Refinar búsqueda
Resultados 1-10 de 35
Detection of myxoma virus in the classical form of myxomatosis using an AGID assay: statistical assessment of the assay’s diagnostic performance
2020
Kwit, Ewa | Osiński, Zbigniew | Lavazza, Antonio | Rzeżutka, Artur
The aim of the study was to estimate the diagnostic sensitivity (DSe) and specificity (DSp) of an agar gel immunodiffusion (AGID) assay for detection of myxoma virus (MYXV) in the classical form of myxomatosis and to compare its diagnostic performance to that of molecular methods (IAC-PCR, OIE PCR, and OIE real-time PCR). A panel of MYXV-positive samples of tissue homogenates with low (1 PCR unit – PCRU) and high (3,125 PCRU) virus levels and outbreak samples were used for method comparison studies. The validation parameters of the AGID assay were assessed using statistical methods. The AGID attained DSe of 0.65 (CI₉₅%: 0.53–0.76), DSp of 1.00 (CI₉₅%: 0.40–1.00), and accuracy of 0.67 (CI₉₅%: 0.55–0.76). The assay confirmed its diagnostic usefulness primarily for testing samples containing ≥3,125 PCRU of MYXV DNA. However, in the assaying of samples containing <3,125 PCRU of the virus there was a higher probability of getting false negative results, and only molecular methods showed a 100% sensitivity for samples with low (1 PCRU) virus concentration. The overall concordance of the results between AGID and IAC-PCR was fair (ĸ = 0.40). Full concordance of the results was observed for OIE PCR and OIE real-time PCR when control reference material was analysed. Findings from this study suggest that AGID can be used with some limitations as a screening tool for detection of MYXV infections.
Mostrar más [+] Menos [-]Comparison of a barium chloride test with ELISA for pregnancy detection in cows
2020
Dana, Omer Ismaeel | Ghaidan, Mnnat Talib | Mukhtar, Rafiq Hamakarim | Dyary, Hiewa Othman
Early detection of pregnancy is vital for appropriate reproductive management programmes to facilitate the rapid re-insemination of non-pregnant females and reduce the calving interval. A barium chloride test was compared with a commercial progesterone ELISA to detect pregnancy in non-descriptive cows and investigate if it could be applied as an alternative to ELISA in the field. Blood and urine samples were collected from 74 cows with recorded insemination dates. The progesterone ELISA and barium chloride assay were implemented to detect progesterone (P4) in blood and urine specimens, respectively. The cows' reproductive systems were examined after they were slaughtered to determine the uterus's status. Macroscopic examination of the uterus was used as a reference standard for both tests. The sensitivity rates of the P4 ELISA and barium chloride test to detect pregnant cows were 100.0% and 79.4%, and to detect the corpus luteum (CL) were 83.0% and 87.0%, respectively, their sensitivity increasing in the presence of the CL. The ELISA and barium chloride tests were 79.7% and 52.7% accurate in the diagnosis of pregnancy. The accuracy of the barium chloride test in CL detection increased to 81.0%, and that of the ELISA to 86.4%. There were no significant differences (P = 0.052) between the barium chloride assay and ELISA when they were utilised for the identification of the CL. The barium chloride test can be an inexpensive and time-saving alternative to ELISA in pregnancy diagnosis when the insemination date is known.
Mostrar más [+] Menos [-]Comparison of methods for estimation of Toxoplasma gondii-specific antibody production in the aqueous humor of cats
1995
Hill, S.L. | Lappin, M.R. | Carman, J.
Intraocular production of Toxoplasma gondii-specific antibody in cats has been estimated by comparing the ratio of T gondii-specific antibody in aqueous humor and serum with the ratio of total immunoglobulins in serum and aqueous humor (Goldmann-Witmer coefficient; aqueous antibody coefficient; C value). It has been proposed that in human beings, comparison of the ratio of T gondii-specific antibody in aqueous humor and serum with the ratio of antibodies against a nonocular pathogen in serum and aqueous humor is more accurate than methods using total immunoglobulin quantification. We developed an ELISA for detection of calicivirus-specific antibodies in the serum and aqueous humor of cats. By evaluating calicivirus-specific antibody concentrations in the aqueous humor of healthy and diseased cats, calicivirus was assessed as a nonintraocular pathogen. The ratio of T gondii-specific antibodies in the aqueous humor and serum and the ratio of calicivirus-specific antibodies in serum and aqueous humor were evaluated as a means of estimating intraocular T gondii-specific antibody production. A field strain of feline calicivirus was isolated, cultured, and purified. A calicivirus-specific IgG ELISA was developed for detection of feline calicivirus-specific IgG in serum and aqueous humor. Calicivirus-specific IgG was measured in the serum and aqueous humor from 3 groups of control cats. Results suggested that calicivirus is a nonintraocular pathogen in cats and that calicivirus IgG detected in aqueous humor is attributable to leakage across a damaged blood-ocular barrier. Intraocular production of T gondii-specific antibodies was estimated, using 2 formulas. The C value was calculated by multiplying the ratio of T gondii-specific IgM or IgG in aqueous humor and serum by the ratio of total immunoglobulins (using the corresponding IgM or IgG class) in serum and aqueous humor. The Ctc value (Toxoplasma-calicivirus Goldmann-Witmer coefficient) was calculated by multiplying the ratio of T gondii-specific IgM or IgG in aqueous humor and serum by the ratio of calicivirus-specific IgG in serum and aqueous humor. Serum and aqueous humor samples were obtained from 41 client-owned cats with uveitis, and T gondii-specific C values and Ctc values were calculated. Toxoplasma gondii-specific IgM or IgG C values of 10 or greater or T gondii-specific IgM or IgG Ctc values of 1 or greater were considered to be suggestive of intraocular T gondii-specific antibody production. Of the 41 cats, 20 (48.7%) had evidence of intraocular production of T gondii-specific antibody on the basis of either an IgM or IgG C value of 10 or greater. A Ctc value could not be calculated in 3 cats because calicivirus-specific IgG was not present in aqueous humor. Of the 38 cats for which Ctc values could be calculated, 25 (65.8%) had evidence of intraocular production of T gondii-specific antibody on the basis of either an IgM or IgG Ctc value of 1 or greater. The C values and Ctc values were in agreement for 75.9% of IgM containing samples and 75% of IgG containing samples. Sensitivity, specificity, predictive value of a positive test result, and predictive value of a negative test result for an IgM or IgG C value, when compared with the corresponding IgM or IgG Ctc value were determined. The results indicate that use of the C value for estimation of intraocular T gondii-specific antibody production will result in 28.6 (IgM) to 50% IgG) false-negative results and 12.5% (IgM and IgG) false-positive results, when compared with the Ctc value.
Mostrar más [+] Menos [-]Assessment of vertebral canal diameter and bony malformations of the cervical part of the spine in horses with cervical stenotic myelopathy
1994
Moore, B.R. | Reed, S.M. | Biller, D.S. | Kohn, C.W. | Weisbrode, S.E.
Magnification of cervical radiographs prevents accurate interpretation of vertebral canal absolute minimum sagittal diameter (MSD) values and application of the established MSD values for diagnosis of cervical stenotic myelopathy (CSM). Variability in MSD determination in human beings, owing to radiographic magnification, is minimized by assessing a ratio of the vertebral canal diameter to the sagittal width of the vertebral body. This relative measurement technique improves the accuracy of diagnosis of cervical spinal stenosis in human beings. The MSD of the vertebral canal was determined in 50 horses with CSM and 50 control horses, using a radiopaque marker method for correction of magnification. In addition, a ratio of the absolute MSD to the sagittal width of the vertebral body and a ratio of the absolute MSD to the length of the vertebral body were determined in 100 CSM-affected and 100 control horses. Response operating characteristic curve analysis of each method determined that the sagittal ratio method of canal diameter assessment provided the most accurate interpretation of cervical radiographs for diagnosis of CSM, with sensitivity and specificity of larger than or equal to 89% at each vertebral site. The accuracy of the ratio method, without consideration of bony malformation, supports the importance, and perhaps prerequisite, of generalized vertebral canal stenosis in the pathogenesis of CSM. Subjective evaluation of bony malformations from cervical radiographs of 100 CSM-affected horses and 100 control horses indicated that CSM-affected horses have more severe bony malformation than do control horses. However, moderate to marked degenerative joint disease of the articular processes was frequently observed in control horses. Subjective evaluation of bony malformation does not distinguish between CSM-affected and unaffected horses.
Mostrar más [+] Menos [-]Comparison of measured and calculated values for colloid osmotic pressure in hospitalized animals
1994
Brown, S.A. | Dusza, K. | Boehmer, J.
A relation exists between colloid osmotic pressure and serum total protein concentration; equations describing this relation have been used to determine a calculated value for colloid osmotic pressure. However, the relation between total protein concentration and colloid osmotic pressure is altered by the method used to measure protein and by changes in the ratio of concentrations of albumin (A) to globulin (G). We developed nomograms for estimating colloid osmotic pressure from A and G concentrations, using samples obtained from clinically normal animals and compared the accuracy of these nomograms with that of previously described equations relating colloid osmotic pressure to total protein concentration. For comparison, serum samples from canine (n = 106), equine (n = 79), feline (n = 24), and bovine (n = 27) patients admitted to the University of Georgia Veterinary Medical Teaching Hospital were used. Results indicated that nomograms based on protein concentration estimated by a refractometer generally were the least reliable. Although predictive nomograms, using total protein concentration determined by the biuret method, provided better results for serum samples, there was considerable variation between measured and calculated values for colloid osmotic pressure in all species studied. Calculated values for colloid osmotic pressure derived from A and G concentrations were most closely related to measured values for colloid osmotic pressure in dogs, horses, and cats. However, calculated values for colloid osmotic pressure differed from measured values by as much as 5 mm of Hg for some samples by each of the methods of estimation. These results indicate that, although calculated values for colloid osmotic pressure may be most accurate when variations in the A-to-G ratio are accounted for in the nomogram, none of the calculation methods provided a consistently accurate estimate of colloid osmotic pressure. For clinical patients, colloid osmotic pressure based on these nomograms cannot replace direct measurement.
Mostrar más [+] Menos [-]Reliability of single urine and serum samples for estimation of 24-hour urinary uric acid excretion in six healthy Beagles
1994
Bartges, J.W. | Osborne, C.A. | Felice, L.J. | Unger, L.K. | Bird, K.A. | Koehler, L.A. | Chen, M.
Urine uric acid-to-urine creatinine ratios (UUA:UC), urine uric acid concentrations, urine uric acid concentrations corrected for glomerular filtration rate, and urinary uric acid fractional excretions were compared with 24-hour urinary uric acid excretions measured in 6 healthy adult female Beagles. Comparisons, using correlation analysis, were made when dogs consumed a 10.4% protein (dry weight), casein-based diet and a 31.4% protein (dry weight), meat-based diet. The UUA:UC, urine uric acid concentrations corrected for glomerular filtration rate, and urinary uric acid fractional excretions were not reliable estimates of 24-hour urinary uric acid excretions during consumption of either diet. Urine uric acid concentrations in samples collected 2, 4, 6, and 24 hours after initiation of collection correlated with 24-hour urinary uric acid excretions when dogs consumed the casein-based diet; correlation was not found at any time interval when dogs consumed the meat-based diet. Therefore, determination of 24-hour urinary uric acid excretion is recommended because UUA:UC are unreliable.
Mostrar más [+] Menos [-]Evaluation of an automated system for hemoglobin measurement in animals
1992
Callan, M.B. | Giger, U. | Oakley, D.A. | Scotti, M.V. | Shofer, F.S.
In veterinary medicine, PCV determined by centrifugation of blood in a microhematocrit tube is the most common clinical test used to initially assess and monitor anemic and polycythemic animals. In contrast, blood hemoglobin (Hb) concentration, rather than PCV, is generally determined in human patients. One automated system photometrically measures blood Hb concentration after conversion of Hb to azide methemoglobin without dilution and was found to be a simple and accurate instrument for use in human medicine. We evaluated the system for its accuracy in measuring blood Hb concentration in animals by comparing it with standard techniques and for its suitability in veterinary practice. Blood samples, anticoagulated with potassium EDTA, from 78 healthy animals (33 dogs, 17 cats, 13 horses, and 15 cows) and 58 dogs and 4 cats with various blood abnormalities (10 anemia, 11 polycythemia, 21 lipemia, 16 leukocytosis, and 6 icterus) were analyzed. In all species, blood Hb concentration of healthy animals determined by the system was comparable to that measured by standard cyanmethemoglobin methods (ie, an automated counter; rI = 0.987 to 0.998 and a hemoglobin kit, rI = 0.946 to 0.993). The aforementioned system also yielded similar values to those obtained by use of standard methods in anemic, polycythemic, and icteric dogs and cats. Moreover, the system reads the absorbance at 2 wavelengths to correct for turbidity, and therefore, accurately measured Hb concentration in blood samples with severe lipemia (triglycerides concentration > 500 mg/dl) and marked leukocytosis (> 50,000 WBC/microl), whereas other standard Hb techniques are known to give falsely high results. We conclude that the automated system compares favorably to standard methods, and is a simple and accurate instrument to quickly measure Hb concentration in animals.
Mostrar más [+] Menos [-]Immunoturbidimetric quantification of serum immunoglobulin G concentration in foals
1990
Bauer, J.E. | Brooks, T.P.
Immunoturbidimetric determination of serum IgG concentration in foals was compared with the reference methods of single radial immunodiffusion and serum protein electrophoresis. High positive correlations were discovered when the technique was compared with either of these reference methods. The zinc sulfate turbidity test for serum IgG estimation was also evaluated. Although a positive correlation was discovered when the latter method was compared with reference methods, it was not as strong as the correlation between reference methods and the immunoturbidimetric method. The immunoturbidimetric method used in this study is specific and precise for equine serum IgG determination. It is rapid and, thus, is advantageous when timely evaluation of critically ill foals is necessary. The technique should be adaptable to various spectrophotometers and microcomputers for widespread application in veterinary medicine.
Mostrar más [+] Menos [-]Evaluation of isoflurane and sevoflurane vaporizers over a wide range of oxygen flow rates
2006
Ambrisko, T.D. | Klide, A.M.
Objective-To examine the accuracy and precision of isoflurane and sevoflurane anesthetic vaporizers. Sample Population-5 identcal isoflurane and 5 identical sevoflurane vaporizers. Procedures-Oxygen flow rates from 0.02 to 10 L/min were used with different vaporizer dial settings. Agent concentrations were measured at the common gas outlet by use of a refractometer. Accuracy was defined as the difference between measured agent concentrations, and dial settings were expressed as a percentage of the applied dial settings. Precision was defined as SD of the measured agent concentrations for each combination of dial setting and flow. Results-Isoflurane values were generally greater than the dial settings. Accuracy of the isoflurane vaporizer was > 20% when 0.6% and 1% was dialed. Accuracy of the sevoflurane vaporizer was always within +/- 20% but decreased at 0.02 L/min flow and at combinations of high flow and high dial settings. Overall precision of the isoflurane vaporizer was better than that of the sevoflurane vaporizer. Conclusions and Clinical Relevance-A possible explanation for the inaccuracy of the isoflurane vaporizer may be that it was manufactured to be accurate with air but not oxygen, which must be accounted for when using the vaporizer with oxygen, especially with nonrebreathing systems. The sevoflurane vaporizer may not deliver accurate agent concentrations at high flow and high dial settings. Both vaporizers are suitable for clinical use with a wide range of oxygen flow rates if these precautions are properly addressed.
Mostrar más [+] Menos [-]Oral administration of sucrose solutions and measurement of serum sucrose concentrations to evaluate gastric permeability in adult bottlenose dolphins (Tursiops truncatus)
2006
Buddington, K.K. | Holmes, W.E. | Clemons-Chevis, C.L. | Solangi, M.A. | Vanderpool, D. | Buddington, R.K.
Objective-To measure concentrations of sucrose in the serum of captive dolphins after oral administration of a sucrose solution and determine the suitability of this method for use as a test to detect gastric ulcers. Animals-8 adult captive bottlenose dolphins (Tursiops truncatus). Procedures-Blood samples were collected from the ventral fluke vein of dolphins before and 45 minutes after oral administration of 500 mL of solution containing 25 or 50 g of sucrose; oral administration was achieved by use of gastric intubation. Serum was separated, diluted in a solution of 90% acetonitrile-to-10% water that contained 10 ng of an internal standard (trichlormethiazide)/microliter, mixed, and centrifuged. Supernatant was analyzed by use of liquid chromatography-mass spectrometry-mass spectrometry (LC-MS-MS). Results-Serum sucrose concentrations of dolphins were at or less than the limits of detection before oral administration. Values after administration of sucrose solution varied among dolphins and were higher and more variable after administration of 50 g, compared with concentrations after administration of 25 g. Conclusions and Clinical Relevance-Serum sucrose concentrations in samples collected during routine health evaluations of captive dolphins can be reliably measured by use of LC-MS-MS. Correlating serum sucrose concentrations with endoscopic observations of the gastric mucosa of dolphins will validate this approach for use in screening for the prevalence and severity of gastric ulcers and determining the efficacy of treatment regimens.
Mostrar más [+] Menos [-]