Refinar búsqueda
Resultados 1-10 de 80
Transcutaneous oxygen monitoring for predicting skin viability in dogs
1993
Rochat, M.C. | Pope, E.R. | Payne, J.T. | Pace, L.W. | Wagner-Mann, C.C.
Transcutaneous oxygen (PO2.TC) monitoring is commonly used in human medicine for evaluating skin viability. The application of transcutaneous monitoring for evaluating skin viability in dogs was investigated. The changes in PO2-TC values were measured from 16 avascular skin flaps created along the lateral hemithoraces of 4 dogs. Transcutaneous oxygen values were serially recorded from the vascular base and avascular apex of each flap for 12 hours after surgery. A single transcutaneous measurement was obtained from each flap base and apex 24 hours after surgery. Serial arterial blood gas analyses were obtained to compare central oxygen values with PO2-TC values. Full-thickness skin biopsy specimens were harvested from the base and apex of each flap 24 hours after surgery. The flaps were observed for 4 days and then excised for histologic examination. A subjective grading scale was used to assess histologic changes. Throughout the 12-hour period and at 24 hours, a statistically significant difference was found between the PO2-TC values for apices and bases of the flaps. The mean PO2-TC for all bases was 90.9 mm of Hg +/- 3.3 SEM, and the mean PO2-TC for all apices was 21.2 mm of Hg +/- 1.8 SEM. The mean regional perfusion index (apex PO2.TC/base PO2-TC) was 0.23 +/- 0.02. The subjective numbers assigned to the biopsy specimens were statistically evaluated by using a paired Student's t test and a Wilcoxon signed-rank test. A significant difference was found between the numbers for the collective bases and apices with both tests. A statistically significant difference was found between the numbers for the apex biopsy specimens taken 24 hours after creation of the skin flap and those taken when the flap was excised, whereas no difference was found between the numbers for the base biopsy specimens. On the basis of our findings, PO2-TC monitoring is a useful technique for assessing skin viability in dogs.
Mostrar más [+] Menos [-]Tracheal mucociliary transport rate in awake dogs
1993
Boothe, H.W. | Boothe, D.M. | Komkov, A. | Longnecker, M.T. | Hightower, D.
To measure tracheal mucociliary transport rate (TMTR) in awake dogs, restrained in dorsal recumbency, 99mtechnetium-labeled macroaggregated albumin was administered by tracheal injection, and the cephalic movement of boluses containing the radiopharmaceutical was detected by a gamma camera positioned lateral to the dog's head and neck. The distance traveled by each bolus was measured, relative to external markers placed a known distance apart. Tracheal mucociliary transport rates were calculated by dividing the measured distance of radiopharmaceutical movement by elapsed time. The technique was efficient and well tolerated. Mean (+/- SD) TMTR was 35.3 +/- 15.9 mm/min. Significant (P = 0.029) difference in TMTR was found between males and females, but significant difference attributable to age of the dog was not detected. This method of measuring TMTR in awake dogs has potential for evaluation of clinical animal patients with suspected tracheal mucociliary abnormalities.
Mostrar más [+] Menos [-]Lactulose and mannitol as probe markers for in vivo assessment of passive intestinal permeability in healthy cats
1993
Papasouliotis, K. | Gruffydd-Jones, T.J. | Sparkes, A.H. | Cripps, P.J. | Millard, W.G.
Intestinal permeability was assessed in 12 healthy cats by use of a differential sugar absorption test. A 50-ml isotonic aqueous solution containing a combination of 1.8 g of the disaccharide lactulose and 1.7 g of the monosaccharide mannitol was administered to cats via nasogastric tube. Urine was collected after 6 hours, and all urine samples were analyzed the same day, using a gas-liquid chromatographic technique (GLC) and an enzymatic assay (ENZ). Median urinary recovery of lactulose was 0.27 and 0.54% determined by GLC and ENZ, respectively. Differences between these groups were statistically significant (P = 0.023), and correlation between assays was high (r = 0.94, P < 0.01). Median urinary recovery of mannitol was 1.93 and 2.09% for GLC and ENZ, respectively. There were no statistically significant differences between these groups and the correlation between assays was high (r = 0.85, P < 0.01). The median lactulose-to-mannitol ratio was 0.29, using GLC, and was 0.52, using ENZ. Correlation of these ratios was again high (r = 0.93, P < 0.01).
Mostrar más [+] Menos [-]Reproducibility of urethral pressure profiles in clinically normal sexually intact female dogs by use of microtransducer catheters
1993
Arnold, S. | Chew, D.J. | Hubler, M. | Casal, M. | Wiestner, T. | Hogg, H. | Heckmann, R. | Powers, J. | Ruesch, P.
Urethral pressures profiles (UPP) obtained by use of microtransducer catheters were determined in 8 anestrous sexually intact female Beagles during general anesthesia. A UPP study consisted of 3 consecutive recordings, and 4 UPP studies were repeated at an interval of 5 days in each dog. Maximal urethral pressure (cm of H2O), bladder pressure (cm of H2O), and anatomic urethral length (cm) were recorded. Maximal urethral closure pressure (cm of H2O) was calculated. Mean +/- SD (for all measurements) maximal urethral closure pressure was 12.8 +/- 5.6 cm of H2O (range, 2.4 to 25.2 cm of H2O). Maximal urethral closure pressure was significantly (P < 0.05) decreased during the first recording period (11.4 +/- 5.8 cm of H2O), Compared with the second (13.0 +/- 5.2 cm of H2O) or third 14.1 +/- 5.7 cm of H2O) recording periods within a UPP study (3 consecutive recordings). Mean maximal difference in urethral closure pressure during a single UPP study was 4.8 +/- 2.4 cm of H2O. Significant difference in maximal urethral closure pressure was not observed between studies. Mean (for all measurements) anatomic urethral length was 6.2 +/- 0.9 cm (4.1 to 7.8 cm). Anatomic urethral length was significantly (P < 0.05) less during the first recording period (6.1 +/- 0.9 cm), compared with values for the second and third periods (6.3 +/- 0.9 cm, 6.4 0.9 cm respectively). Anatomic urethral length for time 3 was significantly (P < 0.05) less than the value for time 1 (5.8 +/- 0.7 cm vs 6.6 +/- 0.8 cm). We conclude that the microtransducer catheter technique for measurement of UPP was reproducible during a single study and between successive studies. This method is useful in documenting maximal urethral pressure, maximal urethral closure pressure, and anatomic urethral length in clinically normal sexually intact female dogs.
Mostrar más [+] Menos [-]Ultrasonographically detected changes in equine superficial digital flexor tendons during the first months of race training
1993
Gillis, C.L. | Meagher, D.M. | Pool, R.R. | Stover, S.M. | Craychee, T.J. | Willits, N.
The forelimb superficial digital flexor (SDF) tendons of 6 Thoroughbreds were examined clinically and ultrasonographically during the first 4 months of race training. Sonograms were interpreted clinically and by use of computer-aided analysis. Tendon tissue from all horses was examined histologically at the end of the study. Computer-aided analysis of sonograms of the SDF tendons revealed trends toward an increase in mean cross-sectional area and a decrease in mean echogenicity over time with training. An inverse relation was found between increase in cross-sectional area and decrease in mean echogenicity over time in training. Two of the trained horses developed clinical signs of mild SDF tendonitis. Ultrasonography revealed an increase in cross-sectional area and decrease in mean echogenicity of clinically affected areas of the SDF tendons of 1 horse, compared with changes observed prior to the onset of tendonitis (these changes were not statistically significant). Blood vessels and lymphatics supplying the clinically and ultrasonographically affected tendon sites were large and thick-walled. These changes were not observed in the tendons of the other horses at the end of the study. The authors conclude that equine SDF tendons adapt to the early months of race training by increasing in size and decreasing in echogencity, as determined by ultrasonography.
Mostrar más [+] Menos [-]Effects of abdominal insufflation with nitrous oxide on cardiorespiratory measurements in spontaneously breathing isoflurane-anesthetized dogs
1993
Gross, M.E. | Jones, B.D. | Bergstresser, D.R. | Rosenhauer, R.R.
Cardiorespiratory effects of abdominal insufflation were evaluated in 8 dogs during isoflurane anesthesia. Each dog was studied 3 times, in 1 of the following orders of insufflation pressures: 10-20-30, 20-30-10, 30-20-10, 10-30-20, 20-10-30, and 30-10-20 mm of Hg. Anesthesia was induced by use of a mask, dogs were intubated, and anesthesia was maintained by isoflurane in 100% oxygen. After instrumentation, baseline values were recorded (time 0), and the abdomen was insufflated with nitrous oxide. Data were recorded at 5, 10, 15, 20, 25, and 30 minutes after insufflation. The abdomen was then desufflated, with recording of data continuing at 35 and 40 minutes. Mean arterial pressure increased at 5 minutes during 20 mm of Hg insufflation pressure, and from 20 to 30 minutes during 30 mm of Hg pressure. Tidal volume decreased from 5 to 30 minutes during 10 and 20 mm of Hg pressures, and from 5 to 40 minutes during 30 mm of Hg pressure. Minute ventilation decreased at 10 and 20 minutes during 20 mm of Hg pressure. End-tidal CO2 concentration increased from 5 to 30 minutes during 20 and 30 mm of Hg pressure. The PaCO2 decreased at 40 minutes during 10 mm of Hg pressure, at 30 minutes during 20 mm of Hg pressure, and from 10 to 40 minutes during 30 mm of Hg pressure. Values for pH decreased from 10 to 30 minutes during 20 and 30 mm of Hg pressures. The PaO2 decreased from 20 to 40 minutes during 10 mm of Hg pressure, at 30 minutes during 20 mm of Hg pressure, and from 10 to 40 minutes during 30 mm of Hg pressure. Percentage decrease in tidal volume was greater at 5 and 15 minutes with 30 mm of Hg pressure. Differences in percentage increase in end tidal CO2 concentration were observed among the 3 pressures from 5 to 30 minutes. Although significant, these changes do not preclude use of laparoscopy if insufflation pressure > 20 mm of Hg is avoided.
Mostrar más [+] Menos [-]Recovery of horses from inhalation anesthesia
1993
Whitehair, K.J. | Steffey, E.P. | Willitis, N.H. | Woliner, M.J.
To study behavioral and cardiopulmonary characteristics of horses recovering from inhalation anesthesia, 6 nonmedicated horses were anesthetized under laboratory conditions on 3 different days, with either halothane or isoflurane in O2. Anesthesia was maintained at constant dose (1.5 times the minimum alveolar concentration [MAC]) of halothane in O2 for 1 hour (H1), halothane in O2 for 3 hours (H3), or isoflurane in O2 for 3 hours (13). The order of exposure was set up as a pair of Latin squares to account for horse and trial effects. Circulatory (arterial blood pressure and heart rate) and respiratory (frequency, PaCO2, PaO, pHa) variables were monitored during anesthesia and for as long as possible during the recovery period. End-tidal percentage of the inhaled agent was measured every 15 seconds by automated mass spectrometry, then by hand-sampling after horses started moving. Times of recovery events, including movement of the eyelids, ears, head, and limbs, head lift, chewing, swallowing, first sternal posture and stand attempts, and the number of sternal posture and stand attempts, were recorded. The washout curve or the ET ratio (end-tidal percentage of the inhaled agent at time t to end-tidal percentage of the inhaled agent at the time the anesthesia circuit was disconnected from the tracheal tube) plotted against time was similar for HI and H3. The slower, then faster (compared with halothane groups) washout curve of isoflurane was explainable by changes in respiratory frequency as horses awakened and by lower blood/gas solubility of isoflurane. The respiratory depressant effects of isoflurane were marked and were more progressive than those for halothane at the same 1.5 MAC dose. During the first 15 minutes of recovery, respiratory frequency for group-13 horses increased significantly (P < 0.05), compared with that for the halothane groups. For all groups, arterial blood pressure increased throughout the early recovery period and heart rate remained constant. Preanesthesia temperament of horses and the inhalation agent used did not influence the time of the early recovery events (movement of eyelids, ears, head, and limbs), except for head lift. For events that occurred at anesthetic end-tidal percentage < 0.20, or when horses were awake, temperament was the only factor that significantly influenced the nature of the recovery (chewing P = 0.04, extubation P = 0.001, first stand attempt P = 0.008, and standing P = 0.005). The quality of the recoveries did not differ significantly among groups (H1, H3, I3) or horses; however 5 of 6 horses recovering from the H1 exposure had ideal recovery. During recovery, the anesthetic end-tidal percentage did not differ significantly among groups. However, when concentrations were compared on the basis of anesthetic potency (ie, MAC multiple) a significantly (P < 0.05) lower MAC multiple of isoflurane was measured for the events ear movement, limb movement, head lift, and first attempt to sternal posture, compared with that for horses given halothane, indicating that isoflurane may be a more-potent sedative than halothane in these horses.
Mostrar más [+] Menos [-]Comparative effects of xylazine and propofol on the urethral pressure profile of healthy dogs
1993
Combrisson, H. | Robain, G. | Cotard, J.P.
The effects of 2 drugs, xylazine and propofol, on the urethral pressure profile were compared. Seven female dogs were sedated by administration of one drug, then the other, and urethral variables were measured. In the dogs sedated with propofol, the mean +/- SD, maximal urethral closure pressure (51 +/- 7.4 cm of H2O) was significantly (P < 0.05) higher than the value when dogs were sedated with xylazine (23.3 +/- 7.6 cm of H2O). Results were compared with those obtained by various authors, in particular for nonsedated dogs. It is concluded that propofol is a good drug for investigation of the urethral pressure profile, whatever its effect on maximal urethral closure pressure.
Mostrar más [+] Menos [-]Differential study of electrocardiographic intervals in two neonatal crossbred swine
1993
Rubio, M.D. | Tovar, P. | Santisteban, R. | Oliveira, M. de | Castejon, F.
The influence of the QT, TQ, and ST intervals, and heart score on both cardiac cycle duration (RR) and diastole/systole (D/S) quotient were analyzed during the neonatal (1 day and 5 days) pigs belonging to 2 crossbreeds of different rusticity, Landrace X Belgian White (LBW) and Landrace X Duroc Jersey (LDJ). Our findings indicate that the shortening of the RR interval in 5-day-old pigs of both crossbreeds was determined by different variables in each breed. In LDJ pigs, this shortening was only associated with a shortening of ventricular activation, and in each age group, the systole and the diastole contributed equally to the RR value. The D/S quotient did not differ significantly in 1-day-old vs 5-day-old pigs, and at both ages, the quotient was only determined by the TQ value. In LBW pigs, the RR, QT, TQ, and ST were shortened, but only the shortening of QT was significant as a result of an acceleration of the ventricular recuperation process. Moreover, differences were found between 1-day-old vs 5-day-old pigs with regard to the contribution of the different intervals to the RR duration. In 1-day-old pigs, the RR depended closely on the TQ, whereas in 5-day-old pigs, all intervals contributed significantly to its duration. The D/S quotient was not significantly different in 1-day-old vs 5-day-old pigs, but a different contribution of the variables studied was observed at the 2 ages selected. In 1-day-old pigs, D/S quotient depended on the diastole duration, whereas in 5-day-old pigs, the diastole and systole contributed to its variation.
Mostrar más [+] Menos [-]Relation between reduced glutathione content and Heinz body formation in sheep erythrocytes
1993
Goto, I. | Agar, N.S. | Maede, Y.
To clarify the oxidant defense functions of reduced glutathione (GSH) in erythrocytes, the effect of GSH deficiency on in vitro oxidant defense was studied, using GSH-deficient sheep erythrocytes (low-GSH cells). The formation of Heinz bodies in low-GSH cells was higher than that in high-GSH cells when the cells were incubated with an oxidant drug, acetyl-phenylhydrazine (APH). Artificial depletion of GSH by 1-chloro-2,4-dinitrobenzene in high-GSH cells resulted in increased Heinz body formation in these cells incubated with APH. Furthermore, high negative correlation was observed between Heinz body formation and GSH content in sheep erythrocytes exposed to APH. These results clearly indicate that erythrocyte GSH is indispensable for erythrocyte defense against oxidative damage induced by APH, and support the previous observations that sheep with low-GSH erythrocytes were more susceptible to oxidative agents than were sheep with high-GSH erythrocytes.
Mostrar más [+] Menos [-]