Refinar búsqueda
Resultados 1-10 de 16
Efficacy of prosthetic laryngoplasty with and without bilateral ventriculocordectomy as treatments for laryngeal hemiplegia in horses.
1996
Tetens J. | Derksen F.J. | Stick J.A. | Lloyd J.W. | Robinson N.E.
Therapeutic effects of revascularisation on the healing of free bone grafts in dogs
2020
Zheng, Jia-San | Ruan, Hong-Ri | Shuang-Qiu, | Jing-Nie, | Hou, Kai-Wen | Rui-Wu,
The therapeutic effect of subcutaneous embedding and revascularisation on the repair of canine bone defects caused by open fracture was examined. A total of 12 adult beagle dogs were randomly split into a control group (group C) and a test group (group T). A section of the radius was removed from each dog under general anaesthesia and the deficit supported by an orthopaedic implant. Group T had the section surgically implanted next to the blood vessel–rich saphenous vein and Group C had it cryopreserved at −80°C. After eight weeks, the bone was surgically implanted back into the matching radial deficit. Bone healing was evaluated by gross morphological and X-ray examinations, post-mortem histology, and successive blood measurements of key bone biochemical markers. At 12 weeks, the bone healing boundary was disappearing more quickly in group T dogs than in their group C counterparts. X-ray and histological examinations showed that the cortical repair of group T subjects was complete and the bony plate arrangement was more regular than that in group C. The levels of bone biochemical markers also proved that the healing state of group T was better. The results showed that the degree of healing, osteoclast activity, and bone formation status of group T were better than those of group C, proving that the vascularised bone graft had a significantly shorter healing time than the cryopreserved bone graft.
Mostrar más [+] Menos [-]Ex vivo modeling of the airflow dynamics and two-and three-dimensional biomechanical effects of suture placements for prosthetic laryngoplasty in horse
2020
Lynch, Nicola P. | Jones, Sarah A. | Bazley-White, Lucy G. | Wilson, Zoe F. | Raffetto, Jennifer | Pfau, Thilo | Cheetham, Jonathon | Perkins, Justin D.
OBJECTIVE To identify the degree of left arytenoid cartilage (LAC) abduction that allows laryngeal airflow similar to that in galloping horses, assess 2-D and 3-D biomechanical effects of prosthetic laryngoplasty on LAC movement and airflow, and determine the influence of suture position through the muscular process of the arytenoid cartilage (MPA) on these variables. SAMPLE 7 equine cadaver larynges. PROCEDURES With the right arytenoid cartilage maximally abducted and inspiratory airflow simulated by vacuum, laryngeal airflow and translaryngeal pressure and impedance were measured at 12 incremental LAC abduction forces (0% to 100% [maximum abduction]) applied through laryngoplasty sutures passed caudocranially or mediolaterally through the left MPA. Cross-sectional area of the rima glottis and left-to-right angle quotient were determined from photographs at each abduction force; CT images were obtained at alternate forces. Arytenoid and cricoid cartilage markers allowed calculation of LAC roll, pitch, and yaw through use of Euler angles on 3-D reconstructed CT images. RESULTS Translaryngeal pressure and impedance decreased, and airflow increased rapidly at low abduction forces, then slowed until a plateau was reached at approximately 50% of maximum abduction force. The greatest LAC motion was rocking (pitch). Suture position through the left MPA did not significantly affect airflow data. Approximately 50% of maximum abduction force, corresponding to a left arytenoid angle of approximately 30° and left-to-right angle quotient of 0.79 to 0.84, allowed airflow of approximately 61 ± 6.5 L/s. CONCLUSIONS AND CLINICAL RELEVANCE Ex vivo modeling results suggested little benefit to LAC abduction forces > 50%, which allowed airflow similar to that reported elsewhere for galloping horses.
Mostrar más [+] Menos [-]Effects of tibial plateau angle and spacer thickness applied during in vitro canine total knee replacement on three-dimensional kinematics and collateral ligament strain
2014
Baker, Katherine M. | Foutz, Timothy L. | Johnsen, Kyle J. | Budsberg, Steven C.
Objective—To quantify the 3-D kinematics and collateral ligament strain of stifle joints in cadaveric canine limbs before and after cranial cruciate ligament transection followed by total knee replacement (TKR) involving various tibial plateau angles and spacer thicknesses. Sample—6 hemi-pelvises collected from clinically normal nonchondrodystrophic dogs (weight range, 25 to 35 kg). Procedures—Hemi-pelvises were mounted on a modified Oxford knee rig that allowed 6 degrees of freedom of the stifle joint but prevented mechanical movement of the hip and tarsal joints. Kinematics and collateral ligament strain were measured continuously while stifle joints were flexed. Data were again collected after cranial cruciate ligament transection and TKR with combinations of 3 plateau angles (0°, 4°, and 8°) and spacer thicknesses (5, 7, and 9 mm). Results—Presurgical (ie, normal) stifle joint rotations were comparable to those previously documented for live dogs. After TKR, kinematics recorded for the 8°, 5-mm implant most closely resembled those of unaltered stifle joints. Decreasing the plateau angle and increasing spacer thickness altered stifle joint adduction, internal rotation, and medial translation. Medial collateral ligament strain was minimal in unaltered stifle joints and was unaffected by TKR. Lateral collateral ligament strain decreased with steeper plateau angles but returned to a presurgical level at the flattest plateau angle. Conclusions and Clinical Relevance—Among the constructs tested, greatest normalization of canine stifle joint kinematics in vitro was achieved with the steepest plateau angle paired with the thinnest spacer. Furthermore, results indicated that strain to the collateral ligaments was not negatively affected by .
Mostrar más [+] Menos [-]Absence of bactericidal effect of focused shock waves on an in-vitro biofilm model of an implant
2012
Madron, Matthew S. | McClure, Scott R. | Griffith, Ronald W. | Wang, Chong
The objective of this study was to evaluate the bactericidal effect of shock waves (SWs) on gram-negative or gram-positive monocultured biofilms grown on an orthopedic implant in vitro. Cortical bone screws were individually cultured with Escherichia coli or Staphylococcus epidermidis to produce a biofilm. In each run of 8 screws, 6 screws were treated with shock waves and then sonicated to disrupt the biofilm. One screw was sonicated only and one was not shock waved or sonicated before sampling for plate count dilutions. Post-treatment serial dilutions and plate counts were done on an aliquot from the vial containing each screw to obtain the number of colony-forming units (CFUs). Shock waves were at a constant energy of 0.15 mJ/mm2. Pulse number and screw orientation were varied. A linear mixed-effects model was used with “treatment” as a fixed effect and “run” as a random effect. Pairwise comparisons of treatments were performed with Tukey-Cramer’s adjustment for P-values. Sonicated plate counts were greater than nonsonicated counts for each run. When all sonicated screws were compared to all nonsonicated screws, the counts were significantly increased (P = 0.0091). For each paired comparison between sonicated and shock wave treatment, the only significant difference was in the S. epidermidis biofilm treated at 2000 pulses in a horizontal position, which increased the post-treatment count (P = 0.0445). No bactericidal effects were seen on monocultured biofilms on cortical bone screws treated with shock waves.
Mostrar más [+] Menos [-]Effects of sterilization with hydrogen peroxide gas plasma, ethylene oxide, and steam on bioadhesive properties of nylon and polyethylene lines used for stabilization of canine stifle joints
2012
Gatineau, Matthieu | El-Warrak, Alexander O. | Bolliger, Christian | Mourez, Michael | Berthiaume, Frederic
Objective: To compare effects of sterilization with hydrogen peroxide gas plasma (HPGP), ethylene oxide, and steam on bioadhesive properties of nylon and polyethylene lines used for stabilization of canine stifle joints. Sample: Samples of a 36.3-kg test nylon leader line, 57.8-kg test nylon fishing line, and 2-mm ultrahigh–molecular weight polyethylene (UHMWPE) were used. Procedures: In this in vitro study, samples of nylon leader line, fishing line, and UHMWPE sterilized by use of HPGP, ethylene oxide, and steam or unsterilized samples were used. Bacterial adherence on unsterilized and sterilized samples was tested with Staphylococcus epidermidis and Escherichia coli. Five samples were examined for each line type and sterilization condition, and final colony counts were obtained. Results: Bacterial adherence was significantly affected by method of sterilization for all 3 line types. For most of the samples, bacterial adherence was similar or lower when HPGP sterilization was used, compared with results for sterilization via ethylene oxide and steam, respectively. Bacterial adherence was significantly higher for UHMWPE, compared with adherence for the nylon line, regardless of the sterilization method used. Bacterial adherence was higher for nylon fishing line than for nylon leader line for S epidermidis after ethylene oxide sterilization and for E coli after HPGP and ethylene oxide sterilization. Conclusions and Clinical Relevance: Effects of HPGP sterilization on bioadhesive properties of nylon and polyethylene lines compared favorably with those for ethylene oxide and steam sterilization. Also, nylon line may be a more suitable material than UHMWPE for suture prostheses on the basis of bacterial adherence properties.
Mostrar más [+] Menos [-]Use of biometry and keratometry for determining optimal power of intraocular lens implants in dogs
1991
Gaiddon, J. | Rosolen, S.G. | Steru, L. | Cook, C.S. | Peiffer, R. Jr
Axial length and corneal curvature were determined by use of A-scan ultrasonography and keratometry on both eyes of dogs of various breeds, sizes, and ages. Mean axial length was 20.43 +/- 1.48 mm; axial length was not related to age or sex, but was significantly greater (P = 0.047) in dogs of larger breeds. Mean corneal curvature was 39.94 +/- 2.61 diopters. Dogs of large breeds had significantly (P < 0.001) flatter corneas. Mild, roughly symmetric astigmatism was detected in a majority of dogs. Use of mean values in a theoretic artificial intraocular lens power equation suggests that aphakic dogs require an implant of approximately 40 diopters to achieve emmetropia.
Mostrar más [+] Menos [-]Mechanical properties of isolated loops of nylon leader material, polyethylene cord, and polyethylene tape and mechanical properties of those materials secured to cadaveric canine femurs via lateral femoral fabellae, toggles placed through bone tunnels, or bone anchors
2012
Objective: To determine mechanical properties of various prosthetic materials secured to cadaveric canine femurs via various methods and to compare results with those for isolated loops of prosthetic material. Sample: 80 femurs obtained from cadavers of skeletally mature large-breed dogs. Procedures: 10 femoral constructs in each of 8 groups (single circumfabellar loop of polyethylene cord, double loop of polyethylene tape secured via a bone anchor [BAPT], single or double circumfabellar loops of nylon leader material [CNL] or polyethylene tape [CPT], or single or double loops of polyethylene tape secured via a toggle placed through a bone tunnel [BTPT]) and 10 isolated loops of prosthetic material in each corresponding configuration were tested. Stress relaxation, creep, elongation, load at 3 mm of displacement, stiffness, and peak load at failure were determined. Results: 5 single CNL constructs failed before completion of testing. Double CNL and single circumfabellar polyethylene cord constructs had the lowest loads at 3 mm of displacement. Single and double CPT constructs had the highest stiffness. Double BTPT and CPT constructs had the highest peak loads at failure. Double BTPT, double CPT, and BAPT constructs were mechanically superior on the basis of lower creep and stress relaxation and higher stiffness and load at 3 mm of displacement versus other constructs. Stiffness of femoral constructs was 28% to 69% that of corresponding isolated prosthetic loops. Conclusions and Clinical Relevance: Double BTPT, double CPT, and BAPT constructs were mechanically superior to other constucts. Mechanical properties and methods of anchorage and securing of free ends of prostheses contributed to mechanical properties of constructs.
Mostrar más [+] Menos [-]Refractive state of aphakic and pseudophakic eyes of dogs
1993
Davidson, M.G. | Murphy, C.J. | Nasisse, M.P. | Hellkamp, A.S. | Olivero, D.K. | Brinkmann, M.C. | Campbell, L.H.
Streak retinoscopy was performed by 5 ophthalmologists on 256 eyes (191 dogs) to determine their postoperative refractive state after cataract extraction. Aphakic and pseudophakic eyes that had been implanted with 1 of 5 intraocular lenses (IOL) with dioptric powers ranging from +14.5 to +38 diopters (D) were studied. By use of ANOVA, breed and body type of dog and individual performing refraction were found to have no detectable effect on final refractive state. Mean refractive state of aphakic eyes was +14.4 +/- 2.10 D. Mean refractive state for different IOL powers was as follows: +14.5 D IOL = +11.54 +/- 1.18 D (n = 13); +30 D IOL = + 5.15 +/- 1.18 D (n = 105); +34.0 D IOL = +3.5 D (n = 1); +36 D IOL +2.34 +/- 0.73 D 9 (n = 61); and +38 D IOL = +1.41 +/- 0.56 D (n = 28). Residual hyperopia ranged from +0.5 D to +2.5 D with +38 D IOL, and no eyes were myopic (overcorrected) by use of any of the IOL studied. linear regression analysis of refractive state on IOL power for aU dogs predicted that dioptric strength of +41.53 D was necessary to best approximate emmetropia for the population as a whole. Body type of the dog had only slight effect (< 1.0 D) on predicted optimal IOL power. Further linear regression analysis of the 7 breeds studied predicted variations from +39.62 to +43.14 D in IOL powers necessary to approximate emmetropia. Results of the study support the routine use of canine IOL with dioptric strength of approximately +41.5 D in circumstances in which preoperative biometry and keratometry are not practical. The findings further suggest that, for the specific population of dogs studied, most of the dogs could be corrected to near emmetropia by use of a small range of IOL dioptric strengths, irrespective of body type or breed.
Mostrar más [+] Menos [-]Effect of homologous fibrin adhesive on callus formation and extracortical bone bridging around a porous-coated segmental endoprosthesis in dogs
1993
Roy, R.G. | Markel, M.D. | Lipowitz, A.J. | Gottsauner-Wolf, F. | Taswell, H.F. | Chao, E.Y.S.
Modular, porous-coated, titanium segmental endoprostheses were implanted bilaterally in the femoral diaphysis of 7 adult mixed-breed dogs. Autogenous bone graft in particle form was placed around the implant and bone. In 1 limb, homologous fibrin adhesive was mixed with the graft in situ before soft tissue closure. The contralateral limb was grafted in identical manner, but without fibrin adhesive, and served as a control. Radiography was performed immediately after surgery and 1, 2, 3, 4, 6, 8, 10, and 12 weeks later to assess callus area and bone remodeling. At 12 weeks, dogs were euthanatized and bone/ implant fixation strength was tested under torsion and compared with values for 6 in vitro controls. Histomorphometric and microradiographic analyses of transverse sections of the distal portion of the implanted femurs were performed. Radiographic callus area was significantly (P < 0.05) smaller in the femurs grafted with fibrin adhesive, compared with the contralateral control. New bone formation (21.4 +/- 1.8% vs 19.2 +/- 2.4%), unlabeled bone (64.8 +/- 3.0% vs 67.9 +/- 4.2%), porosity (13.9 +/- 0.7% vs 12.9 +/- .8%), and bone ingrowth into the porous coating (10.3 +/- 0.9% vs 10.0 +/- 1.2%) were not significantly different between fibrin- and nonfibrin-grafted implants, respectively. There were no significant differences in torsional strength of implant fixation between the fibrin- and nonfibrin-grafted femurs or between the in vivo implanted femurs and the in vitro controls. These data indicate that fibrin adhesive may have been advantageous in maintaining apposition of bone graft adjacent to the endoprosthesis, but it probably did not have an enhancing effect on extracortical bone bridging or ingrowth over a porous-coated segmental bone replacement endoprosthesis.
Mostrar más [+] Menos [-]