Refinar búsqueda
Resultados 1-2 de 2
Comparison of the bacteriostatic effects of quaternary ammonium compounds and their combinations on a dairy farm environment and the microbial contamination of dairy products
2021
Chen, Nannan | Liu, Shanshan | Liu, Yu | Bai, Tongtong | Jia, Lihua | Wang, Li | Yue, Shan | Wu, Chenhua | Huang, Wenjing | Gao, Li | Fu, Jinlei | Liu, Siyu | Zhao, Tong | Li, Juan | Zhang, Yuntao | Zhu, Zhanbo
Disinfection is key for controlling microbial contamination and ensuring the safe production of milk and dairy products. In this study, we developed a new disinfection method using quaternary ammonium surfactant N-dodecyl-2-(pyridin-1-yl) acetamide chloride as the main component to form a bactericidal complex with either chlorhexidine acetate or glutaraldehyde, and we evaluated the bactericidal effects, safety, and clinical application value of the compound disinfectants. An in vivo acute oral toxicity assay in mice showed an LD50 > 5000 mg/kg body weight without abnormality in pathological tissue sections. Comparison with commercially available products also showed that they have outstanding bactericidal effects. Clinical trials proved that the compound disinfectants have excellent bactericidal effects on the air and ground of the dairy farm and on the skin of cattle, especially in a dairy farm environment. Our findings confirm that the new compound disinfectants have excellent bactericidal performance and are safe to use as disinfectants to prevent mastitis and contamination of the cattle farm environment.
Mostrar más [+] Menos [-]Evaluation of two benchtop blood gas analyzers for measurement of electrolyte concentrations in venous blood samples from dogs
2021
OBJECTIVE To assess agreement between 2 benchtop blood gas analyzers developed by 1 manufacturer (BGA 1 and BGA 2 [a newer model with reduced maintenance requirements]) and a reference chemistry analyzer for measurement of electrolyte (sodium, chloride, and potassium) in blood samples from dogs. ANIMALS 17 healthy staff- and student-owned dogs and 23 client-owned dogs admitted to an emergency and intensive care service. PROCEDURES Blood collected by venipuncture was placed in lithium heparin–containing tubes. Aliquots were analyzed immediately with each BGA. Samples were centrifuged, and plasma was analyzed with the reference analyzer. Results for each BGA were compared with results for the reference analyzer by Passing-Bablok regression analysis. Percentage differences between BGA and reference analyzer results were compared with published guidelines for total allowable error. RESULTS Proportional bias was detected for measurement of chloride concentration (slope, 0.7; 95% CI, 0.7 to 0.8), and constant positive bias was detected for measurement of chloride (y-intercept, 34, mmol/L; 95% CI, 16.9 to 38 mmol/L) and potassium (y-intercept, 0.1 mmol/L; 95% CI, 0.1 to 0.2 mmol/L) concentrations with BGA 1. There was no significant bias for measurement of potassium or chloride concentration with BGA 2 or sodium concentration with either BGA. Differences from the reference analyzer result exceeded total allowable error guidelines for ≥ 1 sample/analyte/BGA, but median observed measurement differences between each BGA and the reference analyzer did not. CONCLUSIONS AND CLINICAL RELEVANCE Good agreement with reference analyzer results was found for measurement of the selected electrolyte concentrations in canine blood samples with each BGA.
Mostrar más [+] Menos [-]