Refinar búsqueda
Resultados 1-10 de 31
Influence of α-lipoic acid on morphology of organs of rabbits fed a high fat diet with the addition of oxidised rapeseed oil Texto completo
2017
Stawiarska-Pięta Barbara | Zalejska-Fiolka Jolanta | Wyszyńska Magdalena | Kleczka Anna | Janiga Beata | Grzegorzak Natalia | Birkner Ewa
Introduction: The aim of the study was to assess the influence of α-lipoic acid (ALA) on the morphology of the aorta and liver of rabbits fed high fat diet with addition of oxidised (ORO) and non-oxidised rapeseed oil (N-ORO).
Mostrar más [+] Menos [-]Modification of a haematoxylin, eosin, and natural saffron staining method for the detection of connective tissue Texto completo
2021
Ceccopieri, Cassandra | Skonieczna, Joanna | Madej, Jan P.
Modification of a haematoxylin, eosin, and natural saffron staining method for the detection of connective tissue Texto completo
2021
Ceccopieri, Cassandra | Skonieczna, Joanna | Madej, Jan P.
The aim of our study was to optimise an existing staining procedure: haematoxylin-eosin saffron (HES). The method follows the classical haematoxylin and eosin protocol with the addition of a staining step using natural saffron to better identify the collagen fibres. The saffron solution was obtained by dissolving ground saffron stigmas in absolute alcohol. In order to test the HES method for its staining ability on four main types of collagen (I, II, III, and IV), specific tissues (skin, tooth, cartilage, aorta, spleen, and penis) were chosen. The procedure showed a sharp differentiation between muscle, stained red or pink, and connective tissue, stained bright yellow or orange. HES allows the diagnosis of reticulin fibrosis undetected in HE and in previous saffron staining procedures. HES represents an advantageous alternative to HE staining giving highly reproducible results with high diagnostic value.
Mostrar más [+] Menos [-]Modification of a haematoxylin, eosin, and natural saffron staining method for the detection of connective tissue Texto completo
2021
Ceccopieri Cassandra | Skonieczna Joanna | Madej Jan P.
The aim of our study was to optimise an existing staining procedure: haematoxylin-eosin saffron (HES). The method follows the classical haematoxylin and eosin protocol with the addition of a staining step using natural saffron to better identify the collagen fibres.
Mostrar más [+] Menos [-]Specific contrast ultrasound using sterically stabilized microbubbles for early diagnosis of thromboembolic disease in a rabbit model Texto completo
2014
Vlasín, Michal | Lukác, Robert | Kauerová, Zuzana | Kohout, Pavel | Mašek, Josef | Bartheldyová, Eliska | Koudelka, Stepán | Korvasová, Zina | Plocková, Jana | Hronová, Nikola | Turánek, Jaroslav
Specific contrast ultrasound is widely applied in diagnostic procedures on humans but remains underused in veterinary medicine. The objective of this study was to evaluate the use of microbubble-based contrast for rapid ultrasonographic diagnosis of thrombosis in small animals, using male New Zealand white rabbits (average weight about 3.5 kg) as a model. It was hypothesized that the use of microbubble-based contrast agents will result in a faster and more precise diagnosis in our model of thrombosis. A pro-coagulant environment had been previously established by combining endothelial denudation and external vessel wall damage. Visualization of thrombi was achieved by application of contrast microbubbles [sterically stabilized, phospholipid-based microbubbles filled with sulfur hexafluoride (SF6) gas] and ultrasonography. As a result, rapid and clear diagnosis of thrombi in aorta abdominalis was achieved within 10 to 30 s (mean: 17.3 s) by applying microbubbles as an ultrasound contrast medium. In the control group, diagnosis was not possible or took 90 to 180 s. Therefore, sterically stabilized microbubbles were found to be a suitable contrast agent for the rapid diagnosis of thrombi in an experimental model in rabbits. This contrast agent could be of practical importance in small animal practice for rapid diagnosis of thrombosis.
Mostrar más [+] Menos [-]Evaluation of glomerular filtration rate by use of dynamic computed tomography and Patlak analysis in clinically normal cats Texto completo
2011
Chang, Jinhwa | Ahn, Sejoon | Choi, Sooyoung | Lee, Heechun | Chang, Dongwoo | Choi, Hojung | Lee, Youngwon
Objective: To obtain quantitative variables of the abdominal aorta and both kidneys on the basis of time-attenuation curves (TACs) and to measure glomerular filtration rate (GFR) for each kidney and the global GFR in clinically normal cats by use of dynamic computed tomography (CT) and Patlak analysis. Animals: 9 healthy cats. Procedures: All the cats were anesthetized with propofol. Anesthesia was maintained by administration of isoflurane, and CT examination was performed in the anesthetized cats. The TACs and renal volume were measured by use of the baseline precontrast and single-slice dynamic scans. The CT-GFR of each kidney and the global CT-GFRs were calculated via Patlak plot analysis. Results: CT-GFR results from 7 cats were valid. Peak aortic enhancement was detected between 9.0 and 14.0 seconds after iohexol injection, and the initial peak time of renal parenchymal enhancement was 15 to 24 seconds after iohexol injection. Mean ± SD global GFR was 2.06 ± 0.62 mL/min/kg. Mean ± SD CT-GFR of the right and left kidneys was 0.97 ± 0.32 mL/min/kg and 1.05 ± 0.31 mL/min/kg, respectively. Conclusions and Clinical Relevance: The CT-GFR method can be rapidly and conveniently performed in clinically normal cats. This combined structural-functional approach provided physiologic and morphological information on the kidneys of cats.
Mostrar más [+] Menos [-]Effects of ketamine-xylazine intravenous bolus injection on cardiovascular function in rabbits Texto completo
2010
Baumgärtner, Christine | Bollerhey, Melanie | Ebner, Johanna | Laacke-Singer, Lien | Schuster, Tibor | Erhardt, Wolf
The direct effects of ketamine-xylazine (KET-XYL) on vascular function have not been investigated in rabbits. The short-term cardiovascular effects of intravenous (IV) KET-XYL bolus injection, therefore, should be investigated using vascular ultrasonography.In this prospective experimental study, KET-XYL anesthesia was induced IV in 9 female New Zealand White rabbits before 3 defined test bolus injections of KET-XYL were given IV. Before and for 10 min after each KET-XYL injection vascular and hemodynamic variables were recorded at the left common carotid artery (ACC) after the 1st injection, and at the abdominal aorta (AA) after the 2nd injection. Echocardiography was performed after the 3rd injection to investigate changes in cardiac parameters.Ketamine-xylazine IV caused a significant increase in vessel diameter at the ACC and AA. Average volumetric flow significantly decreased at the ACC and pulsatility index significantly decreased at the AA. Fractional shortening (FS) and heart rate significantly decreased, while mean arterial blood pressure initially increased.Bolus injections of KET-XYL IV produced a transient vasodilatation at the ACC and AA. Despite central vasodilatation, bradycardia, and decrease of FS and average volumetric flow (VFave), mean arterial blood pressure did not significantly decrease indicating well-preserved cardiovascular compensatory mechanism after the ratio and doses of KET-XYL IV bolus injections used in this study.
Mostrar más [+] Menos [-]In vitro ultrasonographic appearance of the normal and verminous equine aorta, cranial mesenteric artery, and its branches
1989
Wallace, K.D. | Selcer, B.A. | Tyler, D.E. | Brown, J.
Ninety-one equine aortic and cranial mesenteric arterial segments were evaluated ultrasonographically in a water bath. On the basis of pathologic evidence of verminous arteritis, arterial segments were classified into 4 categories, and the ultrasonographic characteristics of each group were evaluated. Normal arteries (class 1) were ultrasonographically characterized by a smooth luminal surface layer and uniform wall thickness and echogenicity. Arteries with only histopathologic evidence of verminous arteritis (class 2) were ultrasonographically characterized by a smooth luminal surface layer, uniform thickness, uniform echogenicity, and the presence of a hyperechoic luminal layer. Arteries with both gross and histopathologic evidence of verminous arterities (class 3) were characterized ultrasonographically by an irregular luminal surface layer, varying wall thickness, varying wall echogenicity, and the presence of a hyperechoic luminal layer. The ultrasonographic characteristics of arteries with luminal thrombosis (class 4) were an irregular luminal surface, varying wall thickness, and nonuniform echogenicity.
Mostrar más [+] Menos [-]Correlation of the ratio of caudal vena cava diameter and aorta diameter with systolic pressure variation in anesthetized dogs Texto completo
2016
Meneghini, Caterina | Rabozzi, Roberto | Franci, Paolo
OBJECTIVE To evaluate the correlation coefficient of the ratio between diameter of the caudal vena cava (CVC) and diameter of the aorta (Ao) in dogs as determined ultrasonographically with systolic pressure variation (SPV). ANIMALS 14 client-owned dogs (9 females and 5 males; mean ± SD age, 73 ± 40 months; mean body weight, 22 ± 7 kg) that underwent anesthesia for repair of skin wounds. PROCEDURES Anesthesia was induced. Controlled mechanical ventilation with a peak inspiratory pressure of 8 cm H2O was immediately started, and SPV was measured. During a brief period of suspension of ventilation, CVC-to-Ao ratio was measured on a transverse right-lateral intercostal ultrasonographic image obtained at the level of the porta hepatis. When the SPV was ≥ 4 mm Hg, at least 1 bolus (3 to 4 mL/kg) of Hartmann solution was administered IV during a 1-minute period. Bolus administration was stopped and the CVC-to-Ao ratio measured when SPV was < 4 mm Hg. Correlation coefficient analysis was performed. RESULTS 28 measurements were obtained. The correlation coefficient was 0.86 (95% confidence interval, 0.72 to 0.93). Mean ± SD SPV and CVC-to-Ao ratio before bolus administration were 7 ± 2 mm Hg and 0.52 ± 0.16, respectively. Mean ± SD SPV and CVC-to-Ao ratio after bolus administration were 2 ± 0.6 mm Hg and 0.91 ± 0.13, respectively. CONCLUSIONS AND CLINICAL RELEVANCE In this study, the CVC-to-Ao ratio was a feasible, noninvasive ultrasonographically determined value that correlated well with SPV.
Mostrar más [+] Menos [-]Two-dimensional left atrium–to–aorta ratios and left ventricular M-mode transthoracic echocardiographic measurements in clinically normal adult Dachshunds Texto completo
2016
Lim, Chee Kin | Fosgate, Geoffrey T. | Green, Henry W III | Kirberger, Robert M.
OBJECTIVE To estimate the left atrium–to–aorta ratio (LA:Ao) and establish 95% prediction intervals for left ventricular M-mode transthoracic echocardiographic measurements in clinically normal adult Dachshunds. ANIMALS 40 healthy Dachshunds. PROCEDURES For each dog, 3 standard 2-D echocardiographic methods (diameter, circumference, and cross-sectional area) were used to measure the left atrium and aorta and calculate the LA:Ao from right parasternal short axis (RPSA) images obtained at the level of the aortic valve cusps. Left ventricular M-mode measurements were acquired from RPSA images obtained at the chordal level immediately below the mitral valve. Descriptive data were generated, and the 95% prediction intervals were calculated by use of an allometric scaling equation and linear regression and compared with those calculated on the basis of data obtained from dogs of multiple breeds in a previous study.RESULTS The mean (SD) LA:Ao was 1.40 (0.13), 2.09 (0.17), and 2.85 (0.48) for the diameter, circumference, and cross-sectional area methods, respectively. The 95% prediction intervals for the left ventricular M-mode measurements determined by an allometric scaling equation on the basis of Dachshund-specific data were narrower than those determined on the basis of data obtained from dogs of multiple breeds. For that allometric equation, scaling exponents on the basis of Dachshund-specific data ranged from 0.129 to 0.397 and did not absolutely conform to the presumed index for linear measurements (ie, body weight0.333). CONCLUSIONS AND CLINICAL RELEVANCE The LA:Aos and 95% prediction intervals calculated in this study can be used as preliminary guidelines for echocardiographic measurements of clinically normal Dachshunds.
Mostrar más [+] Menos [-]Estimation of intrathoracic arterial diameter by means of computed tomographic angiography in Hispaniolan Amazon parrots Texto completo
2011
Beaufrere, Hugues | Rodríguez, Daniel | Pariaut, Romain | Gaschen, Lorrie | Schnellbacher, Rodney | Nevarez, Javier G. | Tully, ThomasN. Jr
Objective--To establish a computed tomography (CT)-angiography protocol and measure the diameters of major arteries in parrots. Animals--13 Hispaniolan Amazon parrots (Amazona ventralis). Procedures--16-slice CT scanning was used to measure the apparent diameter of the ascending aorta, abdominal aorta, pulmonary arteries, and brachiocephalic trunk. Before scanning, all birds underwent ECG and echocardiographic assessment and were considered free of detectable cardiovascular diseases. Each bird was anesthetized, and a precontrast helical CT scan was performed. Peak aortic enhancement was established with a test bolus technique via dynamic axial CT scan over a predetermined single slice. An additional bolus of contrast medium was then injected, and a helical CT-angiography scan was performed immediately afterward. Arterial diameter measurements were obtained by 2 observers via various windows before and after injection, and intra- and interobserver agreement was assessed. Results--Reference limits were determined for arterial diameter measurements before and after contrast medium administration in pulmonary, mediastinal, and manual angiography windows. Ratios of vertebral body diameter to keel length were also calculated. Intraobserver agreement was high (concordance correlation coefficients ≥ 0.95); interobserver agreement was medium to high (intraclass correlation coefficients ≥ 0.65). Conclusions and Clinical Relevance--CT-angiography was safe and is of potential diagnostic value in parrots. We recommend performing the angiography immediately after IV injection of 3 mL of iohexol/kg. Arterial diameter measurements at the described locations were reliable.
Mostrar más [+] Menos [-]Use of pulsed-wave Doppler echocardiography to determine aortic and pulmonary velocity and flow variables in clinically normal dogs
1991
Brown, D.J. | Knight, D.H. | King, R.R.
Transcutaneous pulsed-wave Doppler echocardiography was used to obtain velocity signals from the aortic and pulmonary roots of clinically normal adult dogs tranquilized with acepromazine. Doppler-derived variables included peak ejection velocity, ejection time, and velocity-time integral. The cross-sectional areas of the left and right ventricular outflow tracts were estimated from diameters of the respective orifices measured from two-dimensional echocardiographic images. These data were used to calculate stroke volume and cardiac output for each ventricle. Linear, single variable regressions of ejection time, velocity-time integral, and peak velocity with body weight showed no significant correlations. Significant correlations existed between body weight and estimated left and right ventricular stroke volume and cardiac output. A close correspondence existed between pulmonary and aortic determinations of velocity-time integral, stroke volume, and cardiac output. These results provide an initial framework for interpretation of clinical data by veterinary cardiologists.
Mostrar más [+] Menos [-]