Refinar búsqueda
Resultados 1-4 de 4
Human-parathormone assay for use in dogs: validation, sample handling studies, and parathyroid function testing.
1989
Torrance A.G. | Nachreiner R.
Ten commercially available parathormone (PTH) assays were competitively validated, using dilutional parallelism, intra-assay and interassay coefficients of variation, and sensitivity and measured responses of 2 dogs to calcium and EDTA infusions. A 2-site immunoradiometric assay for intact human-PTH was superior to the others for estimating canine-PTH, met the criteria for validity, and was further investigated. A series of sample-handling studies was performed. Serum and plasma samples stored at 24 C lost 15% (n = 5; P less than 0.05) of PTH between 2 and 24 hours. This did not occur at 6 C. The mean PTH concentration of sera from blood samples clotted at 24 C was 6% (P less than 0.05) higher than equivalent EDTA samples. Serum samples stored at 6 and 37 C deteriorated 35% and 100% (n = 5; P less than 0.05), respectively, after 1 week, whereas samples stored at -20 and -70 C for 4 weeks did not deteriorate. There was no significant deterioration of PTH in samples frozen (-40 C) and thawed up to 7 times (n = 5). Parathyroid function testing was investigated by use of 2-hour infusions of disodium EDTA (25 mg/kg/h), 10-minute infusions of calcium gluconate (3 mg of elemental calcium/kg/10 min), and physiologic saline controls (n = 8). Renal function was monitored before and after EDTA infusion by exogenous creatinine clearance. Infusion of disodium EDTA increased mean PTH concentration from 67 (time 0) to 317 and 235 pg/ml at 90 and 180 minutes, respectively (P less than 0.001). Infusion of calcium gluconate decreased mean PTH concentration from 84 (time 0) to 14 and 12 pg/ml at 15 and 60 minutes, respectively (P less than 0.005). There were no observable side effects of the infusions in normal conscious dogs and no differences in exogenous creatinine clearance after EDTA infusion.
Mostrar más [+] Menos [-]Prevalence of bovid herpesvirus-4 and its antibody in cattle in Minnesota
1989
Naeem, K. | Goyal, S.M. | Werdin, R.E.
Serologic analyses and virus isolation studies were carried out to determine the role of bovid herpesvirus-4 (BHV-4) in infections in cattle, principally those of the reproductive tract. Serologic analyses were performed, using an indirect fluorescent antibody test on thoracic fluid specimens from aborted fetuses and on sera from 3 sources of adult cattle. Virus isolation was attempted from field cases of abortion, early embryo death, and postpartum vulvovaginitis/metritis, using uterine discharge and buffy coat preparations obtained from cows and tissues obtained from aborted fetuses. Of 420 fetal thoracic fluid specimens examined, 5 were positive for BHV-4 antibodies. Seventeen percent of adult cattle from 2 sources ie, clinically normal herds and abattoir cattle, were seropositive for BHV-4 antibodies. Cattle from a third source, 4 herds with high incidence of reproductive tract disorders, had a seroprevalence rate between 36 and 88%. Two isolates of BHV-4 were also obtained from this group. the overall incidence of BHV-4 antibodies in clinically normal cattle was higher than previously recognized, with relatively higher prevalence in herds having reproductive problems (chi-squared = 156.5, P less than 0.005). At least 10% of the BHV-4 antibody-positive sera did not have neutralizing antibody against bovine viral diarrhea virus and/or bovid herpesvirus-1, both important causes of bovine reproductive tract disorders.
Mostrar más [+] Menos [-]Human-parathormone assay for use in dogs: validation, sample handling studies, and parathyroid function testing
1989
Torrance, A.G. | Nachreiner, R.
Ten commercially available parathormone (PTH) assays were competitively validated, using dilutional parallelism, intra-assay and interassay coefficients of variation, and sensitivity and measured responses of 2 dogs to calcium and EDTA infusions. A 2-site immunoradiometric assay for intact human-PTH was superior to the others for estimating canine-PTH, met the criteria for validity, and was further investigated. A series of sample-handling studies was performed. Serum and plasma samples stored at 24 C lost 15% (n = 5; P less than 0.05) of PTH between 2 and 24 hours. This did not occur at 6 C. The mean PTH concentration of sera from blood samples clotted at 24 C was 6% (P less than 0.05) higher than equivalent EDTA samples. Serum samples stored at 6 and 37 C deteriorated 35% and 100% (n = 5; P less than 0.05), respectively, after 1 week, whereas samples stored at -20 and -70 C for 4 weeks did not deteriorate. There was no significant deterioration of PTH in samples frozen (-40 C) and thawed up to 7 times (n = 5). Parathyroid function testing was investigated by use of 2-hour infusions of disodium EDTA (25 mg/kg/h), 10-minute infusions of calcium gluconate (3 mg of elemental calcium/kg/10 min), and physiologic saline controls (n = 8). Renal function was monitored before and after EDTA infusion by exogenous creatinine clearance. Infusion of disodium EDTA increased mean PTH concentration from 67 (time 0) to 317 and 235 pg/ml at 90 and 180 minutes, respectively (P less than 0.001). Infusion of calcium gluconate decreased mean PTH concentration from 84 (time 0) to 14 and 12 pg/ml at 15 and 60 minutes, respectively (P less than 0.005). There were no observable side effects of the infusions in normal conscious dogs and no differences in exogenous creatinine clearance after EDTA infusion.
Mostrar más [+] Menos [-]Twenty-four hour urinary protein loss in healthy cats and the urinary protein-creatinine ratio as an estimate
1989
Monroe, W.E. | Davenport, D.J. | Saunders, G.K.
Urinary protein loss was determined in 12 healthy cats. Voided urine was collected and protein quantitated by the Coomassie blue method. Mean protein loss for all cats was 12.65 mg/kg24 h (5.45 SD). Protein loss for male cats (n=6) was 16.62 mg/kg24 h (3.3 SD), which was significantly different (P less than 0.01) from 8.69 mg/kg/24 h (4.09 SD) for females (n = 6). A single urine protein-creatinine ratio correlated well with the total urinary protein loss in mg/kg/24 h. The correlation coefficient for the protein-creatinine ratio in voided urine (UPCV) vs 24-hour urinary protein (UP-24) loss was 0.968, and that for the protein-creatinine ratio in urine obtained by cystocentesis (UPCC) vs UP-24 was 0.945. The regression equations were UPCV = 0.02145 + 0.02338 x UP-24 (mg/kg), and UPCC = 0.02667 + 0.02133 x UP-24 (mg/kg). Using the mean value plus 3 SD of urinary protein loss from the healthy cats in this study, a healthy cat would be expected to have a urinary protein loss of less than 29 mg/kg/24 h. A protein-creatinine ratio from a single urine sample provides an accurate estimate of urinary protein loss in healthy cats.
Mostrar más [+] Menos [-]