Evaluation of tissue Doppler imaging for regional quantification of radial left ventricular wall motion in healthy horses
2013
Decloedt, Annelies | Verheyen, Tinne | Sys, Stanislas | Clercq, Dominique de | Loon, Gunther van
Objective: To compare the feasibility and repeatability of tissue Doppler imaging (TDI) for quantification of radial left ventricular (LV) velocity and deformation from different imaging planes and to correlate cardiac event timing data obtained by TDI to M-mode and pulsed-wave Doppler-derived time intervals in horses. Animals: 10 healthy adult horses. Procedures: Repeated echocardiography was performed by 2 observers from right and left parasternal short-axis views at papillary muscle and chordal levels. The TDI measurements of systolic and diastolic velocity, strain rate, strain peak values, and timing were performed in 8 LV wall segments (LV free wall and interventricular septum from right parasternal views; left and right region of LV wall from left parasternal views). The inter- and intraobserver within- and between-day variability and measurement variability were assessed. The correlation between TDI-based measurements and M-mode and pulsed-wave Doppler-based time measurements was calculated. Results: TDI measurements of velocity, strain rate, and strain were feasible in each horse, although deformation could often not be measured in the LV free wall. Systolic and diastolic time intervals could be determined with low to moderate variability, whereas peak amplitude variability ranged from low to high. The TDI-based time measurements were significantly correlated to M-mode and pulsed-wave Doppler measurements. Conclusions and Clinical Relevance: TDI measurements of radial LV velocity and deformation were feasible with low to moderate variability in 8 LV segments. These measurements can be used for evaluating LV function in further clinical studies.
Mostrar más [+] Menos [-]Comparison of echocardiography with dual-source computed tomography for assessment of left ventricular volume in healthy Beagles
2013
Lee, Miyoung | Park, Nohwon | Lee, Seungyeon | Lee, Ahra | Jung, Joohyun | Kim, Youngjun | Ko, Sungmin | Kim, Hwiyool | Jeong, Soonwuk | Eom, Kidong
Objective: To compare echocardiographic measurements of left ventricular (LV) volume obtained via a modified Simpson or Teichholz method with those obtained via dual-source CT (DSCT). Animals: 7 healthy Beagles. Procedures: Each dog was anesthetized for DSCT; LV volume was determined from contrast-enhanced images of the LV lumen during all phases of contraction. Echocardiography was performed with dogs awake and anesthetized. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume, and ejection fraction were measured via a modified Simpson method and Teichholz method. Each dog was anesthetized twice with a 1-week interval between anesthetic sessions. Results: Results obtained while dogs were anesthetized revealed that the modified Simpson method underestimated LV volume (mean ± SD EDV, 24.82 ± 2.38 mL; ESV, 12.24 ± 1.77 mL), compared with that estimated by the Teichholz method (EDV, 32.57 ± 2.85 mL; ESV, 14.87 ± 2.09 mL) or DSCT (EDV, 34.14 ± 1.57 mL; ESV, 16.71 ± 0.76 mL). Ejection fraction (modified Simpson method, 48.53% ± 4.24%; Teichholz method, 54.33% ± 4.26%; DSCT, 51.00% ± 2.71%) differed significantly among the 3 methods. Echocardiographic results obtained while dogs were awake revealed that EDV, ESV, and stroke volume differed significantly between the modified Simpson and Teichholz methods. Conclusions and Clinical Relevance: LV volume determined via the Teichholz method was more similar to that determined via DSCT than was the LV volume determined via the modified Simpson method. The modified Simpson method underestimated LV volume, compared with that obtained via the Teichholz method, in both anesthetized and awake dogs.
Mostrar más [+] Menos [-]Assessment of left ventricular volumes by use of one-, two-, and three-dimensional echocardiography versus magnetic resonance imaging in healthy dogs
2013
Meyer, Judith | Wefstaedt, Patrick | Dziallas, Peter | Beyerbach, Martin | Nolte, Ingo | Hungerbühler, Stephan O.
Objective-To quantify left ventricle (LV) volumes by use of 1-D, 2-D, and 3-D echocardiography versus MRI in dogs. Animals-10 healthy Beagles. Procedures-During anesthesia, each dog underwent an echocardiographic examination via the Teichholz method, performed on the basis of standard M-mode frames (1-D); the monoplane Simpson method of disk (via 2-D loops); real-time triplane echocardiography (RTTPE) with a 3-D probe; and real-time 3-D echocardiography with a 3-D probe. Afterward, cardiac MRI was performed. Values for the LV end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) were compared between each echocardiographic method and the reference method (cardiac MRI). Results-No significant differences for EDV, ESV, and EF were detected between RTTPE and cardiac MRI. Excellent correlations (r = 0.97, 0.98, and 0.95 for EDV, ESV, and EF, respectively) were found between RTTPE and values for cardiac MRI. The other echocardiographic methods yielded values significantly different from cardiac MRI and results correlated less well with results of cardiac MRI for EDV, ESV, and EF. Use of the Teichholz method resulted in LV volume overestimation, whereas the Simpson method of disk and real-time 3-D echocardiography significantly underestimated LV volumes. Conclusions and Clinical Relevance-Use of RTTPE yielded excellent correlations and nonsignificant differences with cardiac MRI and is a suitable method for routine veterinary cardiac examination.