In vitro development and evaluation of a polyacrylic acid–silicone device intended for gradual occlusion of portosystemic shunts in dogs and cats
2016
Wallace, Mandy L. | Ellison, Gary W. | Batich, Christopher | Case, Brad | Kim, Stanley E.
OBJECTIVE To develop a device intended for gradual venous occlusion over 4 to 6 weeks. SAMPLE Silicone tubing filled with various inorganic salt and polyacrylic acid (PAA) formulations and mounted within a polypropylene or polyether ether ketone (PEEK) outer ring. PROCEDURES 15 polypropylene prototype rings were initially filled with 1 of 5 formulations and placed in PBSS. In a second test, 10 polypropylene and 7 PEEK prototype rings were filled with 1 formulation and placed in PBSS. In a third test, 2 formulations were loaded into 6 PEEK rings each, placed in physiologic solution, and incubated. In all tests, ring luminal diameter, outer diameter, and luminal area were measured over 6 weeks. RESULTS In the first test, 2 formulations had the greatest changes in luminal area and diameter, and 1 of those had a greater linear swell rate than the other had. In the second test, 6 of 7 PEEK rings and 6 of 10 polypropylene rings closed to a luminal diamater < 1 mm within 6 weeks. Polypropylene rings had a greater increase in outer diameter than did PEEK rings between 4.5 and 6 weeks. In the third test, 11 of 12 PEEK rings gradually closed to a luminal diameter < 1 mm within 6 weeks. CONCLUSIONS AND CLINICAL RELEVANCE A PAA and inorganic salt formulation in a prototype silicone and polymer ring resulted in gradual occlusion over 4 to 6 weeks in vitro. Prototype PEEK rings provided more reliable closure than did polypropylene rings.
Mostrar más [+] Menos [-]Palabras clave de AGROVOC
Información bibliográfica
Este registro bibliográfico ha sido proporcionado por National Agricultural Library