Rapid purification of a 110-kilodalton hemolysin of Actinobacillus pleuropneumoniae by monoclonal antibody-affinity chromatography
1992
Ma, J. | Inzana, T.J.
An efficient, single-step method for purification of the 110-kilodalton (kDa) hemolysin of Actinobacillus pleuropneumoniae was developed. An immunoaffinity column was made by cross-linking murine monoclonal antibody 8C2 to the 110-kDa hemolysin of A pleuropneumoniae strain J45 serotype 5 to protein A-agarose beads. Purified hemolysin with high hemolytic activity was obtained after washing the column with phosphate-buffered saline solution, and eluting the hemolysin with 50 mM diethylamine, pH 11.0. The same column was also used to purify the hemolysin from A pleuropneumoniae strain 4074 serotype 1. The purification procedure could be completed within 5 hours, and almost 50% of the total hemolytic activity and hemolysin protein was recovered in pure form.
Mostrar más [+] Menos [-]Comparative aspects and sex differentiation of plasma sulfamethazine elimination and metabolite formation in rats, rabbits, dwarf goats, and cattle
1992
Witkamp, R.F. | Yun, H.I. | Klooster, G.A.E. van't | Mosel, J.F. van | Mosel, M. van | Ensink, J.M. | Noordhoek, J. | Miert, A.S.J.P.A.M. van
Plasma disposition and urinary recovery of sulfamethazine (SMZ), its N4-acetylated metabolite (N4AcSMZ), and 2 of its hydroxylated metabolites--5-hydroxysulfamethazine 5OHSMZ) and 6-hydroxymethylsulfamethazine (6CH2OHSMZ)--were determined in either sex of 4 animal species: rats, dwarf goats, rabbits, and cattle. Rats, rabbits, and dwarf goats had significant (P < 0.01) sex difference in SMZ plasma clearance. Male rats had higher plasma clearance than did female rats, and excreted higher amounts of the hydroxy metabolites and lower amounts of N4AcSMZ. The N4AcSMZ metabolite was predominant in plasma and urine of rabbits. Male rabbits had higher plasma clearance than did female rabbits, but differences in metabolite profile were not apparent. With regard to plasma SMZ elimination, the situation in goats was opposite to that in rats. Male goats had considerably lower clearance than did female goats. This was associated with a lower hydroxylation rate in males. Plasma half-life of SMZ in cows was lower than that in bulls, probably because of a smaller distribution volume in cows. Compared with elimination via urine, elimination via milk was negligible in cows. Significant differences in metabolite profiles were not found between bulls and cows. Similar to those in rats and mice, hormone-dependent xenobiotic metabolic pathways may exist in other species. Depending on species and xenobiotic compound residue concentrations of xenobiotics, their metabolites, or both may differ with sex of the animal, or may be altered after treatment with anabolic hormones.
Mostrar más [+] Menos [-]Selective measurement of lipoprotein lipase and hepatic triglyceride lipase in heparinized plasma from horses
1992
Watson, T.D.G. | Burns, L. | Packard, C.J. | Shepherd, J.
Affinity chromatography on heparin sepharose was used to identify 2 lipolytic enzymes in heparinized plasma from horses. One enzyme was typical of hepatic triglyceride lipase (HTGL), because it was resistant to inactivation by high concentrations of NaCl, and it did not require the addition of serum for activity. The other enzyme was identified as lipoprotein lipase (LPL), because of its inactivation at NaCl concentrations in excess of 0.2M, and its dependency on addition of serum as a source of apolipoprotein C-II activator. The enzymes were purified by 347- (HTGL) and 442- (LPL) fold, with yields of 54 and 58%, respectively. The partially purified enzymes were used to design incubation conditions that gave optimal activities for each enzyme in vitro. A selective assay was then developed for direct measurement of LPL and HTGL activities in heparinized plasma from horses. Analysis of HTGL took advantage of the almost complete inactivition of LPL when serum cofactor was excluded from the assay at the NaCl concentration that gave optimal HTGL activity. Prior incubation of heparinized plasma with sodium dodecyl sulfate to inhibit HTGL was necessary for measurement of LPL, because HTGL retained 67% of its activity at the NaCl concentration required for optimal LPL activity. Activity of each enzyme was measured in heparinized plasma from 12 Shetland ponies. The mean activity +/- SD for LPL was 3.22 +/- 1.04 micromoles of fatty acids/ml of heparinized plasma/h (micromoles of FA/ml/h). The mean activity for HTGL was 4.9 +/- 1.56 micromoles of FA/ml/h. The performance of the assay was assessed by replicate analysis of pools of each enzyme with high and low activities. The intra-assay coefficient of variation ranged between 3.4 and 8.7% (n = 10), and the interassay coefficient of variation ranged between 5.2 and 10.7% (n = 7) for the same pools analyzed over 7 weeks.
Mostrar más [+] Menos [-]Purification of the ninth component of the bovine complement cascade
1992
Eisenschenk, F.C. | Houle, J.J. | Hoffmann, E.M.
Conditions for purification of the ninth component of bovine complement (C9) were established. The conditions for binding and elution from diethylaminoethyl cellulose and hydroxylapatite were different than for human C9. Serum albumin, a frequent contaminant of bovine C9 preparations, was removed by chromatography on reactive-red agarose. The calculated molecular weight of bovine C9 was 66,000, and reduction with 2-mercaptoethanol affected its migration on polyacrylamide gel electrophoresis. Some preparations of bovine C9 migrated as 2 bands when partially reduced, but extensively reduced preparations had a single band.
Mostrar más [+] Menos [-]Use of enzyme immunoassay and reverse-phase high-performance liquid chromatography to detect and confirm identity of dexamethasone in equine blood
1992
Friedich, A. | Schulz, R. | Meyer, H.D.
An enzyme immunoassay (EIA) was developed for detection of dexamethasone in equine blood. Dexamethasone 21-hemisuccinate-bovine serum albumin was used for immunization of rabbits, and prednisolone 21-hemisuccinate-horseradish peroxidase was used as enzyme conjugate. The assay had sensitivity in the low-picogram range (detection limit, 0.3 pg/well, 50% inhibition of binding at 4.5 +/- 0.7 pg/well). Apart from cortisol, which was recognized by the antiserum at concentration > 8.5 ng/ml, the dexamethasone antiserum failed to interfere with endogenous steroids, but cross-reacted with triamcinolone, flumethasone, and betamethasone. Thus, the antiserum was used to perform simultaneous screening for these synthetic glucocorticoids and to confirm their identity by combining reverse-phase high-performance liquid chromatography (RP-HPLC) and EIA. The immunoreactivity obtained by direct serum measurements was characterized by means of 2 independent RP-HPLC systems. Serum extracts were submitted to RP-HPLC systems I and II, and the fractions were tested by EIA. Immunoreactive peaks were identified by comparing their retention time with that of the standard glucocorticoids used for calibration. Coinjection of an internal standard (methylprednisolone) in RP-HPLC system II yielded reproducible relative retention times. The effectiveness of the test system was evaluated, using blood from a horse treated with commonly used veterinary preparations of dexamethasone. Administration of the free alcohol of dexamethasone and of dexamethasone 21-trioxaundecanoate, both given IV, was detected, and the identity of each was confirmed for up to 48 hours. Intramuscular administration of dexamethasone 21-isonicotinate was continued for at least 14 days after injection of a therapeutic dose. The technique provided higher sensitivity and practicability than do analytic techniques currently available for glucocorticoid testing in horses and proved reliable in confirming the identity of dexamethasone, triamcinolone, flumethasone, and betamethasone in equine blood samples.
Mostrar más [+] Menos [-]Pharmacokinetics of intravenously and orally administered pyrimethamine in horses
1992
Clarke, C.R. | Burrows, G.E. | MacAllister, C.G. | Spillers, D.K. | Ewing, P. | Lauer, A.K.
Single-dose pharmacokinetic variables of pyrimethamine were studied in horses. Pyrimethamine (1 mg/kg of body weight) was administered IV and orally to 6 adult horses, and plasma samples were obtained at frequent intervals thereafter. Plasma pyrimethamine concentration was assayed by gas chromatography, and concentration-time data were analyzed, using a pharmacokinetic computer program. The IV and oral administration data were best described by 3-compartment and 1-compartment models, respectively. The median volume of distribution at steady state after iv administration was 1,521 ml/kg and the median elimination half-time was 12.06 hours. Mean plasma concentration after oral administration fluctuated between a maximal concentration of 0.18 microgram/ml and 0.09 microgram/ml (24 hours after dosing). Bioavailability after oral administration was 56%.
Mostrar más [+] Menos [-]Evaluation of a subunit vaccine for bovine adenovirus type 3
1992
York, I.A. | Thorsen, J.
The hexon subunit of bovine adenovirus serotype 3 (BAV-3) was purified by use of anion-exchange chromatography. A vaccine composed of the purified hexon in immune-stimulating complexes was administered and induced high titer of virus-neutralizing antibody in rabbits and calves.