Refinar búsqueda
Resultados 1-10 de 67
Intraocular pressure measurement through two types of plano therapeutic soft contact lenses in dogs.
1995
Miller P.E. | Murphy C.J.
Intraocular pressure (IOP) was measured by use of Mackay-Marg applanation tonometry in 8 normal, manometrically controlled, enucleated, canine eyes with and without 1 of 2 piano therapeutic soft contact lenses (1 and 2) covering the cornea. Differences were not significant between measurements made without a contact lens and those made through either lens at manometer IOP < 30 mm of Hg. At manometer IOP greater than or equal to 30 mm of Hg, use of a contact lens tended to result in a statistically greater (P < 0.05) estimate of IOP than when a lens was not used. This difference, however, achieved only a maximum of 2.6 mm of Hg at the 80 mm of Hg value, and was not regarded as clinically important. Measurements obtained through lens 1 were not significantly different from those obtained through lens 2. The IOP can be accurately estimated in dogs; using the Mackay-Marg tonometer, without removing either type of bandage soft contact lens, thereby avoiding potential disruption of an already compromised cornea.
Mostrar más [+] Menos [-]Comparison of a visual analogue scale and a numerical rating scale for assessment of lameness, using sheep as a model.
1993
Welsh E.M. | Gettinby G. | Nolan A.M.
A study was designed to compare use of an numerical rating scale (NRS) and a visual analogue scale (VAS) for subjective assessment of lameness, using sheep as a model. The NRS consisted of 5 divisions, 0, 1, 2, 3, and 4; 4 of these divisions (1-4) described lameness. The VAS used a 100-mm horizontal line with vertical bars at either end; one end was labeled 'sound' and the other was labeled 'could not be more lame.' Two independent observers graded lameness in 62 sheep, and between- and within-observer differences were assessed for each scoring system to compare the NRS with the VAS. Results indicated no significant differences between the 2 observers scoring lameness, using either the VAS or the NRS. The scores obtained, using the VAS, were not normally distributed, although differences between scores for the 2 observers were. The NRS scores followed a normal distribution pattern. Investigation of repeated measurement for the same sheep, using both scales, revealed no significant difference between either. A comparison of the NRS and VAS scores made by each observer indicated that although correlation was good (observer 1; r = 0.94; observer 2; r = 0.95), there was not perfect agreement. The maximal NRS score of 4 was associated with VAS values > 68 mm, indicating that the NRS divisions did not reflect equal increases in lameness. The VAS and NRS scores for each observer were highly reproducible, although they were more variable for sheep that were regarded as moderately lame. Results indicate that although the NRS and VAS compared favorably with respect to repeatability, reproducibility, and use by 2 observers, the VAS is inherently more sensitive. In addition, the NRS and VAS should not be used interchangeably.
Mostrar más [+] Menos [-]Effect of titanium endoprostheses on bone mineral density measurements, using quantitative computed tomography.
1992
Markel M.D. | Morin R.L. | Roy R.G. | Gottsauner Wolf F. | Chao E.Y.S.
Quantitative computed tomography has been used extensively to measure bone mineral density; particularly in the vertebral column and in the proximal portion of the femur in human beings with osteoporosis. Other potential applications of this technique include evaluation of bone adjacent to metallic endoprostheses and evaluation of fractures as they heal. Unfortunately, metal causes severe image degradation, principally seen as starburst streaking. One method used to decrease these artifacts is by imaging less-attenuating materials, such as titanium alloy. Titanium decreases image degradation sufficiently to allow accurate determination of the geometric properties of cadaveric bone. In our study, the effect of a titanium segmental endoprosthesis on bone mineral density measurement was determined by use of bone specimens from dogs and calibration standards. Titanium decreased the bone mineral density of calibration solutions from 6.8 (500 mg/cm3) to 17.7% (250 mg/cm3), and increased bone mineral density of cortical bone by 5.3%. Titanium did not affect the repeatability of these scans, indicating that the error caused by titanium was systematic and can be corrected. Our data were suggestive that quantitative computed tomography can be used to measure bone mineral density of cortical bone adjacent to titanium endoprostheses, with a predictable increase in density measurement.
Mostrar más [+] Menos [-]Evaluation of an automated system for hemoglobin measurement in animals.
1992
Callan M.B. | Giger U. | Oakley D.A. | Scotti M.V. | Shofer F.S.
In veterinary medicine, PCV determined by centrifugation of blood in a microhematocrit tube is the most common clinical test used to initially assess and monitor anemic and polycythemic animals. In contrast, blood hemoglobin (Hb) concentration, rather than PCV, is generally determined in human patients. One automated system photometrically measures blood Hb concentration after conversion of Hb to azide methemoglobin without dilution and was found to be a simple and accurate instrument for use in human medicine. We evaluated the system for its accuracy in measuring blood Hb concentration in animals by comparing it with standard techniques and for its suitability in veterinary practice. Blood samples, anticoagulated with potassium EDTA, from 78 healthy animals (33 dogs, 17 cats, 13 horses, and 15 cows) and 58 dogs and 4 cats with various blood abnormalities (10 anemia, 11 polycythemia, 21 lipemia, 16 leukocytosis, and 6 icterus) were analyzed. In all species, blood Hb concentration of healthy animals determined by the system was comparable to that measured by standard cyanmethemoglobin methods (ie, an automated counter; rI = 0.987 to 0.998 and a hemoglobin kit, rI = 0.946 to 0.993). The aforementioned system also yielded similar values to those obtained by use of standard methods in anemic, polycythemic, and icteric dogs and cats. Moreover, the system reads the absorbance at 2 wavelengths to correct for turbidity, and therefore, accurately measured Hb concentration in blood samples with severe lipemia (triglycerides concentration > 500 mg/dl) and marked leukocytosis (> 50,000 WBC/microl), whereas other standard Hb techniques are known to give falsely high results. We conclude that the automated system compares favorably to standard methods, and is a simple and accurate instrument to quickly measure Hb concentration in animals.
Mostrar más [+] Menos [-]Electroretinogram and visual-evoked potential measurements in Holstein cows.
1986
Strain G.M. | Olcott B.M. | Hokett L.D.
Evaluation of the wick catheter as used to measure intracompartmental muscle pressure in equine muscle.
1985
McDonnell W.N. | Pascoe P.J. | Lindsay W.A. | Burgess M.L.F.
Bioelectrical impedance and zoometry for body composition analysis in domestic cats.
1992
Stanton C.A. | Hamar D.W. | Johnson D.E. | Fettman M.J.
Zoometric measurements and bioelectrical impedance analysis were evaluated as methods of body composition determination in healthy cats. Zoometric and impedance measurements were taken on 22 anesthetized adult cats of various ages, genders, breeds, and body weights. The cats were then euthanatized. The bodies were processed through a tissue homogenizer and free-catch specimens were taken, freeze-dried, and analyzed for total body water, protein, fat, potassium, and ash content. Stepwise regression analysis was implemented to identify statistically significant relationships between the chemically determined dependent variables (total body water, protein, potassium, fat-free mass, fat mass, and percent body fat) and the zoometric measurements, with or without bioelectrical impedance analysis. Statistical analysis revealed high correlations between the dependent variables and the corresponding predicted values of those variables. Body weight alone was a poor predictor of body composition in these cats. On the basis of these findings, we suggest that zoometric and bioelectrical impedance measurements may serve as practical, noninvasive, simple, and accurate methods for estimating body composition in domestic cats.
Mostrar más [+] Menos [-]PMSG profiles in superovulated and anti-PMSG antiserum treated mice and heifers with enzymeimmunossay.
1991
Katagiri S. | Takahashi Y. | Hishinuma M. | Kanagawa H. | Dochi O. | Takakura H.
Frequency and severity of osteochondrosis in horses with cervical stenotic myelopathy.
1991
Stewart R.H. | Reed S.M. | Weisbrode S.E.
We compared the frequency and severity of osteochondrosis lesions in young Thoroughbred horses with cervical stenotic myelopathy (CSM) vs that in clinically normal Thoroughbreds of the same age. All lesions of the cervical vertebrae and appendicular skeleton were classified histologically as osteochondrosis or nonosteochondrosis and were measured for severity. Minimal sagittal diameter was significantly smaller in horses with CSM from C2 through C6; no difference was detected at C7. Severity of cervical vertebral osteochondrosis was greater in the horses with CSM, however frequency was not different. Frequency and severity of nonosteochondrosis lesions were not different in cervical vertebrae or appendicular skeleton. Frequency and severity of appendicular skeleton osteochondrosis lesions were both greater in horses with CSM. Osteochondrosis and nonosteochondrosis lesions were more severe on facets at sites of compression than on facets at noncompressed sites in horses with CSM. However, compression was also observed at sites with no articular facet lesions. The association of widespread osteochondrosis and spinal canal narrowing with CSM suggests CSM may represent a systemic failure in the development or maturation of cartilage and bone.
Mostrar más [+] Menos [-]Plasma lactate measurements in healthy Beagle dogs.
1987
Evans G.O.