Refinar búsqueda
Resultados 1-10 de 16
Efficacy of prosthetic laryngoplasty with and without bilateral ventriculocordectomy as treatments for laryngeal hemiplegia in horses.
1996
Tetens J. | Derksen F.J. | Stick J.A. | Lloyd J.W. | Robinson N.E.
Therapeutic effects of revascularisation on the healing of free bone grafts in dogs
2020
Zheng, Jia-San | Ruan, Hong-Ri | Shuang-Qiu, | Jing-Nie, | Hou, Kai-Wen | Rui-Wu,
The therapeutic effect of subcutaneous embedding and revascularisation on the repair of canine bone defects caused by open fracture was examined. A total of 12 adult beagle dogs were randomly split into a control group (group C) and a test group (group T). A section of the radius was removed from each dog under general anaesthesia and the deficit supported by an orthopaedic implant. Group T had the section surgically implanted next to the blood vessel–rich saphenous vein and Group C had it cryopreserved at −80°C. After eight weeks, the bone was surgically implanted back into the matching radial deficit. Bone healing was evaluated by gross morphological and X-ray examinations, post-mortem histology, and successive blood measurements of key bone biochemical markers. At 12 weeks, the bone healing boundary was disappearing more quickly in group T dogs than in their group C counterparts. X-ray and histological examinations showed that the cortical repair of group T subjects was complete and the bony plate arrangement was more regular than that in group C. The levels of bone biochemical markers also proved that the healing state of group T was better. The results showed that the degree of healing, osteoclast activity, and bone formation status of group T were better than those of group C, proving that the vascularised bone graft had a significantly shorter healing time than the cryopreserved bone graft.
Mostrar más [+] Menos [-]Ex vivo computed tomography evaluation of loading position on morphometry of the caudal cervical intervertebral disk spaces of dogs
2019
Knell, Sebastian C. | Smolders, Lucas A. | Steffen, Thomas | Pozzi, Antonio
OBJECTIVE To provide an objective, quantitative morphometric description of the caudal cervical intervertebral disk (IVD) spaces of dogs. SAMPLE Vertebral specimens consisting of C4 through C7 from 5 medium-sized dogs. PROCEDURES CT images were obtained with the specimens positioned in neutral, flexion, extension, and lateral bending positions. Size and shape of the cranial and caudal end plates, angle between the end plates (IVD wedge angle), and craniocaudal distance (IVD width) between end plates for the 4 loading positions were measured and compared for the 3 segments (C4-5, C5-6, and C6-7). RESULTS End plate size and shape, IVD wedge angle, and IVD width were not significantly different among the 3 segments. Caudal cervical end plates were consistently larger than cranial cervical end plates. The IVD wedge angle ranged from −4.8° to 15.2°. Flexion induced a reduction in IVD width in the ventral portion of the IVD, whereas extension induced a decrease in width in the dorsal portion of the IVD. Central IVD width remained unchanged among the loading positions. CONCLUSIONS AND CLINICAL RELEVANCE Unique morphometric and dynamic characteristics of the caudal cervical IVD space of dogs were detected. These findings may help investigators when designing IVD prostheses for dogs with cervical spondylomyelopathy.
Mostrar más [+] Menos [-]Passive ureteral dilation and ureteroscopy after ureteral stent placement in five healthy Beagles
2017
Vachon, Catherine | Defarges, Alice | Brisson, Brigitte | Nykamp, Stephanie | Weese, J Scott | Denstedt, John | Berent, Allyson C.
OBJECTIVE To determine whether passive ureteral dilation (PUD) would occur after an indwelling ureteral stent was left in place in healthy dogs for 2 or 6 weeks, ureteroscopy would be possible at the time of stent removal, and PUD would be reversible after stent removal. ANIMALS 5 healthy adult female Beagles. PROCEDURES A ureteral stent was cystoscopically placed in each ureter of each dog with fluoroscopic guidance (week 0). One stent was removed from 1 ureter in each dog after 2 weeks (ureter group 1), and the other was removed after 6 weeks (ureter group 2); removal timing was randomized. Computed tomographic excretory urography was performed every 2 weeks from weeks 0 through 10 to measure ureteral diameters. Ureteroscopy was attempted at the time of ureteral stent removal in each group. Ureteral diameters were compared among measurement points. RESULTS The degree of PUD was significant after 2 and 6 weeks of stent placement in both ureter groups. Mean diameter of the midportion of the ureter in both groups prior to stent placement was 1.70 mm (range, 1.3 to 2.7 mm). At stent removal, mean diameter of the midportion of the ureter was 2.86 mm (range, 2.4 to 3.1 mm) in group 1 and 2.80 mm (range, 2.1 to 3.4 mm) in group 2. Ureteroscopy was successfully performed in all dogs up to the renal pelvis. Compared with week 0 values for diameter of the midportion of the ureter, the degree of PUD induced by stent placement had reversed by week 8 in group 1 (mean diameter, 2.00 mm [range, 1.5 to 2.3 mm]). CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that ureteral stent placement for 2 weeks would result in sufficient PUD in healthy dogs to allow ureteroscopy at the time of stent removal and that the original ureteral diameter would eventually be restored. Additional research is needed to determine whether findings would be similar for dogs with urinary tract disease.
Mostrar más [+] Menos [-]In vitro effects of meloxicam on metabolism in articular chondrocytes from dogs with naturally occurring osteoarthritis
2013
Budsberg, Steven C. | Stoker, Aaron M. | Johnston, Spencer A. | Liska, William | Reno, Lisa R. | Coock, James L.
Objective-To assess effects of in vitro meloxicam exposure on metabolism in articular chondrocytes from dogs with naturally occurring osteoarthritis Sample-Femoral head cartilage from 16 dogs undergoing total hip replacement Procedures-Articular cartilage samples were obtained. Tissue sulfated glycosaminoglycan (SGAG), collagen, and DNA concentrations were measured. Collagen, SGAG, chondroitin sulfate 846, NO, prostaglandin E2 (PGE2), and matrix metalloproteinase (MMP)-2, MMP-3, MMP-9, and MMP-13 concentrations in culture medium were analyzed. Aggrecan, collagen II, MMP-2, MMP-3, MMP-9, MMP-13, ADAM metallopeptidase with thrombospondin type 1 motif (ADAMTS)-4, ADAMTS-5, tissue inhibitor of metalloproteinase (TIMP)-1, TIMP-2, TIMP-3, interleukin-1β, tumor necrosis factor-α, cyclooxygenase-1, cyclooxygenase-2, and nducible nitric oxide synthase gene expression were evaluated. Comparisons between tissues cultured without (control) and with meloxicam at concentrations of 0.3, 3.0, and 30.0 μg/mL for up to 30 days were performed by means of repeated-measures analysis. Results-Meloxicam had no effect on chondrocyte SGAG, collagen, or DNA concentrations. Expression of ADAMTS-5 was significantly decreased in all groups on all days, compared with the day 0 value. On day 3, culture medium PGE2 concentrations were significantly lower in all meloxicam-treated groups, compared with values for controls, and values remained low. Culture medium MMP-3 concentrations were significantly lower on day 30 than on day 3 in all meloxicam-treated groups. Conclusions and Clinical Relevance-Results suggested that in vitro meloxicam treatment of osteoarthritic canine cartilage for up to 30 days did not induce matrix degradation or stimulate MMP production. Meloxicam lowered PGE2 release from this tissue, and effects on tissue chondrocyte content and matrix composition were neutral.
Mostrar más [+] Menos [-]Development and validation of a canine radius replica for mechanical testing of orthopedic implants
2012
Little, Jeffrey P. | Horn, Timothy J. | Marcellin-Little, Denis J. | Harrysson, Ola L.A. | West, Harvey A II
Objective-To design and fabricate fiberglass-reinforced composite (FRC) replicas of a canine radius and compare their mechanical properties with those of radii from dog cadavers. Sample-Replicas based on 3 FRC formulations with 33%, 50%, or 60% short-length discontinuous fiberglass by weight (7 replicas/group) and 5 radii from large (> 30-kg) dog cadavers. Procedures-Bones and FRC replicas underwent nondestructive mechanical testing including 4-point bending, axial loading, and torsion and destructive testing to failure during 4-point bending. Axial, internal and external torsional, and bending stiffnesses were calculated. Axial pullout loads for bone screws placed in the replicas and cadaveric radii were also assessed. Results-Axial, internal and external torsional, and 4-point bending stiffnesses of FRC replicas increased significantly with increasing fiberglass content. The 4-point bending stiffness of 33% and 50% FRC replicas and axial and internal torsional stiffnesses of 33% FRC replicas were equivalent to the cadaveric bone stiffnesses. Ultimate 4-point bending loads did not differ significantly between FRC replicas and bones. Ultimate screw pullout loads did not differ significantly between 33% or 50% FRC replicas and bones. Mechanical property variability (coefficient of variation) of cadaveric radii was approximately 2 to 19 times that of FRC replicas, depending on loading protocols. Conclusions and Clinical Relevance-Within the range of properties tested, FRC replicas had mechanical properties equivalent to and mechanical property variability less than those of radii from dog cadavers. Results indicated that FRC replicas may be a useful alternative to cadaveric bones for biomechanical testing of canine bone constructs.
Mostrar más [+] Menos [-]Use of biometry and keratometry for determining optimal power of intraocular lens implants in dogs
1991
Gaiddon, J. | Rosolen, S.G. | Steru, L. | Cook, C.S. | Peiffer, R. Jr
Axial length and corneal curvature were determined by use of A-scan ultrasonography and keratometry on both eyes of dogs of various breeds, sizes, and ages. Mean axial length was 20.43 +/- 1.48 mm; axial length was not related to age or sex, but was significantly greater (P = 0.047) in dogs of larger breeds. Mean corneal curvature was 39.94 +/- 2.61 diopters. Dogs of large breeds had significantly (P < 0.001) flatter corneas. Mild, roughly symmetric astigmatism was detected in a majority of dogs. Use of mean values in a theoretic artificial intraocular lens power equation suggests that aphakic dogs require an implant of approximately 40 diopters to achieve emmetropia.
Mostrar más [+] Menos [-]Ex vivo modeling of the airflow dynamics and two-and three-dimensional biomechanical effects of suture placements for prosthetic laryngoplasty in horse
2020
Lynch, Nicola P. | Jones, Sarah A. | Bazley-White, Lucy G. | Wilson, Zoe F. | Raffetto, Jennifer | Pfau, Thilo | Cheetham, Jonathon | Perkins, Justin D.
OBJECTIVE To identify the degree of left arytenoid cartilage (LAC) abduction that allows laryngeal airflow similar to that in galloping horses, assess 2-D and 3-D biomechanical effects of prosthetic laryngoplasty on LAC movement and airflow, and determine the influence of suture position through the muscular process of the arytenoid cartilage (MPA) on these variables. SAMPLE 7 equine cadaver larynges. PROCEDURES With the right arytenoid cartilage maximally abducted and inspiratory airflow simulated by vacuum, laryngeal airflow and translaryngeal pressure and impedance were measured at 12 incremental LAC abduction forces (0% to 100% [maximum abduction]) applied through laryngoplasty sutures passed caudocranially or mediolaterally through the left MPA. Cross-sectional area of the rima glottis and left-to-right angle quotient were determined from photographs at each abduction force; CT images were obtained at alternate forces. Arytenoid and cricoid cartilage markers allowed calculation of LAC roll, pitch, and yaw through use of Euler angles on 3-D reconstructed CT images. RESULTS Translaryngeal pressure and impedance decreased, and airflow increased rapidly at low abduction forces, then slowed until a plateau was reached at approximately 50% of maximum abduction force. The greatest LAC motion was rocking (pitch). Suture position through the left MPA did not significantly affect airflow data. Approximately 50% of maximum abduction force, corresponding to a left arytenoid angle of approximately 30° and left-to-right angle quotient of 0.79 to 0.84, allowed airflow of approximately 61 ± 6.5 L/s. CONCLUSIONS AND CLINICAL RELEVANCE Ex vivo modeling results suggested little benefit to LAC abduction forces > 50%, which allowed airflow similar to that reported elsewhere for galloping horses.
Mostrar más [+] Menos [-]Mechanical properties of isolated loops of nylon leader material, polyethylene cord, and polyethylene tape and mechanical properties of those materials secured to cadaveric canine femurs via lateral femoral fabellae, toggles placed through bone tunnels, or bone anchors
2012
Objective: To determine mechanical properties of various prosthetic materials secured to cadaveric canine femurs via various methods and to compare results with those for isolated loops of prosthetic material. Sample: 80 femurs obtained from cadavers of skeletally mature large-breed dogs. Procedures: 10 femoral constructs in each of 8 groups (single circumfabellar loop of polyethylene cord, double loop of polyethylene tape secured via a bone anchor [BAPT], single or double circumfabellar loops of nylon leader material [CNL] or polyethylene tape [CPT], or single or double loops of polyethylene tape secured via a toggle placed through a bone tunnel [BTPT]) and 10 isolated loops of prosthetic material in each corresponding configuration were tested. Stress relaxation, creep, elongation, load at 3 mm of displacement, stiffness, and peak load at failure were determined. Results: 5 single CNL constructs failed before completion of testing. Double CNL and single circumfabellar polyethylene cord constructs had the lowest loads at 3 mm of displacement. Single and double CPT constructs had the highest stiffness. Double BTPT and CPT constructs had the highest peak loads at failure. Double BTPT, double CPT, and BAPT constructs were mechanically superior on the basis of lower creep and stress relaxation and higher stiffness and load at 3 mm of displacement versus other constructs. Stiffness of femoral constructs was 28% to 69% that of corresponding isolated prosthetic loops. Conclusions and Clinical Relevance: Double BTPT, double CPT, and BAPT constructs were mechanically superior to other constucts. Mechanical properties and methods of anchorage and securing of free ends of prostheses contributed to mechanical properties of constructs.
Mostrar más [+] Menos [-]Refractive state of aphakic and pseudophakic eyes of dogs
1993
Davidson, M.G. | Murphy, C.J. | Nasisse, M.P. | Hellkamp, A.S. | Olivero, D.K. | Brinkmann, M.C. | Campbell, L.H.
Streak retinoscopy was performed by 5 ophthalmologists on 256 eyes (191 dogs) to determine their postoperative refractive state after cataract extraction. Aphakic and pseudophakic eyes that had been implanted with 1 of 5 intraocular lenses (IOL) with dioptric powers ranging from +14.5 to +38 diopters (D) were studied. By use of ANOVA, breed and body type of dog and individual performing refraction were found to have no detectable effect on final refractive state. Mean refractive state of aphakic eyes was +14.4 +/- 2.10 D. Mean refractive state for different IOL powers was as follows: +14.5 D IOL = +11.54 +/- 1.18 D (n = 13); +30 D IOL = + 5.15 +/- 1.18 D (n = 105); +34.0 D IOL = +3.5 D (n = 1); +36 D IOL +2.34 +/- 0.73 D 9 (n = 61); and +38 D IOL = +1.41 +/- 0.56 D (n = 28). Residual hyperopia ranged from +0.5 D to +2.5 D with +38 D IOL, and no eyes were myopic (overcorrected) by use of any of the IOL studied. linear regression analysis of refractive state on IOL power for aU dogs predicted that dioptric strength of +41.53 D was necessary to best approximate emmetropia for the population as a whole. Body type of the dog had only slight effect (< 1.0 D) on predicted optimal IOL power. Further linear regression analysis of the 7 breeds studied predicted variations from +39.62 to +43.14 D in IOL powers necessary to approximate emmetropia. Results of the study support the routine use of canine IOL with dioptric strength of approximately +41.5 D in circumstances in which preoperative biometry and keratometry are not practical. The findings further suggest that, for the specific population of dogs studied, most of the dogs could be corrected to near emmetropia by use of a small range of IOL dioptric strengths, irrespective of body type or breed.
Mostrar más [+] Menos [-]