Model investigationss [i.e. investigations] of ejector for dosage of ozone into water | Modelska ispitivanja ejektora za doziranje ozona pri mesanju sa vodom
2009
Batinic, B., Univerzitet u Beogradu, Beograd (Serbia). Gradjevinski fakultet | Prodanovic, D., Univerzitet u Beogradu, Beograd (Serbia). Gradjevinski fakultet | Randelovic, A., Univerzitet u Beogradu, Beograd (Serbia). Gradjevinski fakultet
A series of measurements has been conducted with various combinations of ejector dimensions. Variables were diameter of the nozzle and the distance between the end of the nozzle and the beginning of the pipe. Vacuum head in function of water flow was measured when there was no air flow, and when there was air flow (from a reservoir with constant volume). The results are presented in this paper.
Mostrar más [+] Menos [-]Palabras clave de AGROVOC
Información bibliográfica
Este registro bibliográfico ha sido proporcionado por Matica Srpska Library