Refinar búsqueda
Resultados 1-3 de 3
Comparison of cardiac output measured by use of computed tomography and thermodilution in dogs
2017
Tenebaum, Sharon | Garcia-Pereira, Fernando L. | Berry, Clifford R. | Obert, Tori
OBJECTIVE To compare cardiac output (CO) measured by use of CT coronary angiography and thermodilution (criterion-referenced standard) at various CO values, record adverse effects, and determine the time needed to measure CO. ANIMALS 5 healthy purpose-bred Beagles (2 males and 3 females). PROCEDURES A prospective nonrandomized crossover study was conducted. Dogs were premedicated with butorphanol tartrate (0.2 mg•kg−1, IM). Anesthesia was induced by IV administration of etomidate (1 to 2 mg•kg−1) and midazolam (0.25 mg•kg−1). Orotracheal intubation was performed, and anesthesia was maintained by administration of isoflurane. The CO was determined by use of thermodilution and by use of CT at 3 CO values. Dobutamine was infused at various rates to obtain the 3 CO values. RESULTS 13 values were obtained and analyzed. The mean ± SD difference between methods was 0.09 ± 0.71 L•min−1 (95% confidence interval [CI], 0.52 to −0.34 L•min−1). Only 1 of 13 values was located on the 100% agreement line (ie, 0 line), 7 of 13 values were located within the 95% CI, and 5 of 13 values were outside the 95% CI. CONCLUSIONS AND CLINICAL RELEVANCE For this study, there was poor agreement between the 2 methods. The 95% CI interval was 0.52 to −0.34 L•min−1, and 5 of 13 values were outside the 95% CI. Therefore, results for the CT method appeared to be inappropriate for use in making clinical decisions.
Mostrar más [+] Menos [-]Comparison of left and right ventricular stroke volume of dogs calculated on the basis of morphology and blood flow determined by use of cardiac magnetic resonance imaging
2017
Dennler, Matthias | Richter, Henning | Matos, Jose Novo | Toaldo, Marco Baron | Campagna, Ivo U. | Glaus, Tony M. | Kircher, Patrick R.
OBJECTIVE To compare stroke volume (SV) calculated on the basis of cardiac morphology determined by MRI and results of phase-contrast angiography (PCA) of ventricular inflow and outflow in dogs. ANIMALS 10 healthy Beagles. PROCEDURES Cardiac MRI was performed twice on each Beagle. Cine gradient echo sequences of both ventricles in short-axis planes were used for morphological quantification of SVs by assessment of myocardial contours. From the long-axis plane, SVs in 4-chamber and left ventricular 2-chamber views were acquired at end diastole and end systole. For calculation of SV on the basis of blood flow, PCA was performed for cardiac valves. RESULTS Mean ± SD values for SV quantified on the basis of blood flow were similar in all valves (aortic, 17.8 ± 4.1 mL; pulmonary, 17.2 ± 5.4 mL; mitral, 17.2 ± 3.9 mL; and tricuspid, 16.9 ± 5.1 mL). Morphological quantification of SV in the short-axis plane yielded significant differences between left (13.4 ± 2.7 mL) and right (8.6 ± 2.4 mL) sides. Morphological quantification of left ventricular SV in the long-axis plane (15.2 ± 3.3 mL and 20.7 ± 3.8 mL in the 4- and 2-chamber views) yielded variable results, which differed significantly from values for flow-based quantification, except for values for the morphological 4-chamber view and PCA for the atrioventricular valves, for which no significant differences were identified. CONCLUSIONS AND CLINICAL RELEVANCE In contrast to quantification based on blood flow, calculation on the basis of morphology for the short-axis plane significantly underestimated SV, probably because of through-plane motion and complex right ventricular anatomy.
Mostrar más [+] Menos [-]Use of gadoxetic acid for computed tomographic cholangiography in healthy dogs
2017
Chau, Jennifer | Podadera, Juan M. | Young, Alex C. | Makara, Mariano A.
OBJECTIVE To evaluate the effect of gadoxetic acid (contrast) dose on biliary tract enhancement, determine the optimal time after contrast injection for CT image acquisition, and assess the feasibility of CT cholangiography in sedated dogs. ANIMALS 8 healthy dogs. PROCEDURES The study had 2 parts. In part 1, 4 dogs were anesthetized and underwent CT cholangiography twice. Gadoxetic acid was administered IV at a low dose (0.025 mmol/kg) for the first procedure and high dose (0.3 mmol/kg) for the second procedure. Serial CT scans were obtained at predetermined times after contrast injection. In part 2, 4 dogs were sedated and underwent CT angiography 85 minutes after IV administration of the high contrast dose. Contrast enhancement of the biliary tract on all scans was objectively assessed by measurement of CT attenuation and qualitatively assessed by use of a subjective 4-point scoring system by 3 independent reviewers. All measurements were compared over time and between contrast doses for the dogs of part 1. Subjective measurements were compared between the sedated dogs of part 2 and anesthetized dogs of part 1. RESULTS Enhancement of the biliary tract was positively associated with contrast dose and time after contrast injection. Optimal enhancement was achieved 65 minutes after contrast injection. Subjective visualization of most biliary structures did not differ significantly between sedated and anesthetized dogs. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated CT cholangiography with gadoxetic acid was feasible in sedated dogs. The high contrast dose provided better visualization of biliary structures than the low dose; CT scans should be obtained 65 minutes after contrast injection.
Mostrar más [+] Menos [-]