Refinar búsqueda
Resultados 1-6 de 6
In vitro mechanical evaluation of equine laryngeal tie-forward constructs prepared with different suture materials and placement patterns
2015
Santos, Marcos P. | Gutierrez-Nibeyro, Santiago D. | Horn, Gavin P. | Hicke, Joshua D. | Stewart, Matthew C. | Schaeffer, David J.
OBJECTIVE To compare the mechanical properties of laryngeal tie-forward (LTF) constructs prepared with different suture materials and suture placement patterns during single load to failure testing. SAMPLE Larynges harvested from 50 horse cadavers and 5 intact horse cadavers. PROCEDURES In vitro LTF constructs were created by a standard technique with polyester sutures, a standard technique with polyethylene sutures, a modified technique with metallic implants and polyester sutures, a modified technique with metallic implants and polyethylene sutures, or a modified tie-off technique with polyester sutures (10 of each type of construct). Mechanical properties including maximal load (N) at failure and failure mode were compared among constructs. Also, maximal loads at failure of the in vitro LTF constructs were compared with the loads exerted on the sutures tightened to achieve rostral laryngeal advancement in intact cadavers. RESULTS Constructs prepared by a standard technique with polyethylene sutures had a significantly higher pull out strength than those prepared by a modified technique with metallic implants and either polyester or polyethylene sutures. For constructs prepared by a standard technique with polyethylene sutures or similarly placed polyester sutures, maximal load at failure did not differ but the failure mode did differ significantly. The load to failure for all in vitro constructs was higher than the maximal load measured during a range of motion test in intact horse cadavers. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that LTF procedures can be performed in live horses with any of the suture materials and techniques tested.
Mostrar más [+] Menos [-]Mechanical properties of various suture materials and placement patterns tested with surrogate in vitro model constructs simulating laryngeal advancement tie-forward procedures in horses
2014
Santos, Marcos P. | Gutierrez-Nibeyro, Santiago D. | Horn, Gavin P. | Johnson, Amy J. | Stewart, Matthew C. | Schaeffer, David J.
Objective- To compare the mechanical properties of laryngeal tie-forward (LTF) surrogate constructs prepared with steel fixtures and No. 5 braided polyester or braided polyethylene by use of a standard or a modified suture placement technique. Sample- 32 LTF surrogate constructs. Procedures- Surrogate constructs were prepared with steel fixtures and sutures (polyester or polyethylene) by use of a standard or modified suture placement technique. Constructs underwent single-load-to-failure testing. Maximal load at failure, elongation at failure, stiffness, and suture breakage sites were compared among constructs prepared with polyester sutures by means of the standard (n = 10) or modified (10) technique and those prepared with polyethylene sutures with the standard (6) or modified (6) technique. Results- Polyethylene suture constructs had higher stiffness, higher load at failure, and lower elongation at failure than did polyester suture constructs. Constructs prepared with the modified technique had higher load at failure than did those prepared with the standard technique for both suture materials. All sutures broke at the knot in constructs prepared with the standard technique. Sutures broke at a location away from the knot in 13 of 16 constructs prepared with the modified technique (3 such constructs with polyethylene sutures broke at the knot). Conclusions and Clinical Relevance- Results suggested LTF surrogate constructs prepared with polyethylene sutures or the modified technique were stronger than those prepared with polyester sutures or the standard technique.
Mostrar más [+] Menos [-]Method to create and maintain the patency of the bovine mammary papilla
1988
Nassef, M.T. | Coy, C.H. | Watson, G.L.
The patency of mammary papillae was reestablished after surgically induced injury. Perforated prosthetic tubes with affixed Dacron tubing or Teflon strips were implanted in 18 abrabed papillae of lactating dairy cows and were secured with sutures. Wound healing was assessed by palpation and visual inspection. All wounds, with one exception, healed by first intention. Machine milking, reinstituted on day 5 after surgery, caused no apparent discomfort. Grossly and histopathologically, all implants stimulated a variable degree of mucosal metaplasia and hyperplasia. Only implants with Teflon strips became anchored by fibrotic invasion. Mastitis, tube migration, and milk fistulas were complications of the procedure.
Mostrar más [+] Menos [-]Effects of various diets on gastric tone in the proximal portion of the stomach of horses
2002
Lorenzo-Figueras, Mireia | Jones, Galin | Merritt, Alfred M.
Objective-To assess gastric tone in the proximal portion of the stomach in horses during and after ingestion of 4 diets (2 diets of grain and 2 diets of hay). Animals-6 adult horses. Procedure-A polyester bag with a volume of approximately 1,600 ml was inserted through a gastric cannula into the proximal portion of the stomach of each horse. Internal pressure of the bag was maintained at 2 mm Hg by use of an electronic barostat, and changes in bag volume were recorded before, during, and after horses consumed diets of grain or hay. Each horse was fed 0.5 and 1.0 g of grain/kg and 0.5 and 1.0 g of hay/kg. Changes in bag volume measured by use of the barostat were indirectly related to changes in tone of the gastric wall. Results-Food intake caused a distinctly significant biphasic increase in volume. The first phase was during active ingestion, which was followed shortly by a second, more prolonged postprandial phase. The ingestion-related phase of the response to intake of a diet of 1 g of hay/kg was significantly greater than that for the other diets. Conclusion and Clinical Relevance-Ingestion of a solid meal induces a biphasic relaxation response in the proximal portion of the stomach of horses. Magnitude of the ingestion-related phase may be determined by size of the meal.
Mostrar más [+] Menos [-]Effects of exercise on gastric volume and pH in the proximal portion of the stomach of horses
2002
Lorenzo-Figueras, Mireia | Merritt, Alfred M.
Objective-To assess effects of exercise on a treadmill with changes in gastric volume and pH in the proximal portion of the stomach of horses. Animals-3 healthy adult horses. Procedure-A polyester bag of approximately 1,600 mL was placed into the proximal portion of the stomach of each horse via a nasogastric tube. Changes in bag volume, determined by an electronic barostat, were recorded before, during, and after a training session on a treadmill with and without prior withholding of food. In separate experiments, pH in the proximal portion of the stomach was continuously recorded during exercise for fed and food-withheld conditions. Finally, changes in intra-abdominal and intragastric pressure were simultaneously recorded during a training session. Results-Bag volume rapidly decreased to nearly zero during trotting and galloping. Conversely, a return to walking resulted in a sharp increase in volume and a return to pre-exercise values. Intragastric and intraabdominal pressures increased almost in parallel with walking, trotting, galloping, and galloping on a slope. Gastric pH decreased rapidly to < 4 at the beginning of walking, continued to decrease during trotting and galloping, and remained low until a return to walking. Conclusions and Clinical Relevance-Increased intra-abdominal pressure during intense exercise in horses causes gastric compression, pushing acidic contents into the proximal, squamous-lined region of the stomach. Increased duration of acid exposure directly related to daily duration of exercise may be the reason that squamous lesions tend to develop or worsen when horses are in intensive training programs.
Mostrar más [+] Menos [-]Effects of age and prosthesis material on in vitro cartilage retention of laryngoplasty prostheses in horses
1990
Dean, P.W. | Nelson, J.K. | Schumacher, J.
Cartilage retention strengths of laryngoplasty prostheses were compared in larynges of 2-, 3-, and 4-year-old horses, using doubled polyester and expanded polytetrafluoroethylene prostheses. Bilateral laryngoplasties were performed on each of 15 (seven 2-year-old, two 3-year-old, and six 4-year-old) larynges, which were collected at an abbatoir. Prostheses were secured to a mechanical testing machine, and tension causing arytenoid cartilage abduction was applied, until total failure of the cartilage or prosthesis resulted. Tension caused cricoid cartilage failure in 1 specimen, and muscular process cartilage failure in the remainder. There was no significant effect of age, prosthetic material, or side of prosthesis placement on cartilage retention of the prostheses. Additionally, frequency of multiple load-displacement peaks, indicating partial muscular process failure, was not affected by age or prosthetic material variables.
Mostrar más [+] Menos [-]