Refine search
Results 41-50 of 1,126
Homeopatia e água: volume 1: resultados experimentais sobre tratamento da água com altas diluições Full text
2012
Casali, Vicente Wagner Dias | Andrade, Fernanda Maria Coutinho de
Homeopatia y agua: volumen 1: Resultados experimentales sobre tratamiento del agua con altas diluciones Full text
2012
Casali, Vicente Wagner Dias | Andrade, Fernanda Maria Coutinho de
Homeopatia e água: volume 5: resultados experimentais sobre tratamento da água com altas diluições Full text
2012
Casali, Vicente Wagner Dias | Andrade, Fernanda Maria Coutinho de
Gestão da água no Regadio Full text
2012
Shahidian, Shakib | Shahidian, Shakib | Guimarães, Rita | Rodrigues, Carlos
A gestão da rega tem como objetivo responder às seguintes duas perguntas: quando regar e quanto regar. Os sistemas de rega sob pressão, como a gota-a-gota e o pivô simplificam e automatizam a rega, pelo que muitos agricultores esquecem da importância da gestão cuidada da rega, preferindo regar a mais do que ter de ajustar a rega às necessidades reais das plantas. Assim, nos controladores convencionais de rega, muitas vezes as dotações não são ajustadas ao longo do ciclo de crescimento, o que resulta em excesso de água nas primeiras fases de crescimento, em que as plantas são pequenas e a evapotranspiração é ainda reduzida, como é o caso de maio e junho, e algum stress nas plantas quando elas realmente precisam de água como é o caso da floração em julho e agosto. Por outro lado existe uma grande variabilidade climática entre os anos, pelo que a utilização da “média” será muitas vezes desajustada da realidade efetiva da cultura. Em muitas situações, um outro objetivo da gestão da água de rega é contornar ou minimizar problemas de qualidade da água e do solo tais como a salinidade, erosão do solo ou lixiviação dos nutrientes ou dos pesticidas para as águas subterrâneas. A perda de nutrientes por lixiviação só existe em caso de fluxo de água para fora da zona radicular, o que apresenta maior probabilidade de ocorrer em solo de textura ligeira. Nestes solos, de elevada condutividade hidráulica saturada e baixa capacidade de retenção da água, a lixiviação dos nitratos pode ocorrer por duas razões: aplicação de dotações elevadas e existência de intervalos muito pequenos entre as regas. Em contraste, nos solos de textura pesada, com baixa condutividade hidráulica e elevada capacidade de retenção da água, as perdas resultantes da rega poderão ocorrer apenas devido a dotações extremamente elevadas. Dada a grande importância económica e ambiental da gestão correta da rega, existem hoje inúmeras soluções técnicas ao dispor dos agricultores. De uma forma geral, podem classificar-se estes métodos de gestão de rega em métodos baseados na evapotranspiração, no teor de água no solo e no estado hídrico das plantas.
Show more [+] Less [-]Reutilizacion del agua: la agricultura y la gestion del agua urbana en una sociedad del reciclado Full text
2012
Reuso de água cinza e aproveitamento da água de chuva como fontes alternativas em propriedades rurais Full text
2012
Pires, João Daniel Torres Simões | Philippi, Luiz Sergio | Universidade Federal de Santa Catarina
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pos-Graduação em Engenharia Ambiental. | O déficit da cobertura de saneamento básico no Brasil é significativamente mais acentuado nas zonas rurais, onde a infraestrutura de saneamento básico é insuficiente ou inexistente. Tendo em vista que as áreas rurais são estratégicas para a produção de alimentos e preservação de recursos naturais, indisponíveis no ambiente urbano, medidas de controle da poluição e economia de recursos naturais são temas de grande relevância e que desafiam nossa sociedade. O objetivo do presente trabalho foi avaliar o potencial da água de chuva e da água cinza proveniente da lavagem de roupas, como fontes alternativas de água em propriedades rurais de base familiar. A propriedade piloto selecionada para a pesquisa contém quatro habitantes e está localizada no município de Palhoça, Santa Catarina. Primeiramente foi realizado um diagnóstico para determinar a demanda de água para fins não potáveis e os arranjos tecnologias capazes de suprir tais demandas através do aproveitamento de fontes alternativas de água disponíveis na propriedade. As tecnologias selecionadas correspondem a duas divisões de águas. A primeira refere-se à linha de água de chuva (azul), a qual consiste em captar esta através do telhado e, após o descarte da primeira água, aproveitá-la diretamente na máquina e tanque de lavar roupas, ou em outros fins, como a irrigação. A segunda linha é a de água cinza, que consiste no tratamento dos efluentes da máquina e do tanque de lavar roupas através de tanque séptico seguido de um filtro de fluxo horizontal subsuperficial (constructed wetland) plantado com macrófitas (cyperus papyrus). Este filtro foi dimensionado pela equação de cinética de primeira ordem, com área superficial de 0,8 m2 por habitante. O sistema de descarte da primeira água da chuva apresentou concentrações de DQO, turbidez e sólidos suspensos cerca de 40 a 60% superiores aos observados no reservatório de armazenamento. Ainda assim todos os parâmetros avaliados apresentaram a média dentro dos limites da norma brasileira, exceto coliformes fecais (38 NMP/ 100 mL), considerando que não foi adotado nenhum processo de desinfecção. Também foi avaliada a eficiência em cada etapa do tratamento da água cinza, sendo destacada a remoção global nas concentrações de sólidos suspensos (94%), sólidos totais (49%), DQO (91%), ortofosfato (95%) e coliformes fecais (171 NMP/100ml). De acordo com a norma brasileira, a água cinza tratada é adequada para as aplicações tipo classes 3 e 4, neste caso na descarga de bacio sanitário, limpeza de pisos e sistema de irrigação pontual. Simultaneamente ao monitoramento qualitativo, foi realizado um programa de micromedição do consumo de água da propriedade. Foi verificado que a água proveniente do poço freático corresponde a 54% do volume médio diário consumido, enquanto que a água da chuva armazenada e a água cinza tratada correspondem a 37% e 9%, respectivamente. Neste caso foi constatado um consumo médio de 142,8 L/hab.dia, que corresponde ao consumo residencial de padrão médio. | The deficit in sanitation coverage in Brazil is significantly more pronounced in rural areas, where sanitation infrastructure is insufficient or nonexistent. Considering that rural areas are strategic to food production and preservation of natural resources, unavailable in the urban environment, actions to control pollution and saving natural resources are issues of great relevance and challenge our society. The objective of this study was to evaluate the potential of rainwater and greywater from the laundry, as alternative sources of water on family farms. The property selected for the pilot survey contains four inhabitants and is located in the municipality of Palhoça, state of Santa Catarina. First, a diagnosis was made to determine the demand for non-potable water and technologies arrangements able to supply these demands, through the use of alternative water sources available at the property. The selected technologies corresponding to two divisions of water. The first one refers to rainwater (blue) line, which captures the rainwater through the roof, and then discards the first water, taking it directly to the tank, washing machine, and uses it for other purposes, such as irrigation. The second line is for graywater, which consists of washing machines and tank effluents treatment through the septic tank followed by a sub-surface horizontal-flow filter planted with macrophytes (Cyperus papyrus). This was calculated by the first order kinetics equation, with a 0.8 m2 surface area per inhabitant. The first rainwater discharge tank presented concentrations of COD, suspended solids and turbidity about 40 of 60% higher than those observed in the storage tank. Even though, all parameters showed that the average was inside the limits of the Brazilian standard, except for fecal coliforms (38 MPN / 100 ml), considering that was not adopted any disinfection process. Also was evaluated each stage efficiency of the gray water treatment, emphasizing the overall removing concentration of suspended solids (94%), total solids (49%), COD (91%), orthophosphate (95%) and fecal coliforms (171 NMP/100ml). According to the Brazilian standards, the treated graywater is suitable for applications of classes 3 and 4, in this case discharge on toilets, cleaning floors and punctual irrigation system. Simultaneously with the qualitative monitoring, an available alternative water sources consumptiom and production micro-measured program was also being performed at the property. It was identified that groundwater (used in the kitchen and bathroom) corresponds to 54% of the daily average volume consumed, while the rainwater stored and treated graywater corresponded to 37% and 9%, respectively. In this case was observed a household consumption on average 142.8L/per day, which corresponds to an average pattern of residential consumption.
Show more [+] Less [-]Dining out: Bryconops caudomaculatus jumps out of water to catch flies Cenar afuera: Bryconops caudomaculatus salta del agua para atrapar moscas Full text
2012
RAUL COSTA-PEREIRA | FRANCISCO SEVERO-NETO
Condutividade elétrica em função do teor de água inicial de sementes de amendoim Electrical conductivity and water content in peanut seeds Full text
2012
Rafael Marani Barbosa | Clíssia Barboza da Silva | Maria Aparecida de Medeiros | Maria Aparecida Pessôa da Cruz Centurion | Roberval Daiton Vieira
O vigor de sementes de amendoim (Arachis hypogaea L.) avaliado pelo teste de condutividade elétrica demonstra estreita relação com o desempenho no campo, mas alguns fatores podem afetar o resultado da condutividade elétrica, sendo um destes o teor de água inicial das sementes. Assim, o objetivo deste trabalho foi avaliar o teor de água ou faixa de umidade da semente mais adequado para a avaliação da condutividade elétrica em sementes de amendoim. Quatro lotes de sementes da cultivar 'IAC Tatu ST' e quatro da cultivar 'IAC Runner 886' foram avaliados quanto ao seu potencial fisiológico e posteriormente o teor de água foi ajustado para 5, 7, 9, 11, 13 e 15%, pelo método da atmosfera úmida. O delineamento foi inteiramente casualizado em esquema fatorial 4×6 (lotes × teores de água) para as sementes de cada cultivar, em quatro repetições e os resultados para o fator teor de água foram submetidos à análise de regressão. A maior relação da condutividade elétrica com vigor das sementes ocorreu naquelas com teor de água entre 9 a 15%, de forma que sementes com 5 a 7% de umidade não devem ser submetidas ao teste de condutividade elétrica, porque os lotes expressam alto padrão de germinação e vigor. A condutividade elétrica de sementes de amendoim é influenciada pelo teor de água e a estabilização dos resultados ocorre quando elas estão com teor de água entre 10 e 14%.<br>The vigor of peanut seeds (Arachis hypogaea L.) assessed by the conductivity test shows close relationship with performance in the field, but some factors may affect the outcome of the electrical conductivity, being one of that the initial water content of seeds. The objective of this study was to evaluate the seed water content most appropriate for evaluating the seed vigor through electrical conductivity test in peanut. Four seed lots of 'IAC Tatu ST' cultivar and four 'IAC Runner 886' were initially evaluated for their physiological potential and subsequently the seed water content was adjusted to 5, 7, 9, 11, 13 and 15% by the method of controlled atmosphere. A completely randomized design with treatments arranged in a 4×6 factorial design (seed lots × seed water content levels) for each cultivar and four replications were used. The results for the factor seed water content were subjected to the analysis regression. The higher relationship of electrical conductivity and seed vigor occurred when the seed lots presents seed moisture content varying from 9 to 15%. Seeds with 5-7% moisture should not be subjected to electrical conductivity test, because lots express high standard germination and vigor. The electrical conductivity of peanut seeds is influenced by the seed moisture content and the stabilization of the results occurs when the seeds have moisture content between 10 and 14%.
Show more [+] Less [-]Anthropogenic carbon and water masses in the Bay of Biscay | Carbono antropogénico y masas de agua en el Golfo de Vizcaya Full text
2012
Castaño, Mónica | Pardo, Paula C. | Álvarez-Rodríguez, Marta | Rodríguez, C. | Carballo, R. | Ríos, Aida F. | Pérez, Fiz F.
Anthropogenic carbon and water masses in the Bay of Biscay | Carbono antropogénico y masas de agua en el Golfo de Vizcaya Full text
2012
Castaño, Mónica | Pardo, Paula C. | Álvarez-Rodríguez, Marta | Rodríguez, C. | Carballo, R. | Ríos, Aida F. | Pérez, Fiz F.
16 páginas, 4 figuras, 3 tablas | [EN] As part of the VACLAN (Climatic Variability in the North Atlantic) project a section covering the Bay of Biscay was sampled on board R/V Thalassa in September 2005. This work estimates the distribution of the different water masses using an extended optimum multiparametric method and it studies water mass distribution of anthropogenic carbon as calculated with two different approaches. Regarding water masses present in this region, the Eastern North Atlantic Central Water layer is mainly constituted by its subpolar component and the Mediterranean Water appears very diluted, increasing its dilution towards Northeast. In relation to the anthropogenic carbon inventory there are small differences between two different methods used, 95 vs 87 mol C m-2, both with the same distribution pattern where the concentration decreases with the depth. Eastern North Atlantic Central Water presents the highest anthropogenic carbon inventory, supporting more than 50% of the total column (52%). This work confirms the relevant role of the Bay of Biscay as a sink zone in the oceanic circulation. | [ES] En septiembre de 2005, a bordo del B/O Thalassa y como parte del proyecto VACLAN (Variabilidad CLimática en el Atlántico Norte) se muestreó una sección atravesando el Golfo de Vizcaya. Este trabajo estima la distribución de las diferentes masas de agua usando un método óptimo multiparamétrico extendido y estudia la distribución de carbono antropogénico en las mismas calculado usando dos métodos distintos. Con respecto a las masas de agua presentes en la región, la capa de Agua Central del Este del Atlántico Norte está principalmente constituida por su componente subpolar y el agua Mediterránea aparece muy diluida, aumentando su dilución hacia el Noreste. En relación al inventario de carbono antropogénico hay pequeñas diferencias entre los dos métodos utilizados, 95 vs 87 mol C m-2, aunque en ambos se observa el mismo patrón de distribución vertical, la concentración decrece con la profundidad. El Agua Central del Este del Atlántico Norte presenta el mayor inventario de carbono antropogénico, constituyendo más del 50% de la columna total (52%). Este trabajo confirma el papel relevante del Golfo de Vizcaya como una zona sumidero de carbono antropogénico en la circulación oceánica. | This work was developed and funded by the MCyT (REN2003-08193-C03, CTM2008-05189-E/MAR) and by the Xunta de Galicia (M4AO project PGIDIT07PXB402153PR). | Peer reviewed
Show more [+] Less [-]Anthropogenic carbon and water masses in the Bay of Biscay | Carbono antropogénico y masas de agua en el golfo de Vizcaya
Calidad del agua de unidades odontológicas Full text
2012
Sara Ávila de Navia | Sandra Mónica Estupiñán Torres | Diana Milena Estupiñán Torres
El agua es una fuente importante de contaminación en pacientes odontológicos, esta contaminación se ha clasificado en dos clases: la primera, proveniente del suministro primario de agua, es decir, del agua pública y, la segunda, la que se encuentra adherida a las paredes de las mangueras de la unidad odontológica formando una biocapa, que se forma por los fluidos orales que son aspirados durante el procedimiento. La biocapa estará continuamente contaminando las mangueras de la unidad y expulsando microorganismos a la cavidad oral del paciente donde se generan aerosoles que pueden contaminar el ambiente, las superficies, los instrumentos y al personal de salud, lo que representa un riesgo en salud pública. En Colombia, no existen reportes oficiales ni datos que permitan controlar este problema de salud pública, por lo que los riesgos de contaminación e infección bacteriana siguen siendo latentes en la actualidad.
Show more [+] Less [-]