Resultados 1-10 de 35
Detection of myxoma virus in the classical form of myxomatosis using an AGID assay: statistical assessment of the assay’s diagnostic performance Texto completo
2020
Kwit, Ewa | Osiński, Zbigniew | Lavazza, Antonio | Rzeżutka, Artur
Detection of myxoma virus in the classical form of myxomatosis using an AGID assay: statistical assessment of the assay’s diagnostic performance Texto completo
2020
Kwit, Ewa | Osiński, Zbigniew | Lavazza, Antonio | Rzeżutka, Artur
The aim of the study was to estimate the diagnostic sensitivity (DSe) and specificity (DSp) of an agar gel immunodiffusion (AGID) assay for detection of myxoma virus (MYXV) in the classical form of myxomatosis and to compare its diagnostic performance to that of molecular methods (IAC-PCR, OIE PCR, and OIE real-time PCR). A panel of MYXV-positive samples of tissue homogenates with low (1 PCR unit – PCRU) and high (3,125 PCRU) virus levels and outbreak samples were used for method comparison studies. The validation parameters of the AGID assay were assessed using statistical methods. The AGID attained DSe of 0.65 (CI₉₅%: 0.53–0.76), DSp of 1.00 (CI₉₅%: 0.40–1.00), and accuracy of 0.67 (CI₉₅%: 0.55–0.76). The assay confirmed its diagnostic usefulness primarily for testing samples containing ≥3,125 PCRU of MYXV DNA. However, in the assaying of samples containing <3,125 PCRU of the virus there was a higher probability of getting false negative results, and only molecular methods showed a 100% sensitivity for samples with low (1 PCRU) virus concentration. The overall concordance of the results between AGID and IAC-PCR was fair (ĸ = 0.40). Full concordance of the results was observed for OIE PCR and OIE real-time PCR when control reference material was analysed. Findings from this study suggest that AGID can be used with some limitations as a screening tool for detection of MYXV infections.
Mostrar más [+] Menos [-]Detection of myxoma virus in the classical form of myxomatosis using an AGID assay: statistical assessment of the assay’s diagnostic performance Texto completo
2020
Kwit Ewa | Osiński Zbigniew | Lavazza Antonio | Rzeżutka Artur
The aim of the study was to estimate the diagnostic sensitivity (DSe) and specificity (DSp) of an agar gel immunodiffusion (AGID) assay for detection of myxoma virus (MYXV) in the classical form of myxomatosis and to compare its diagnostic performance to that of molecular methods (IAC-PCR, OIE PCR, and OIE real-time PCR).
Mostrar más [+] Menos [-]Comparison of a barium chloride test with ELISA for pregnancy detection in cows Texto completo
2020
Dana, Omer Ismaeel | Ghaidan, Mnnat Talib | Mukhtar, Rafiq Hamakarim | Dyary, Hiewa Othman
Comparison of a barium chloride test with ELISA for pregnancy detection in cows Texto completo
2020
Dana, Omer Ismaeel | Ghaidan, Mnnat Talib | Mukhtar, Rafiq Hamakarim | Dyary, Hiewa Othman
Early detection of pregnancy is vital for appropriate reproductive management programmes to facilitate the rapid re-insemination of non-pregnant females and reduce the calving interval. A barium chloride test was compared with a commercial progesterone ELISA to detect pregnancy in non-descriptive cows and investigate if it could be applied as an alternative to ELISA in the field. Blood and urine samples were collected from 74 cows with recorded insemination dates. The progesterone ELISA and barium chloride assay were implemented to detect progesterone (P4) in blood and urine specimens, respectively. The cows' reproductive systems were examined after they were slaughtered to determine the uterus's status. Macroscopic examination of the uterus was used as a reference standard for both tests. The sensitivity rates of the P4 ELISA and barium chloride test to detect pregnant cows were 100.0% and 79.4%, and to detect the corpus luteum (CL) were 83.0% and 87.0%, respectively, their sensitivity increasing in the presence of the CL. The ELISA and barium chloride tests were 79.7% and 52.7% accurate in the diagnosis of pregnancy. The accuracy of the barium chloride test in CL detection increased to 81.0%, and that of the ELISA to 86.4%. There were no significant differences (P = 0.052) between the barium chloride assay and ELISA when they were utilised for the identification of the CL. The barium chloride test can be an inexpensive and time-saving alternative to ELISA in pregnancy diagnosis when the insemination date is known.
Mostrar más [+] Menos [-]Comparison of a barium chloride test with ELISA for pregnancy detection in cows Texto completo
2020
Dana Omer Ismaeel | Ghaidan Mnnat Talib | Mukhtar Rafiq Hamakarim | Dyary Hiewa Othman
Early detection of pregnancy is vital for appropriate reproductive management programmes to facilitate the rapid re-insemination of non-pregnant females and reduce the calving interval.
Mostrar más [+] Menos [-]Evaluation of assay procedures for prediction of passive transfer status in lambs Texto completo
2006
Massimini, G. | Peli, A. | Boari, A. | Britti, D.
Objective-To compare 4 assay procedures for prediction of passive transfer status in lambs. Animals-Thirty-one 1-day-old Sardinian lambs. Procedure-Serum IgG concentration was determined by use of single radial immunodiffusion. The following were determined: serum total protein concentration as measured by refractometry (ie, refractometry serum total protein concentration), serum total protein concentration as determined by the biuret method (ie, biuret method serum total protein concentration), serum gamma-globulin concentration as determined by serum protein electrophoresis, and serum gamma-glutamyltransferase (GGT) activity as measured by spectrophotometry. Accuracy of these assays for estimation of serum IgG concentration in 1-day-old lambs was established by use of linear regression analysis. Results-Refractometry serum total protein concentration, biuret method serum total protein concentration, and serum gamma-globulin concentration were closely and linearly correlated with serum IgG concentration. The natural logarithm (ln) of serum GGT activity was closely and linearly correlated with serum IgG concentration (ln). Refractometry serum total protein concentration, biuret method serum total protein concentration, and gamma-globulin concentration accounted for approximately 85%, 91%, and 95% of the variation in serum IgG concentration, respectively. Serum GGT activity (ln) accounted for approximately 92% of the variation in serum IgG concentration (ln). Conclusions and Clinical Relevance-For prediction of passive transfer status in 1-day-old lambs, serum GGT activity or biuret method serum total protein concentration determination will allow for passive transfer monitoring program development. Immediate refractometry serum total protein concentration determination is beneficial in making timely management and treatment decisions. Serum gamma-globulin concentration determination can be used as a confirmatory test.
Mostrar más [+] Menos [-]Evaluation of isoflurane and sevoflurane vaporizers over a wide range of oxygen flow rates Texto completo
2006
Ambrisko, T.D. | Klide, A.M.
Objective-To examine the accuracy and precision of isoflurane and sevoflurane anesthetic vaporizers. Sample Population-5 identcal isoflurane and 5 identical sevoflurane vaporizers. Procedures-Oxygen flow rates from 0.02 to 10 L/min were used with different vaporizer dial settings. Agent concentrations were measured at the common gas outlet by use of a refractometer. Accuracy was defined as the difference between measured agent concentrations, and dial settings were expressed as a percentage of the applied dial settings. Precision was defined as SD of the measured agent concentrations for each combination of dial setting and flow. Results-Isoflurane values were generally greater than the dial settings. Accuracy of the isoflurane vaporizer was > 20% when 0.6% and 1% was dialed. Accuracy of the sevoflurane vaporizer was always within +/- 20% but decreased at 0.02 L/min flow and at combinations of high flow and high dial settings. Overall precision of the isoflurane vaporizer was better than that of the sevoflurane vaporizer. Conclusions and Clinical Relevance-A possible explanation for the inaccuracy of the isoflurane vaporizer may be that it was manufactured to be accurate with air but not oxygen, which must be accounted for when using the vaporizer with oxygen, especially with nonrebreathing systems. The sevoflurane vaporizer may not deliver accurate agent concentrations at high flow and high dial settings. Both vaporizers are suitable for clinical use with a wide range of oxygen flow rates if these precautions are properly addressed.
Mostrar más [+] Menos [-]Effect of intensity of fecal pat sampling on estimates of Escherichia coli O157 prevalence Texto completo
2005
Echeverry, A. | Loneragan, G.H. | Wagner, B.A. | Brashears, M.M.
To evaluate site-to-site variation within fecal pats from cattle with regard to detection of Escherichia coli O157 and determine the effect on the accuracy of prevalence estimates of assay of multiple samples collected from the same fecal pat. 120 freshly voided fecal pats collected from 2 beef feedlots. Procedures-5 samples were systematically collected from each fecal pat and analyzed for E coli O157 via selective preenrichment techniques, immunomagnetic separation, and biochemical tests. Presumptive isolates were definitively identified via agglutination assays and polymerase chain reaction techniques. Best estimators of prevalence were calculated from the distribution of E coli O157-positive samples per pat. Of the 120 fecal pats, 96, 13, 4, 2, 3, and 2 fecal pats had 0, 1, 2, 3, 4, and 5 E coli O157-positive samples, respectively. The greatest estimate of E coli O157 prevalence (20%) was achieved when all 5 samples were assessed; this estimate represented a 2.4- fold increase in prevalence, compared with that provided via analysis of 1 sample/pat (8.2%). Compared with assessment of 5 sites/pat, the relative sensitivity of detecting an E coli O157-positive fecal pat via analysis of 1 site/pat was 40.1%. Results suggest that estimates of E coli O157 prevalence derived from sampling of 1 location/pat are likely underestimates of the true prevalence of this pathogen in fecal pats (and by extension, cattle). Additional research is warranted to confirm these results in situations of high and low prevalence and across different feedlots.
Mostrar más [+] Menos [-]Magnetic resonance arthrography of the scapulohumeral joint in dogs, using gadopentetate dimeglumine
1995
Bree, H van | Ryssen, B. van | Degryse, H. | Ramon, F.
Six scapulohumeral joints (3 normal joints and 3 joints with radiographic evidence of osteochondrosis) underwent conventional magnetic resonance (MR) imaging and MR scapulohumeral arthrography to evaluate delineation of the articular cartilage. The MR arthrography was performed, using 5 ml of 500 micromolar gadopentetate dimeglumine (Gd-DTPA) as a contrast medium. Delineation of normal articular cartilage and cartilage defects was less accurate after intra-articular administration of Gd-DTPA. Therefore, it was concluded that MR arthrography with Gd-DTPA is unrewarding for evaluation of osteochondrosis lesions.
Mostrar más [+] Menos [-]Sensitivity and specificity of various serologic tests for detection of Toxoplasma gondii infection in naturally infected sows
1995
Dubey, J.P. | Thulliez, P. | Weigel, R.M. | Andrews, C.D. | Lind, P. | Powell, E.C.
The sensitivity and specificity of various serologic tests for antibodies to Toxoplasma gondii were compared in 1,000 naturally exposed sows, using isolation of viable T gondii as the definitive test. Serum samples obtained from heart blood of 1,000 sows from Iowa were examined for T gondii antibodies by use of the modified agglutination test (MAT), latex agglutination test (LAT), indirect hemagglutination test (IHAT), and ELISA. Toxoplasma gondii was isolated from 170 hearts of 1,000 sows by bioassays in mice and cats. The percentage of samples diagnosed as positive for each of the serologic tests was: MAT = 22.2% (titer >greater than or equal to 1:20), IHAT = 6.4% (titer greater than or equal to 1:64), LAT = 10.4% (titer greater than or equal to 1: 64), and ELISA = 24.1% (OD > 0.360). The sensitivity and specificity of these tests were calculated respectively to be: 82.9 and 90.29% for MAT, 29.4 and 98.3% for IHAT, 45.9 and 96.9% for LAT, and 72.9 and 85.9% for ELISA. The dye test was run at 1:20 dilution on only 893 sera because of bacterial contamination and presence of anticomplement substances. Dye test antibodies were found in 17.8% of the sera, and sensitivity and specificity were 54.4 and 90.8%, respectively. Thus, the MAT had the highest sensitivity among all serologic tests used.
Mostrar más [+] Menos [-]Ultrasonography as a method to determine tendon cross-sectional area
1995
Gillis, C. | Sharkey, N. | Stover, S.M. | Pool, R.R. | Meagher, D.M. | Willits, N.
Ultrasonographic cross-sectional area (CSA) measurements of equine superficial digital flexor (SDF) tendon were obtained to determine the feasibility of ultrasonography for CSA measurement of tendon in vivo and in vitro. Ultrasonographic measurements were compared with a more traditional CSA measurement method, ink-blot analysis. In addition, values for ultrasonographic SDF tendon mean echogenicity were obtained in vivo and in vitro. The left forelimb SDF tendons of 23 horses were evaluated ultrasonographically. Cross-sectional images were acquired at 4-cm intervals distal to the base of the accessory carpal bone (DACB) to the level of the proximal sesamoid bones while horses were standing squarely. After euthanasia, the left forelimbs were mounted in a materials testing system (MTS) and loaded under tension to standing load. Ultrasonographic images were again acquired at the same locations. The ultrasonographic images were digitized, and values for ultrasonographic CSA and mean echogenicity were obtained for each level. Immediately after mechanical testing, a 1-cm-thick transverse section of SDF tendon at 12 cm DACB was removed. Three ink blots were prepared from each end of the removed tendon section and digitized. The 6 CSA values were averaged to generate a value for morphologic CSA for each SDF tendon at 12 cm DACB. Standing ultrasonographic tendon CSA at 12 cm DACB was consistently smallest (mean +/- SD CSA = 86 +/- 11 mm2), followed by MTS ultrasonographic CSA (mean, 95 +/- 12 mm2), with ink-blot morphologic CSA being largest (mean, 99 +/- 15 mm2). Comparison of standing and MTS ultrasonographic values at 12 cm DACB revealed a strong positive linear correlation between methods (R2 = 0.74, P = 0.001). Comparison of ink-blot CSA at 12 cm DACB with standing and MTS ultrasonographic CSA revealed strong positive linear correlations (R2 = 0.64, P = 0.001 and R2 = 0.72, P = 0.001, respectively). For ultrasonographic mean echogenicity, standing values insignificantly exceeded MTS values at each level. The authors conclude that ultrasonography is a useful technique for the noninvasive assessment of SDF tendon CSA that can be applied in vivo and in vitro.
Mostrar más [+] Menos [-]Reliability of single urine and serum samples for estimation of 24-hour urinary uric acid excretion in six healthy Beagles
1994
Bartges, J.W. | Osborne, C.A. | Felice, L.J. | Unger, L.K. | Bird, K.A. | Koehler, L.A. | Chen, M.
Urine uric acid-to-urine creatinine ratios (UUA:UC), urine uric acid concentrations, urine uric acid concentrations corrected for glomerular filtration rate, and urinary uric acid fractional excretions were compared with 24-hour urinary uric acid excretions measured in 6 healthy adult female Beagles. Comparisons, using correlation analysis, were made when dogs consumed a 10.4% protein (dry weight), casein-based diet and a 31.4% protein (dry weight), meat-based diet. The UUA:UC, urine uric acid concentrations corrected for glomerular filtration rate, and urinary uric acid fractional excretions were not reliable estimates of 24-hour urinary uric acid excretions during consumption of either diet. Urine uric acid concentrations in samples collected 2, 4, 6, and 24 hours after initiation of collection correlated with 24-hour urinary uric acid excretions when dogs consumed the casein-based diet; correlation was not found at any time interval when dogs consumed the meat-based diet. Therefore, determination of 24-hour urinary uric acid excretion is recommended because UUA:UC are unreliable.
Mostrar más [+] Menos [-]Evaluation of quantitative acid-base balance and determination of unidentified anions in swine
1994
Frischmeryer, K.J. | Moon, P.F.
Arterial blood samples were collected from 19 anesthetized pigs before and after hemorrhage was induced. Blood gas tensions and concentrations of sodium, potassium, chloride, lactate, and total protein were measured. Results indicated that hydrogen ion (H+) concentration calculated from a specific formula was a biased and imprecise estimate of measured H+ concentration. The bias was 5.45 nEq/L, with limits of agreement from -7.92 to 18.83 nEq/L. Because albumin is the fraction of plasma protein most important in acid-base balance, the agreement between predicted and measured H+ concentration was reevaluated, using an albumin charge estimate and a reference swine albumin-to-globulin ratio. This improved the ability of the formula to predict H+ concentration; the bias decreased to 1.33 nEq/L with limits of agreement from -12.16 to 9.49 nEq/L. The formula and a simplified approach for clinical application were biased and unacceptably imprecise estimators of lactate (L-) concentration. The formula approach underestimated L- concentration by 2.8 (-12.4, 6.7) mEq/L, whereas the simplified method overestimated L- concentration by 5.0 (-3.8, 13.9) mEq/L.
Mostrar más [+] Menos [-]