Refinar búsqueda
Resultados 311-320 de 535
Cats and Toxoplasma gondii: A systematic review and meta-analysis in Iran Texto completo
2015
Rahimi, Mohammad T.(Mazandaran University of Medical Sciences Toxoplasmosis Research Centre ,Mazandaran University of Medical Sciences Sari Medical School Department of Parasitology and Mycology) | Daryani, Ahmad(Mazandaran University of Medical Sciences Toxoplasmosis Research Centre ,Mazandaran University of Medical Sciences Sari Medical School Department of Parasitology and Mycology) | Sarvi, Shahabeddin(Mazandaran University of Medical Sciences Toxoplasmosis Research Centre ,Mazandaran University of Medical Sciences Sari Medical School Department of Parasitology and Mycology) | Shokri, Azar(Mazandaran University of Medical Sciences Toxoplasmosis Research Centre ,Mazandaran University of Medical Sciences Sari Medical School Department of Parasitology and Mycology) | Ahmadpour, Ehsan(Mazandaran University of Medical Sciences Toxoplasmosis Research Centre ,Tabriz University of Medical Sciences Infectious and Tropical Diseases Research Centre) | Teshnizi, Saeed H.(Hormozgan University of Medical Science Paramedical School) | Mizani, Azade(Mazandaran University of Medical Sciences Toxoplasmosis Research Centre ,Mazandaran University of Medical Sciences Sari Medical School Department of Parasitology and Mycology) | Sharif, Mahdi(Mazandaran University of Medical Sciences Toxoplasmosis Research Centre ,Mazandaran University of Medical Sciences Sari Medical School Department of Parasitology and Mycology)
Toxoplasma gondii is a cosmopolitan zoonotic intracellular coccidian of the phylum Apicomplexa infecting warm-blooded animals and human beings. This protozoan causes a significant public health problem in humans and imposes considerable economic losses and damages to husbandry industries. The final host, cats, accounts for all of these significant burdens. Hence the present study was designed to analyse and review the overall prevalence rate of T. gondii infection in cats in Iran for the first time. In the present study data collection (published and unpublished papers, abstracts of proceedings of national parasitology congresses and dissertations) was systematically undertaken on electronic databases including PubMed, Google Scholar, Ebsco, Science Direct, Scopus, Magiran, Irandoc, IranMedex and Scientific Information Database. A total of 21 studies from 1975 to 2013 reporting prevalence of Toxoplasma infection in cats from different areas in Iran met the eligibility criteria. The pooled proportion of toxoplasmosis using the random-effect model amongst cats was estimated at 33.6% (95% confidence interval [CI] 22.05-46.41). The prevalence rate of cat toxoplasmosis in various regions of Iran ranged from 1.2% to 89.2%. Firstly, this study establishes a crude prevalence rate of T. gondii infection in cats. Secondly, it discusses the role of significant risk factors including sex, age and being either household or stray cats, in the epidemiology of the disease. Furthermore, the current study determines gaps and drawbacks in the prior studies that are useful to keep in mind to assist in designing more accurate investigations in future.
Mostrar más [+] Menos [-]Evaluation of three point-of-care meters and a portable veterinary chemistry analyzer for measurement of blood glucose concentrations in black-tailed prairie dogs (Cynomys ludovicianus) Texto completo
2015
Higbie, Christine T. | Eshar, David | Bello, Nora M.
OBJECTIVE To compare blood glucose concentrations of black-tailed prairie dogs (Cynomys ludovicianus) measured by use of a variety of portable analyzers with results from a laboratory biochemistry analyzer. SAMPLE Venous blood samples (3 mL) obtained from each of 16 healthy black-tailed prairie dogs. PROCEDURES A portion of each blood sample was used to measure glucose concentrations by use of an amperometric human point-of-care glucometer and a colorimetric species-specific portable blood glucose meter designed for veterinary use with both canine (code 5) and feline (code 7) settings. The remainder of each blood sample was placed into 2 tubes (one contained lithium heparin and the other contained no anticoagulant). A portable veterinary chemistry analyzer (PVCA) and a handheld analyzer were used to measure glucose concentration in heparinized blood. Serum glucose concentration was measured in the remaining portion by use of a biochemistry analyzer. A general linear mixed models approach was used to compare glucose concentrations and measurement bias obtained with the various measurement methods. RESULTS Measurement bias and differences in mean glucose concentrations were apparent with all measurement methods. In particular, the veterinary glucometer, whether used on the canine or feline setting, overestimated mean glucose concentrations, whereas the human glucometer, PVCA, and handheld analyzer underestimated mean glucose concentrations relative to the concentration obtained with the biochemistry analyzer. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that none of the measurement methods provided consistently accurate blood glucose concentrations of black-tailed prairie dogs, compared with values determined with a biochemistry analyzer.
Mostrar más [+] Menos [-]Assessment of the excretion time of electronic capsules placed in the intestinal lumen of cows with cecal dilatation-dislocation, healthy control cows, and cows with left displacement of the abomasum Texto completo
2015
Devaux, David J. A. L. | Lempen, Markus | Schelling, Ester | Koch, Volker M. | Meylan, Mireille
OBJECTIVE To analyze the transit time from various locations in the intestines of cows with cecal dilatation-dislocation (CDD), healthy control cows, and cows with left displacement of the abomasum (LDA). ANIMALS 15 cows with naturally occurring CDD (group 1), 14 healthy control cows (group 2), and 18 cows with LDA (group 3). PROCEDURES 5 electronic transmitters were encased in capsules and placed in the lumen of the ileum, cecum, proximal portion of the colon, and 2 locations in the spiral colon (colon 1 and colon 2) and used to measure the transit time (ie, time between placement in the lumen and excretion of the capsules from the rectum). Excretion time of the capsules from each intestinal segment was compared among groups. RESULTS Cows recovered well from surgery, except for 1 cow with relapse of CDD 4 days after surgery and 2 cows with incisional infection. High variability in capsule excretion times was observed for all examined intestinal segments in all groups. Significant differences were detected for the excretion time from the colon (greater in cows with CDD than in healthy control cows) and cecum (less in cows with LDA than in cows of the other 2 groups). CONCLUSIONS AND CLINICAL RELEVANCE The technique developed to measure excretion time of capsules from bovine intestines was safe and reliable; however, the large variability observed for all intestinal segments and all groups would appear to be a limitation for its use in assessment of intestinal transit time of cattle in future studies.
Mostrar más [+] Menos [-]Cardiovascular effects of dopamine hydrochloride and phenylephrine hydrochloride in healthy isoflurane-anesthetized New Zealand White rabbits (Oryctolagus cuniculus) Texto completo
2015
Gosliga, Jaclyn M. | Barter, Linda S.
OBJECTIVE To determine the cardiopulmonary effects of progressively increasing infusion rates of dopamine hydrochloride and phenylephrine hydrochloride in healthy adult New Zealand White rabbits anesthetized with isoflurane. ANIMALS 6 New Zealand White rabbits. (Oryctolagus cuniculus). PROCEDURES Each rabbit was anesthetized on 2 occasions (≥ 2 weeks apart) with isoflurane in oxygen at 1.5 times the published isoflurane minimum alveolar concentration of 2.07%. Carotid artery and pulmonary artery catheters were placed. During each anesthetic episode, each rabbit received 5 progressively increasing doses of either dopamine (5, 10, 15, 20, or 30 μg/kg/min) or phenylephrine (0.125, 0.25, 0.5, 1.0, and 2.0 μg/kg/min). Blood gas and cardiopulmonary measurements were obtained after a 20-minute equilibration period prior to administration of the first drug dose (baseline) and after each subsequent dose administration. RESULTS Dopamine increased stroke index at the highest infusion rate of 30 μg/kg/min; however, cardiac output and mean arterial blood pressure remained unchanged from baseline values. Administration of phenylephrine at a rate of 2 μg/kg/min increased mean arterial blood pressure to 62 mm Hg from the baseline value of 45 mm Hg. This was a result of an increase in systemic vascular resistance with a concomitant decrease in heart rate and no change in cardiac output. Blood lactate concentration increased with time when rabbits received either treatment. CONCLUSIONS AND CLINICAL RELEVANCE Within the dose range of 5 to 30 μg/kg/min, dopamine was not an effective treatment for isoflurane-induced hypotension in rabbits and phenylephrine was only minimally effective at a dose of 2 μg/kg/min.
Mostrar más [+] Menos [-]Effects of oxymorphone hydrochloride or hydromorphone hydrochloride on minimal alveolar concentration of desflurane in sheep Texto completo
2015
Sayre, Rebecca S. | Lepiz, Mauricio A. | Horsley, Kristen T. | Pashmakova, Medora B. | Barr, James W. | Washburn, Shannon E.
OBJECTIVE To establish the minimum alveolar concentration (MAC) of desflurane and evaluate the effects of 2 opioids on MAC in sheep. ANIMALS 8 adult nulliparous mixed-breed sheep. PROCEDURES A randomized crossover design was used. Each sheep was evaluated individually on 2 occasions (to allow assessment of the effects of each of 2 opioids), separated by a minimum of 10 days. On each occasion, sheep were anesthetized with desflurane in 100% oxygen, MAC of desflurane was determined, oxymorphone (0.05 mg/kg) or hydromorphone (0.10 mg/kg) was administered IV, and MAC was redetermined. Physiologic variables and arterial blood gas and electrolyte concentrations were measured at baseline (before MAC determination, with end-tidal desflurane concentration maintained at 10%) and each time MAC was determined. Timing of various stages of anesthesia was recorded for both occasions. RESULTS Mean ± SEM MAC of desflurane was 8.6 ± 0.2%. Oxymorphone or hydromorphone administration resulted in significantly lower MAC (7.6 ± 0.4% and 7.9 ± 0.2%, respectively). Cardiac output at MAC determination for desflurane alone and for desflurane with opioid administration was higher than that at baseline. No difference was identified among hematologic values at any point. Effects of oxymorphone and hydromorphone on durations of various stages of anesthesia did not differ significantly. CONCLUSIONS AND CLINICAL RELEVANCE MAC of desflurane in nulliparous adult sheep was established. Intravenous administration of oxymorphone or hydromorphone led to a decrease in MAC; however, the clinical importance of that decrease was minor relative to the effect in other species.
Mostrar más [+] Menos [-]Indirect prediction of total body water content in healthy adult Beagles by single-frequency bioelectrical impedance analysis Texto completo
2015
Yaguiyan-Colliard, Laurence | Daumas, Caroline | Bousbiat, Sana | Jaffrin, Michel | Cardot, Philippe | Grandjean, Dominique | Priymenko, Nathalie | Nguyen, Patrick | Roux, Francise
OBJECTIVE To develop equations for prediction of total body water (TBW) content in unsedated dogs by combining impedance (resistance and reactance) and morphological variables and to compare the results of those equations with TBW content determined by deuterium dilution (TBWd). ANIMALS 26 healthy adult Beagles. PROCEDURES TBW content was determined directly by deuterium dilution and indirectly with equations developed from measurements obtained by use of a portable bioelectric impedance device and morphological variables including body length, height, weight, and thoracic and abdominal circumferences. RESULTS Impedance and morphological data from 16 of the 26 dogs were used to determine coefficients for the following 2 equations: TBW1 = −0.019 (BL2/R) + −0.199 (RC + AC) + 0.996W + 0.081H + 12.31; and TBW2 = 0.048 (BL2/R) + −0.144 (RC + AC) + 0.777W + 0.066H + 0.031X + 7.47, where AC is abdominal circumference, H is height, BL is body length, R is resistance, RC is rib cage circumference, W is body weight, and × is reactance. Results for TBW1 (R21 = 0.843) and TBW2 (R22 = 0.816) were highly correlated with the TBWd. When the equations were validated with data from the remaining 10 dogs, the respective mean differences between TBWd and TBW1 and TBW2 were 0.17 and 0.11 L, which equated to a nonsignificant underestimation of TBW content by 2.4% and 1.6%, respectively. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that impedance and morphological data can be used to accurately estimate TBW content in adult Beagles. This method of estimating TBW content is less expensive and easier to perform than is measurement of TBWd, making it appealing for daily use in veterinary practice.
Mostrar más [+] Menos [-]Risk factors for carriage of antimicrobial-resistant Salmonella spp and Escherichia coli in pet dogs from volunteer households in Ontario, Canada, in 2005 and 2006 Texto completo
2015
Leonard, Erin K. | Pearl, David L. | Janecko, Nicol | Finley, Rita L. | Reid-Smith, Richard J. | Weese, J Scott | Peregrine, Andrew S.
OBJECTIVE To determine pet-related management factors associated with the carriage of antimicrobial-resistant Salmonella spp and Escherichia coli in a population of pet dogs. SAMPLE 138 dogs from 84 households in Ontario, Canada. PROCEDURES From October 2005 through May 2006, dogs and households in Ontario, Canada, were recruited to participate in a cross-sectional study. Fecal samples were submitted for culture of Salmonella spp and E coli, which provided 515 bacterial isolates for antimicrobial susceptibility testing. Multilevel logistic regression models with random effects for household and dog were created to identify pet-related management factors associated with antimicrobial resistance. RESULTS Bacterial species, feeding a homemade diet or adding homemade food to the diet, feeding a raw diet or adding anything raw to the diet, feeding a homemade raw food diet, and feeding raw chicken in the past week were significant risk factors for antimicrobial resistance in this population of dogs. CONCLUSIONS AND CLINICAL RELEVANCE In this study, several potentially important pet-related risk factors for the carriage of antimicrobial-resistant Salmonella spp and E coli in pet dogs were identified. Further evaluation of risk factors for antimicrobial resistance in dogs may lead to development of evidence-based guidelines for safe and responsible dog ownership and management to protect the public, especially pet owners who are immunocompromised.
Mostrar más [+] Menos [-]Pharmacokinetics of butorphanol delivered with an osmotic pump during a seven-day period in common peafowl (Pavo cristatus) Texto completo
2015
Clancy, Meredith M. | Kukanich, Butch | Sykes, John M IV
OBJECTIVE To determine pharmacokinetics of butorphanol delivered via osmotic pumps in common peafowl (Pavo cristatus) as a method for analgesic administration to avian species. ANIMALS 14 healthy adult male common peafowl. PROCEDURES A preliminary experiment was conducted with 2 birds to establish time point and concentration requirements. Then, the remaining 12 birds were anesthetized, and 2 osmotic pumps containing butorphanol (volume, 2 mL; mean dosage, 247 μg/kg/h) were implanted subcutaneously in each bird for 7 days prior to removal. Blood samples were collected before pump implantation (time 0); 3, 6, 12, 24, 48, 72, 96, 120, 144, and 168 hours after pump implantation; and 3 and 6 hours after pump removal. Plasma butorphanol concentrations were measured via liquid chromatography–mass spectrometry. RESULTS Plasma concentrations peaked (mean, 106.4 μg/L; range, 61.8 to 133.0 μg/L) at a mean of 39.0 hours, with no evidence of sedation in any bird. After pump removal, butorphanol was rapidly eliminated (half-life, 1.45 hours; range, 1.31 to 1.64 hours; n = 5). Mean clearance per fraction of dose absorbed was 2.89 L/kg/h (range, 2.00 to 5.55 L/kg/h). Mean amount of time the plasma butorphanol concentration was ≥ 60 μg/L was 85.6 hours (range, 3.5 to 155.3 hours). CONCLUSIONS AND CLINICAL RELEVANCE Plasma concentrations of butorphanol in common peafowl were maintained at or above reported efficacious analgesic concentrations. This study established a method for administering analgesics to avian patients without the need for frequent handling or injections. Use of these osmotic pumps may provide options for avian analgesia.
Mostrar más [+] Menos [-]Identification of Escherichia coli F4ac-binding proteins in porcine milk fat globule membrane Texto completo
2015
Novaković, Predrag | Huang, Yanyun Y. | Lockerbie, Betty | Shahriar, Farshid | Kelly, John | Gordon, John R. | Middleton, Dorothy M. | Loewen, Matthew E. | Kidney, Beverly A. | Simko, Elemir
F4ac-positive enterotoxigenic Escherichia coli (ETEC) must attach to the intestinal mucosa to cause diarrhea in piglets. Prevention of bacterial attachment to the intestinal mucosa is the most effective defense against ETEC-induced diarrhea. Porcine milk fat globule membranes (MFGM) were shown to be able to inhibit attachment of ETEC to the intestinal brush border; however, the specific components of porcine MFGM that inhibited attachment of ETEC to enterocytes were not identified. Accordingly, the purpose of this study was to identify F4ac-binding MFGM proteins by overlay Western blot and affinity chromatography. The proteome of porcine MFGM was characterized and the following F4ac-binding proteins were detected by overlay Western blot and affinity chromatography: lactadherin, butyrophilin, adipophilin, acyl-CoA synthetase 3, and fatty acid-binding protein 3. The biological function of these proteins was not investigated but it is possible that their interaction with F4ac fimbria interferes with bacterial attachment and colonization.
Mostrar más [+] Menos [-]Effect of histologic processing on dimensions of skin samples obtained from cat cadavers Texto completo
2015
Jeyakumar, Sakthila | Smith, Annette N. | Schleis, Stephanie E. | Cattley, Russell C. | Tillson, Michael | Henderson, Ralph A.
OBJECTIVE To determine changes in dimensions of feline skin samples as a result of histologic processing and to identify factors that contributed to changes in dimensions of skin samples after sample collection. SAMPLE Cadavers of 12 clinically normal cats. PROCEDURES Skin samples were obtained bilaterally from 3 locations (neck, thorax, and tibia) of each cadaver; half of the thoracic samples included underlying muscle. Length, width, and depth were measured at 5 time points (before excision, after excision, after application of ink to mark tissue margins, after fixation in neutral-buffered 10% formalin for 36 hours, and after completion of histologic processing and staining with H&E stain). Measurements obtained after sample collection were compared with measurements obtained before excision. RESULTS At the final time point, tissue samples had decreased in length (mean decrease, 32.40%) and width (mean decrease, 34.21%) and increased in depth (mean increase, 54.95%). Tissue from the tibia had the most shrinkage in length and width and that from the neck had the least shrinkage. Inclusion of underlying muscle on thoracic skin samples did not affect the degree of change in dimensions. CONCLUSIONS AND CLINICAL RELEVANCE In this study, each step during processing from excision to formalin fixation and histologic processing induced changes in tissue dimensions, which were manifested principally as shrinkage in length and width and increase in depth. Most of the changes occured during histologic processing. Inclusion of muscle did not affect thoracic skin shrinkage. Shrinkage should be a consideration when interpreting surgical margins in clinical cases.
Mostrar más [+] Menos [-]