes in recumbency and presentation occurred, on average, 10.5 and 5.0 times/h, respectively. The frequency of type of recumbency decreased (P < 0.005) as follows: lateral, 23 of 39 (59%); dorsal, 15 of 39 (38%); and ventral, 1 of 39 (3%). Frequency of cranial, caudal, and transverse presentation was not different between cord and noncord horn. Caudal presentation was more common (P < 0.005) when the fetus was in a uterine horn (47/70, 67%) than when it was in the uterine body (15/50, 30%; combined ultrasonographic and videoendoscopic data). Transverse presentation was more common (P < 0.005) when the fetus was in the uterine body (14/50, 28%) than when it was in a horn (4/70, 6%). Results indicated that the early stage equine fetus (days 69 to 81) is extremely mobile within the allantoic fluid, with frequent (several times per hour) changes in location, recumbency, and presentation.
Show more [+] Less [-]Acute effects of anti-inflammatory drugs on neodymium:yttrium aluminum garnet laser-induced uveitis in dogs
1991
Millichamp, N.J. | Dziezyc, J. | Rohde, B.H. | Chiou, G.C.Y. | Smith, W.B.
Dogs were treated with flunixin meglumine, a cyclo-oxygenase inhibitor; L-651,896, a 5-lipoxygenase inhibitor; and matrine, a herbal anti-inflammatory drug. Acute inflammation was induced in the eyes by disruption of the anterior lens capsule, using a neodymium:yttrium aluminum garnet laser. Intraocular pressure, pupil diameter, and eicosanoid production in the aqueous humor were measured. Statistically significant effects were seen in the eyes of flunixin meglumine-treated dogs where mydriasis was maintained and aqueous prostaglandin E2 concentration was reduced.
Show more [+] Less [-]Morphologic and morphometric study of the facial nerve in clinically normal adult dogs
1991
Braund, K.G. | Mehta, J.R. | Amling, K.A. | Toivio-Kinnucan, M.
A morphologic and morphometric study was carried out on the facial nerve: to determine normal histologic data in myelinated fibers of clinically normal young adult dogs; to establish reference values for mean fiber diameter, and to delineate the relative diameter frequency distribution curve. Few degenerative changes were observed in single teased-nerve fibers and semithin cross-sectional nerve preparations. Statistical difference was not observed between left and right facial nerves. The distribution of fiber diameters in the facial nerve was unimodal. Mean (+/- SD) fiber diameter of the facial nerve was 3.92 +/- 1.18 micromole. Approximately 89% of fibers in the facial nerve had diameter between 3 and 6 micromole. Fiber diameter ranged from 2 to 12 micromole; however, < 1% of fibers had diameter > 8 micromole.
Show more [+] Less [-]