New type of ozone generator based on barrier discharge was applied for removal of phenol from water under laboratory conditions. Three water samples with initial concentration of phenol of 6.0 mg/L were studied. In the experiment with distilled water containing phenol, 98.9% of phenol was removed (93.3% during the ozonization). Under similar conditions two different water samples from river Danube were used. In these cases, 76.7% and 80.0% of phenol were removed, respectively. In all experiments, water samples containing phenol passed only once through the ozonizer. It is reasonable to assume that better purification could be obtained with several passes of water through ozonizer and/or by optimization of the process (adjusting concentration of ozone, ozonization time, water flow, etc.).