Use of a protected catheter brush for culture of the lower respiratory tract in horses with small airway disease
1991
Grandguillot, L. | Fairbrother, J.M. | Vrins, A.
A protected catheter brush introduced by fiberoptic bronchoscopy was used to sample the tracheal and bronchial mucosa in 28 horses with small airway disease. Tracheal and bronchial brushings were examined for the presence of fungi, aerobic and anaerobic bacteria, and a cytoiogical evaluation was also done on fluid collected by the bronchoalveolar lavage (BAL) technique. Microorganisms (bacteria and fungi) were isolated more often in tracheal brushings (53.6%) than in bronchial brushings (10.7%). Anaerobic bacteria were not isolated. Results of this study indicate that fiberoptic bronchoscopy using a protected catheter brush is an easy and practical technique to obtain minimally contaminated samples for isolation of microorganisms from the lower respiratory tract of horses. However, no association was observed between isolation of high numbers of microorganisms from the bronchi and severity of small airway disease.
Mostrar más [+] Menos [-]Development of surgical techniques for preparation of in vitro-isolated perfused porcine skin flaps for percutaneous absorption studies
1991
Bowman, K.F. | Monteiro-Riviere, N.A. | Riviere, J.E.
We developed a single-pedicle, axial pattern tubed skin flap that could be transferred to an in vitro perfusion apparatus. On the basis of results of prosections, angiography, contact radiography, and surviving-length studies, it was concluded that a single-pedicle, axial pattern skin flap measuring 4 cm X 12 cm incorporating the caudal superficial epigastric artery would survive to its entire length. Subsequently, a surgical (stage 1) procedure was developed for the routine preparation of single-pedicle, axial pattern tubed skin flaps. Healing after the stage-1 procedure was evaluated by visual inspection and fluorescein angiography. Stage-1 procedures were performed successfully 149 of 160 (93%) times. A second surgical (stage 2) procedure was developed for routine cannulation of the caudal superficial epigastric artery and harvest of the tubed skin flap. Stage-2 procedures were performed successfully 136 of 144 (94%) times.
Mostrar más [+] Menos [-]Thermodilution estimation of cardiac output at high flows in anesthetized horses
1991
Dunlop, C.I. | Hodgson, D.S. | Chapman, P.L. | Grandy, J.L. | Waldron, R.D.
The purpose of this study was to compare the thermodilution technique for estimation of cardiac output with the indocyanine green dye dilution technique at flows between 10 and 39 L/min in halothane-anesthetized horses. The estimation of area of dye dilution cardiac output curves was made by using the fore-'n-aft (FA) triangle method. This shorthand technique was compared with logarithmic exponential extrapolation and summation (extrapolated area), using 64 cardiac output curves. Then, 256 simultaneous thermodilution measurements were compared with dye dilution measurements calculated by use of the FA technique. Forty milliliters of iced 0.9% NaCl solution containing 15 mg of indocyanine green dye was used as the indicator. This was delivered in < 1 second to the right atrium, using a power injector. A thermistor positioned in the pulmonary artery detected the thermal indicator. Blood was withdrawn from the carotid artery through a densitometer cuvette to measure the dye concentration. The FA estimations of area were higher than those determined by use of extrapolated area. A multiplicative adjustment of 0.837 was estimated. On average, thermodilution estimates of cardiac output exceeded the adjusted FA determinations. Using a weighted linear regression, we determined the following calibration adjustment: thermal dilution cardiac output/1.048 = indocyanine green dye dilution cardiac output.