Refinar búsqueda
Resultados 1-2 de 2
EFFECT OF CROP ROTATIONS AND NITROGEN FERTILIZATION ON YIELD, YIELD COMPONENTS AND ASSOCIATED WEEDS IN COTTON
2007
S Toaima
This study was conducted at Sids Experimental Research Station, Beni Suief Governorate, starting from year 2000 to study the effect of rotation dura-tion (every year, 2- year rotation and 3- year rota-tion) and nitrogen fertilizer rates; 45, 60 and 75 kg N/ fed on growth, yield components and yield of cotton, as well as associated weeds. A split plot design was used with four replicates. The data indicated that crop rotation had significant effect on plant height, number of fruiting branches/ plant, number of open bolls, seed cotton yield/ plant and seed cotton yield/ fed. Seed cotton yield/ fed was increased by 10.99 and 23.62 % when 2-year and 3-year rotations were applied, compared to 1-year rotation (average of both seasons). In-creasing N- fertilization up to 60 kg N/ fed caused significant increases in all studied traits. The best estimate of yield (Y) plotted against N rate (X) for annually rotated cotton was the linear equation of Y =2.44 + 0.074x (R2 =0.81). Two years rotation showed a quadratic association with increasing the N rate, R2 = 0.86 and 0.88, respectively. The high-est values of total fresh weeds were 2.85 and 2.60 kg/ m2 (broad and grassy weeds) when 1-year ro-tation was applied, while the lowest values were 1.50 and 1.35 kg/ m2 when 3-year rotation was applied in the first and second season, respective-ly.
Mostrar más [+] Menos [-]RAPID ESTIMATIONS OF BIOLOGICAL FINENESS OF COTTON FIBERS USING MICROMAT DATA
2007
A Mohamed | M Sief | S El-Hariry
Rapid estimations of diameter minus lumen(D-L), and outer perimeter of cotton fibers (P) inmicrons, as a biological fineness of Egyptian cottoncould be calculated with satisfactory levels ofaccuracy from hair weight (H.W) in m/tex andmaturity ratio )MR) obtained from Micromat data(new F/MT instrument), using the following equations:2Circularity x 3.14 x 1.52Hs (Standard finenessDiameter (microns) or Final format (D) (microns) = 1.205 HsorCircularit y × 1.524 x 3.14 x HsPerimeter (microns) or Final format (P) (microns) = 3.7853 HsResults of the current study suggested thatmore attention should be focused on meaning andmeasurements of the three values of biologicalfineness (i.e.) diameter (D), perimeter (P) (microns)and standard fineness (Hs) m/tex. whichcan be derived from the data obtained from Micromatinstrument.
Mostrar más [+] Menos [-]