Evaluation of an automated system for hemoglobin measurement in animals
1992
Callan, M.B. | Giger, U. | Oakley, D.A. | Scotti, M.V. | Shofer, F.S.
In veterinary medicine, PCV determined by centrifugation of blood in a microhematocrit tube is the most common clinical test used to initially assess and monitor anemic and polycythemic animals. In contrast, blood hemoglobin (Hb) concentration, rather than PCV, is generally determined in human patients. One automated system photometrically measures blood Hb concentration after conversion of Hb to azide methemoglobin without dilution and was found to be a simple and accurate instrument for use in human medicine. We evaluated the system for its accuracy in measuring blood Hb concentration in animals by comparing it with standard techniques and for its suitability in veterinary practice. Blood samples, anticoagulated with potassium EDTA, from 78 healthy animals (33 dogs, 17 cats, 13 horses, and 15 cows) and 58 dogs and 4 cats with various blood abnormalities (10 anemia, 11 polycythemia, 21 lipemia, 16 leukocytosis, and 6 icterus) were analyzed. In all species, blood Hb concentration of healthy animals determined by the system was comparable to that measured by standard cyanmethemoglobin methods (ie, an automated counter; rI = 0.987 to 0.998 and a hemoglobin kit, rI = 0.946 to 0.993). The aforementioned system also yielded similar values to those obtained by use of standard methods in anemic, polycythemic, and icteric dogs and cats. Moreover, the system reads the absorbance at 2 wavelengths to correct for turbidity, and therefore, accurately measured Hb concentration in blood samples with severe lipemia (triglycerides concentration > 500 mg/dl) and marked leukocytosis (> 50,000 WBC/microl), whereas other standard Hb techniques are known to give falsely high results. We conclude that the automated system compares favorably to standard methods, and is a simple and accurate instrument to quickly measure Hb concentration in animals.
Mostrar más [+] Menos [-]Bioelectrical impedance and zoometry for body composition analysis in domestic cats
1992
Stanton, C.A. | Hamar, D.W. | Johnson, D.E. | Fettman, M.J.
Zoometric measurements and bioelectrical impedance analysis were evaluated as methods of body composition determination in healthy cats. Zoometric and impedance measurements were taken on 22 anesthetized adult cats of various ages, genders, breeds, and body weights. The cats were then euthanatized. The bodies were processed through a tissue homogenizer and free-catch specimens were taken, freeze-dried, and analyzed for total body water, protein, fat, potassium, and ash content. Stepwise regression analysis was implemented to identify statistically significant relationships between the chemically determined dependent variables (total body water, protein, potassium, fat-free mass, fat mass, and percent body fat) and the zoometric measurements, with or without bioelectrical impedance analysis. Statistical analysis revealed high correlations between the dependent variables and the corresponding predicted values of those variables. Body weight alone was a poor predictor of body composition in these cats. On the basis of these findings, we suggest that zoometric and bioelectrical impedance measurements may serve as practical, noninvasive, simple, and accurate methods for estimating body composition in domestic cats.
Mostrar más [+] Menos [-]Accuracy of ultrasonography in the detection of severe hepatic lipidosis in cats
1992
Yeager, A.E. | Mohammed, H.
The accuracy of ultrasonography in detection of feline hepatic lipidosis was studied retrospectively. The following ultrasonographic criteria were associated positively with severe hepatic lipidosis: the liver hyperechoic, compared with falciform fat; the liver isoechoic or hyperechoic, compared with omental fat; poor visualization of intrahepatic vessel borders; and increased attenuation of sound by the liver. In a group of 36 cats with clinically apparent hepatobiliary disease and in which liver biopsy was done, liver hyperechoic, compared with falciform fat, was the best criterion for diagnosis of severe hepatic lipidosis with 91% sensitivity, 100% specificity, and 100% positive predictive value.