Refinar búsqueda
Resultados 1-10 de 200
In vitro evaluation of four methods of attaching transfixation pins into a fiberglass cast for use in horses.
1996
McClure S.R. | Watkins J.P. | Hogan H.A.
Estimation of glomerular filtration rate and evaluation of renal function in ferrets (Mustela putorius furo).
1994
Esteves M.I. | Marini R.P. | Ryden E.B. | Murphy J.C. | Fox J.G.
Three methods of determining glomerular filtration rate (GFR) were performed in adult ferrets, 9 months to 7 years old. Endogenous creatinine clearance was determined, using serum and urine creatinine values obtained during 24- and 48-hour collection periods from 27 ferrets housed in metabolic cages. Creatinine and radiolabeled inulin were administered to 12 female ferrets by constant IV infusion during isoflurane-induced anesthesia. Serial 20-minute urine collections, together with serum samples obtained at the midpoint of urine collection, provided measures for clearance calculations of these substances. Mean +/- SD endogenous creatinine clearance in ferrets for metabolic cage collections was 2.50 +/- 0.93 ml/min/ kg of body weight. There were no significant differences between the 24- and 48-hour clearance rates. Mean inulin clearance was 3.02 +/- 1.78, and mean exogenous creatinine clearance was 3.32 +/- 2.16 ml/ min/kg. Analysis of variance, using least-squared means adjustment, did not yield any significant differences between inulin and exogenous creatinine clearance rates. Exogenous creatinine clearance-to-inulin clearance ratio was 0.99 +/- 0.46, and there was significant correlation between the 2 methods (r = 0.82, P = 0.0001). Significant body temperature effects on inulin or exogenous creatinine clearance were not found. Infused inulin clearance, the generally preferred method for GFR calculation in mammalian species, was significantly (P = 0.0069) higher in younger (3.65 ml/min/kg) vs older ferrets (2.29 ml/min/kg). Results of this study indicate that inulin clearance is an adequate measure of GFR in ferrets as it is in other species. Compared with inulin clearance, exogenous creatinine clearance also provides a reliable estimate of GFR in ferrets.
Mostrar más [+] Menos [-]Endogenous creatinine clearance measurement of glomerular filtration rate in dogs.
1993
Finco D.R. | Tabaru H. | Brown S.A. | Barsanti J.A.
Renal clearance procedures were performed on adult mixed-breed dogs with a wide range of renal function. Endogenous creatinine clearance was computed after analyzing plasma and urine for creatinine by use of 2 methods, PAP and kinetic Jaffe. For 20-minute clearance procedures, [14C]inulin clearance was measured simultaneously with endogenous creatinine clearance. For 111 twenty-minute clearance procedures performed on 24 dogs, [14C]inulin clearance was highly correlated with creatinine clearance for both methods of creatinine analysis (R2 = 0.979 for [14C]inulin-PAP; R2 = 0.943 for [14C]inulin-Jaffe). The absolute values for PAP and [14C]inulin clearance were nearly the same (PAP-to-[14C]inulin clearance ratio = 1.03 +/- 0.08), but those for Jaffe clearance were substantially less than those for [14C] inulin clearance Jaffe-to-[14C]inulin clearance ratio = 0.88 +/- 0.10). The Jaffe-to-[14C] inulin clearance ratio was inversely correlated with degree of renal function (R2 = 0.464), whereas the PAP-to-[14C]inulin clearance ratio was not correlated with degree of renal function (R2 = 0.060). Thus, Jaffe-determined creatinine clearance varied, in relation to [14C] inulin clearance, depending on degree of renal function. In 4 clinically normal dogs, 20-minute and 24-hour sample collections analyzed by use of the PAP method gave clearance values significantly greater, for both periods, than did Jaffe analyses. The PAP-determined creatinine clearance values were less than, but not significantly different from 20-minute exogenous creatinine clearance values determined 10 days after 24-hour collections. For 20-minute and 24-hour collections, the difference in clearance values between the PAP and Jaffe methods was attributable mostly to lower plasma creatinine values for the PAP method (mean +/- SEM, plasma PAP-to-Jaffe ratio = 0.798 +/- 0.053). However, urine creatinine values also were less by use of the PAP method.
Mostrar más [+] Menos [-]Effects of abdominal insufflation with nitrous oxide on cardiorespiratory measurements in spontaneously breathing isoflurane-anesthetized dogs.
1993
Gross M.E. | Jones B.D. | Bergstresser D.R. | Rosenhauer R.R.
Cardiorespiratory effects of abdominal insufflation were evaluated in 8 dogs during isoflurane anesthesia. Each dog was studied 3 times, in 1 of the following orders of insufflation pressures: 10-20-30, 20-30-10, 30-20-10, 10-30-20, 20-10-30, and 30-10-20 mm of Hg. Anesthesia was induced by use of a mask, dogs were intubated, and anesthesia was maintained by isoflurane in 100% oxygen. After instrumentation, baseline values were recorded (time 0), and the abdomen was insufflated with nitrous oxide. Data were recorded at 5, 10, 15, 20, 25, and 30 minutes after insufflation. The abdomen was then desufflated, with recording of data continuing at 35 and 40 minutes. Mean arterial pressure increased at 5 minutes during 20 mm of Hg insufflation pressure, and from 20 to 30 minutes during 30 mm of Hg pressure. Tidal volume decreased from 5 to 30 minutes during 10 and 20 mm of Hg pressures, and from 5 to 40 minutes during 30 mm of Hg pressure. Minute ventilation decreased at 10 and 20 minutes during 20 mm of Hg pressure. End-tidal CO2 concentration increased from 5 to 30 minutes during 20 and 30 mm of Hg pressure. The PaCO2 decreased at 40 minutes during 10 mm of Hg pressure, at 30 minutes during 20 mm of Hg pressure, and from 10 to 40 minutes during 30 mm of Hg pressure. Values for pH decreased from 10 to 30 minutes during 20 and 30 mm of Hg pressures. The PaO2 decreased from 20 to 40 minutes during 10 mm of Hg pressure, at 30 minutes during 20 mm of Hg pressure, and from 10 to 40 minutes during 30 mm of Hg pressure. Percentage decrease in tidal volume was greater at 5 and 15 minutes with 30 mm of Hg pressure. Differences in percentage increase in end tidal CO2 concentration were observed among the 3 pressures from 5 to 30 minutes. Although significant, these changes do not preclude use of laparoscopy if insufflation pressure > 20 mm of Hg is avoided.
Mostrar más [+] Menos [-]Preparation and transfusion of canine platelet concentrates.
1993
Abrams Ogg A.C.G. | Kruth S.A. | Carter R.F. | Valli V.E. | Kamel Reid S. | Dube I.D.
A protocol was developed for preparation of platelet concentrates (PC) to support thrombocytopenic dogs. Four clinically normal dogs with platelet counts that ranged from 200 to 330 X 10(9) platelets/L were used as donors. One unit (450 ml) of blood was collected by venipuncture into a double blood bag. Whole blood (WB) was centrifuged for 4 minutes at 1,000 X g (braking time = 2 minutes, 30 seconds) to prepare platelet-rich plasma (PRP). The PRP was expressed into the satellite bag and was centrifuged for 10 minutes at 2,000 X g (braking time = 2 minutes, 36 seconds). The platelet-poor plasma was expressed, leaving 40 to 70 ml of plasma and the pelleted platelets in the satellite bag. The resulting PC was left undisturbed for 60 minutes to promote disaggregation, and the platelets were then resuspended by gentle manual agitation. Forty-eight PC were prepared. Mean (+/- SD) platelet yield from WB to PRP was 78 +/- 13)% (range, 35 to 97%); yield from PRP to PC was 94 (+/- 6) % (range, 75 to 100%); and overall yield (PC from WB) was 74 (+/- 13) % (range, 36 to 91%). Mean PC platelet count was 8.0 (+/- 3.0) X 10(10) platelets/PC (range, 2.3 to 13.4 X 10(10) platelets/PC). The WBC content was 0.1 to 2.3 X 10(9) platelets/PC, representing 3 to 74% of WBC in the WB. Hematocrit was 0.1 to 26.2%. Results of bacterial and fungal culturing were negative.
Mostrar más [+] Menos [-]Non-surgical embryo recovery in the water buffalo.
1988
Ocampo M.B. | Uenishi R.S. | Valdez C.A. | Pastor J. | Cruz L. | Kanagawa H.
Comparison of Some Bacterial Identification Methods
2019
Gulaydin, Ozgul | Eki̇n, Ismail Hakki | Oztürk, Cihat | Ilhan, Ziya | Ogun, Erdal
In this study, three different methods were compared for the identification of some Gram-positive and Gramnegative reference bacteria. Material and Methods: For this purpose, the identification accuracy rates of Enterococcus faecalis, Enterococcus faecium, Streptococcus agalactiae, Staphylococcus aureus, Escherichia coli, Pseudomonas aeruginosa, Salmonella typhimurium, Serratia marcescens were analysed by conventional bacteriological methods, commercial bacterial identification test kit (Microgen™ ID) and automated bacteria identification system (BD Phoenix 100™).
Mostrar más [+] Menos [-]Evaluation of delayed-image bone scintigraphy to assess bone formation after distraction osteogenesis in dogs
2006
Theyse, L.F. | Hazewinkel, H.A. | Terlou, M. | Pollak, Y.W. | Voorhout, G.
Objective-To quantitatively assess distraction-induced bone formation in a crural lengthening model in dogs by use of delayed-image bone scintigraphy. Animals-12 mature Labrador Retrievers. Procedure-Dogs were randomly allocated to 1 of 3 groups. A circular external skeletal fixation system was mounted on the right crus of each dog. Osteotomy of the distal portion of the tibia and fibula was performed in groups 1 and 2 and was followed by a lengthening procedure of 10 mm in the first group only. The third group served as sham-operated controls. Delayed-image bone scintigraphy with technetium-99m hydroxy methylene diphosphonate was performed 2, 4, and 6 weeks after surgery. Delayed-image-to-region-of-interest, delayed-image-to-crural, and delayed-image-to-femoral scintigraphic activity ratios were calculated. New bone formation was quantified by use of densitometric image analysis, and values for the scintigraphic ratios were compared. Results-In the distraction and osteotomy groups, delayed-image-to-region-of-interest and delayed-image-to-crural ratios increased significantly. Although densitometric image analysis revealed increased bone formation after distraction, the region-of-interest ratios and crural ratios were similar in both groups. All dogs had increased delayed-image-to-femoral ratios. Conclusions and Clinical Relevance-Delayed-image bone scintigraphy ratios were not effective at differentiating between the amounts of distraction-induced bone and osteotomy-induced bone. Metabolic bone activity in the adjacent femur was increased as a consequence of circular external skeletal fixator placement. Delayed-image bone scintigraphy was not adequately sensitive to quantitatively monitor bone formation but may be useful as an early predictor of bone healing.
Mostrar más [+] Menos [-]Evaluation of isoflurane and sevoflurane vaporizers over a wide range of oxygen flow rates
2006
Ambrisko, T.D. | Klide, A.M.
Objective-To examine the accuracy and precision of isoflurane and sevoflurane anesthetic vaporizers. Sample Population-5 identcal isoflurane and 5 identical sevoflurane vaporizers. Procedures-Oxygen flow rates from 0.02 to 10 L/min were used with different vaporizer dial settings. Agent concentrations were measured at the common gas outlet by use of a refractometer. Accuracy was defined as the difference between measured agent concentrations, and dial settings were expressed as a percentage of the applied dial settings. Precision was defined as SD of the measured agent concentrations for each combination of dial setting and flow. Results-Isoflurane values were generally greater than the dial settings. Accuracy of the isoflurane vaporizer was > 20% when 0.6% and 1% was dialed. Accuracy of the sevoflurane vaporizer was always within +/- 20% but decreased at 0.02 L/min flow and at combinations of high flow and high dial settings. Overall precision of the isoflurane vaporizer was better than that of the sevoflurane vaporizer. Conclusions and Clinical Relevance-A possible explanation for the inaccuracy of the isoflurane vaporizer may be that it was manufactured to be accurate with air but not oxygen, which must be accounted for when using the vaporizer with oxygen, especially with nonrebreathing systems. The sevoflurane vaporizer may not deliver accurate agent concentrations at high flow and high dial settings. Both vaporizers are suitable for clinical use with a wide range of oxygen flow rates if these precautions are properly addressed.
Mostrar más [+] Menos [-]Pharmacokinetics of intravenously administered caffeine in healthy alpacas (Lama pacos) and llamas (Lama glama)
2006
Lakritz, J. | Middleton, J.R. | Anderson, D.E. | Linden, D.R. | Sams, R.A. | Tessman, R.K. | Tyler, J.W.
Objective-To determine the pharmacokinetic disposition of IV administered caffeine in healthy Lama spp camelids. Animals-4 adult male alpacas and 4 adult female llamas. Procedures-Caffeine (3 mg/kg) was administered as an IV bolus. Plasma caffeine concentrations were determined by use of high-performance liquid chromatography in 6 animals and by use of liquid chromatography-mass spectrometry in 2 llamas. Results-Median elimination half-life was 11 hours (range, 9.3 to 29.8 hours) in alpacas and 16 hours (range, 5.4 to 17 hours) in llamas. The volume of distribution at steady state was 0.60 L/kg (range, 0.45 to 0.93 L/kg) in alpacas and 0.75 L/kg (range, 0.68 to 1.15 L/kg) in llamas. Total plasma clearance was 44 mL/h/kg (range, 24 to 56 mL/h/kg) in alpacas and 42 mL/h/kg (range, 30 to 109 mL/h/kg) in llamas. Conclusions and Clinical Relevance-High-performance liquid chromatography and liquid chromatography-mass spectrometry were suitable methods for determination of plasma caffeine concentrations in alpacas and llamas. Plasma caffeine concentration-time curves were best described by a 2-compartment model. Elimination half-lives, plasma clearance, volume of distribution at steady state, and mean residence time were not significantly different between alpacas and llamas. Intravenous administration of caffeine at a dose of 3 mg/kg did not induce clinical signs of excitement.
Mostrar más [+] Menos [-]