Refinar búsqueda
Resultados 1-3 de 3
Assessment of the effects of dalteparin on coagulation variables and determination of a treatment schedule for use in cats
2016
Schonig, Jette C. | Mischke, Reinhard H.
OBJECTIVE To determine a treatment protocol for SC administration of dalteparin to cats on the basis of currently available detailed pharmacokinetic data and to assess the effect of SC administration of dalteparin to cats on coagulation variables such as activated partial thromboplastin time (aPTT), thrombin time, and results for thromboelastometry, compared with effects on anti–activated coagulation factor X (anti-Xa) activity. ANIMALS 6 healthy domestic shorthair cats. PROCEDURES Cats received 14 injections of dalteparin (75 anti-Xa U/kg, SC) at 6-hour intervals. Blood samples were collected before and 2 hours after the first and second injections on days 1, 2, and 4. Anti-Xa activity was measured by use of a chromogenic substrate assay, aPTT and thrombin time were measured by use of an automated coagulometer, and viscoelastic measurements were obtained with thromboelastrometry. RESULTS 2 hours after the second injection, the target peak anti-Xa activity range of 0.5 to 1.0 U/mL was achieved in all cats, whereas median trough values remained below this range. Peak anti-Xa activity had only minimal effects on coagulation variables; the maximum median ratio for aPTT (in relationship to the value before the first dalteparin injection) was 1.23. CONCLUSIONS AND CLINICAL RELEVANCE Results of this study indicated that this treatment protocol resulted in reproducible anti-Xa activity in cats that was mostly within the targeted peak range of anti-Xa activity recommended for humans. Treatment in accordance with this protocol may not require routine coagulation monitoring of cats, but this must be confirmed in feline patients.
Mostrar más [+] Menos [-]Adherence of methicillin-resistant Staphylococcus pseudintermedius to suture materials commonly used in small animal surgery
2016
Morrison, Shauna | Singh, Ameet | Rousseau, Joyce | Weese, J Scott
OBJECTIVE To evaluate adherence of methicillin-resistant Staphylococcus pseudintermedius (MRSP) to 5 suture materials commonly used in small animal surgery. SAMPLE 10 epidemiologically unrelated MRSP isolates (obtained from dogs with clinical infections) that had strong biofilm-forming ability and 5 types of suture. PROCEDURES The 5 types of suture evaluated were monofilament polyglecaprone 25, monofilament polydioxanone, triclosan-coated (TC)–monofilament polydioxanone, braided polyglactin 910, and barbed monofilament polydioxanone. Suture segments were incubated in standard suspensions of MRSP for 2 minutes. Segments were then placed in tryptone soy broth and incubated overnight. After incubation, segments were rinsed with PBS solution and sonicated to dislodge adherent bacteria. Resulting suspensions were used to create serial dilutions that were plated, incubated overnight, and counted the following day. Bacterial adherence to 1 segment of each suture type was assessed by use of scanning electron microscopy. RESULTS There was significantly less adherence of MSRP to TC–monofilament polydioxanone than to polyglecaprone 25, polyglactin 910, barbed monofilament polydioxanone, and monofilament polydioxanone. There was significantly less adherence of MSRP to polyglecaprone than to polyglactin 910. CONCLUSIONS AND CLINICAL RELEVANCE Barbed suture had a bacterial adherence profile comparable to that for monofilament suture. Adherence of MRSP was greatest for braided polyglactin 910. Use of TC–monofilament polydioxanone can be considered for patients that are at high risk of developing surgical site infections and for which a surgeon chooses a multifilament suture.
Mostrar más [+] Menos [-]Diagnostic accuracy of a rapid immunoassay for point of-care detection of urinary tract infection in dogs
2016
Jacob, Megan E. | Crowell, Denise | Fauls, Megan B. | Griffith, Emily H. | Ferris, Kelli K.
OBJECTIVE To determine the diagnostic accuracy of a rapid immunoassay (RIA) for point-of-care detection of urinary tract infection (UTI) of dogs, compared with criterion-referenced diagnosis with bacterial culture. SAMPLE 200 urine samples obtained from dogs and submitted to a veterinary microbiology diagnostic laboratory for routine bacterial culture and antimicrobial susceptibility determination. PROCEDURES Samples were evaluated by use of quantitative bacterial culture and the RIA. Sensitivity, specificity, and positive and negative predictive values of the RIA were calculated; results of bacterial culture were the criterion-referenced outcome. A κ statistic was calculated to determine agreement between bacterial culture and RIA results. RESULTS 56 of 200 (28%) urine samples had positive results for bacterial growth by use of culture methods; there were 38 (19%) positive results likely to be associated with bacterial UTI on the basis of sample collection method and bacterial concentration. Sensitivity and specificity of the RIA for detecting samples likely to be associated with UTI (≥ 1,000 CFUs/mL) were 97.4% and 98.8%, respectively. The positive and negative predictive values of the RIA for bacterial cultures with likely UTI were 0.949 and 0.994, respectively. Agreement between bacterial culture and RIA outcome for UTI was substantial (weighted κ, 0.718). CONCLUSIONS AND CLINICAL RELEVANCE The RIA test evaluated in this study accurately detected UTI of dogs, compared with detection with the criterion-referenced bacterial culture method. Use of this point-of-care RIA could allow clinicians to diagnose UTI at the time of a patient visit and provide information useful for immediately initiating empirical antimicrobial treatment.
Mostrar más [+] Menos [-]