Refinar búsqueda
Resultados 581-590 de 766
Evaluation of a portable media device for use in determining postural stability in standing horses Texto completo
2017
Moorman, Valerie J. | Kawcak, Christopher E. | King, Melissa R.
OBJECTIVE To determine the ability of an accelerometer within a commercially available portable media device (PMD) to measure changes in postural stability of standing horses during various stance conditions and to compare these results with data obtained by use of a stationary force platform. ANIMALS 7 clinically normal horses. PROCEDURES A PMD was mounted on a surcingle; the surcingle was placed immediately caudal to the highest point of the shoulders (withers). Each horse was examined while standing on a stationary force platform system in a normal square stance, forelimb base-narrow stance, and normal square stance at 5 and 10 minutes after sedation induced by IV administration of xylazine hydrochloride. A minimum of 5 trials were conducted for each stance condition. Ranges of craniocaudal and mediolateral motion as well as SDs were collected for the PMD and force platform system. Analyses were performed with mixed-model ANOVAs, and correlation coefficients were calculated. RESULTS Stance condition significantly altered craniocaudal accelerations measured by use of the PMD, all craniocaudal and mediolateral displacements of the center of pressure, and velocities measured by use of the stationary force platform. For both the PMD and force platform, SDs were significantly affected by stance condition in both craniocaudal and mediolateral directions. Correlation coefficients between the systems for all variables were low to moderate (r = 0.18 to 0.58). CONCLUSIONS AND CLINICAL RELEVANCE Body-mounted PMDs should be investigated for use in assessment of postural stability in horses with neuromuscular abnormalities.
Mostrar más [+] Menos [-]Evaluation of canine hepatic masses by use of triphasic computed tomography and B-mode, color flow, power, and pulsed-wave Doppler ultrasonography and correlation with histopathologic classification Texto completo
2017
Griebie, Erin R. | David, Frederic H. | Ober, Christopher P. | Feeney, Daniel A. | Anderson, Kari L. | Wuenschumann, Arno | Jessen, Carl R.
OBJECTIVE To determine clinical relevance for quantitative and qualitative features of canine hepatic masses evaluated by use of triphasic CT and B-mode, color flow, power, and pulsed-wave Doppler ultrasonography and to compare diagnostic accuracy of these modalities for predicting mass type on the basis of histopathologic classification. ANIMALS 44 client-owned dogs. PROCEDURES Dogs with histopathologic confirmation (needle core, punch, or excisional biopsy) of a hepatic mass were enrolled. Triphasic CT and B-mode, color flow, power, and pulsed-wave Doppler ultrasonography of each hepatic mass were performed. Seventy quantitative and qualitative variables of each hepatic mass were recorded by 5 separate observers and statistically evaluated with discriminant and stepwise analyses. Significant variables were entered in equation-based predictions for the histopathologic diagnosis. RESULTS An equation that included the lowest delayed-phase absolute enhancement of the mass and the highest venous-phase mass conspicuity was used to correctly classify 43 of 46 (93.5%) hepatic masses as benign or malignant. An equation that included only the lowest delayed-phase absolute enhancement of the mass could be used to correctly classify 42 of 46 (91.3%) masses (with expectation of malignancy if this value was < 37 Hounsfield units). For ultrasonography, categorization of the masses with cavitations as malignant achieved a diagnostic accuracy of 80.4%. CONCLUSIONS AND CLINICAL RELEVANCE Triphasic CT had a higher accuracy than ultrasonography for use in predicting hepatic lesion classification. The lowest delayed-phase absolute enhancement of the mass was a simple calculation that required 2 measurements and aided in the differentiation of benign versus malignant hepatic masses.
Mostrar más [+] Menos [-]Maternal and fetal arterial blood gas data in normotensive, singleton, isoflurane anesthetized sheep at 124-126 days of gestation Texto completo
2017
Loughran, C. M. | Kemp, M. W. | Musk, G. C.
The aim of this case series was to describe the differences between maternal and fetal blood-gas results during anesthesia. Sixteen singleton adult merino ewes weighing 60.1 ± 5.1 kg at 125.7 d (124 to 126 d) gestation were anesthetized. Maternal (radial) and fetal (umbilical) arterial blood gas samples were collected 79 ± 6 min after the start of anesthesia if maternal mean arterial pressure (MAP) was stable and > 65 mmHg. Fetal pH, partial arterial pressure of oxygen (PaO2), glucose, arterial hemoglobin oxygen saturation (SaO2), sodium, and chloride were significantly lower and fetal partial arterial pressure of carbon dioxide (PaCO2), lactate, hematocrit, total hemoglobin, potassium, and calcium were significantly higher than maternal blood-gas values. Fetal pH, PaO2, and BE were lower and fetal lactate was higher than fetal umbilical arterial samples previously reported, which may indicate a non-reassuring fetal status. Further refinement of the ovine experimental model is warranted with fetal monitoring during maternal anesthesia.
Mostrar más [+] Menos [-]Ultrasonography as a complementary diagnostic method for evaluating the skin of healthy cats Texto completo
2017
Zanna, Giordana | Zini, Eric | Scarampella, Fabia | Attanasi, Anna | Arrighi, Silvana | Auriemma, Edoardo
Ultrasonography is not often used in feline dermatology. The purpose of this study was to assess the usefulness and applicability of ultrasonography for skin evaluation in 21 clinically healthy cats. Ultrasonographic examination was conducted in 4 cutaneous regions (frontal, dorsal neck, sacral, and abdominal) using an 18-MHz linear-sequential-array transducer. Findings were assessed using histomorphometric analysis of skin samples set as reference standards. Morphologic evaluation, thickness measurements, measurement variability, and comparison between regions and genders were carried out. The ultrasonographic pattern of feline skin was characterized by 3 distinct layers of different echogenicity and echostructure. Skin was thickest at the dorsal neck region and thinnest at the abdominal region. Skin at the frontal region and dorsal neck region was thicker in males. Variability was < 10% in all regions. No apparent correspondence was found between ultrasonographic and histometric measurements of skin thickness. Collectively, these findings suggest that ultrasonography is a simple, noninvasive, and reproducible technique that allows cutaneous layers to be identified and accurately measures skin thickness in cats.
Mostrar más [+] Menos [-]Effect of position and time held in that position on ground-glass opacity in computed tomography images of dogs Texto completo
2017
Yi, Sang-gwŏn | Park, , Seungjo | Cheon, Byunggyu | Moon, Sohyeon | Hong, Sunghwa | Cho, Hyun | Chang, Dongwoo | Choi, Jihye
OBJECTIVE To evaluate effects of position, time in that position, and positive end-expiratory pressure on ground-glass opacity caused by physiologic atelectasis on lung CT images and to determine effects of recumbency position before CT. ANIMALS 6 healthy Beagles. PROCEDURES In a crossover study, dogs were placed in 4 positions (sternal, dorsal, right lateral, and left lateral recumbency) for 2 holding times (30 and 60 minutes). Dogs were then repositioned in sternal recumbency, and CT was performed at 2 positive end-expiratory pressures (0 and 15 mm Hg). Location, distribution, and degree of ground-glass opacities were evaluated on lung CT images. Volume and mean density of the lungs and ground-glass opacities as well as maximum density of ground-glass opacities were evaluated. RESULTS Ground-glass opacities were mainly observed in parts of the lungs that were dependent during the various positions before CT, except for sternal recumbency. Opacities were reversible and decreased or disappeared after lung inflation. Ground-glass opacities were observed most frequently and had greatest severity when dogs were positioned in left lateral recumbency before CT. Ground-glass opacities were negligible for dogs positioned in sternal recumbency before CT. CONCLUSIONS AND CLINICAL RELEVANCE Location and reversibility of ground-glass opacities may help clinicians distinguish whether they are attributable to atelectasis or a result of pathological changes. Dogs should be positioned in sternal recumbency to minimize the occurrence of ground-glass opacities, particularly when several procedures are performed before CT, which increases the time that a dog will remain in the same position.
Mostrar más [+] Menos [-]Effects of diurnal variation and anesthetic agents on intraocular pressure in Syrian hamsters (Mesocricetus auratus) Texto completo
2017
Rajaei, Seyed Mehdi | Mood, Maneli Ansari | Paryani, Mohammad Reza | Williams, David L.
OBJECTIVE To determine effects of diurnal variation and anesthetic agents on intraocular pressure (IOP) in Syrian hamsters (Mesocricetus auratus). ANIMALS 90 healthy adult Syrian hamsters (45 males and 45 females). PROCEDURES IOP was measured with a rebound tonometer. In phase 1, IOP was measured in all hamsters 3 times during a 24-hour period (7 am, 3 pm, and 11 pm). In phase 2, hamsters were assigned to 5 groups (18 animals [9 males and 9 females]/group). Each group received an anesthetic agent or combination of anesthetic agents (ketamine hydrochloride, xylazine hydrochloride, diazepam, ketamine-diazepam [KD], or ketamine-xylazine [KX] groups) administered via the IP route. The IOP was measured before (time 0 [baseline]) and 10, 30, 60, 90, 120, and 150 minutes after administration of drugs. RESULTS Mean ± SD IOP values were 2.58 ± 0.87 mm Hg, 4.46 ± 1.58 mm Hg, and 5.96 ± 1.23 mm Hg at 7 am, 3 pm, and 11 pm, respectively. Mean baseline IOP was 6.25 ± 0.28 mm Hg, 6.12 ± 0.23 mm Hg, 5.75 ± 0.64 mm Hg, 5.12 ± 1.40 mm Hg, and 4.50 ± 1.30 mm Hg for the ketamine, xylazine, diazepam, KD, and KX groups, respectively. A significant decrease in IOP, compared with baseline IOP, was detected in only the KX group at 30, 60, and 90 minutes after drug administration. CONCLUSIONS AND CLINICAL RELEVANCE Maximum IOP in Syrian hamsters was detected at night. The ketamine-xylazine anesthetic combination significantly decreased IOP in Syrian hamsters.
Mostrar más [+] Menos [-]Histological and functional characterizations of the digital cushion in Quarter horses Texto completo
2017
Faramarzi, Babak | Lantz, Linnea | Lee, Dongbin | Khamas, Wael
The digital cushion (DC) plays a role in absorbing and dampening forces applied to the foot and therefore supports internal structures such as navicular bone; yet, its architecture is not well-known. The goal of this study was to characterize the microanatomical structure of the DC in horses with clinically sound hooves. Both forefeet from the cadavers of 12 adult Quarter horses were cut and sectioned and samples of the following 4 regions of the DC were obtained: axial proximal (AxProx), axial distal (AxDis), abaxial lateral (AbxLat), and abaxial medial (AbxMed). The samples were processed and stained with hematoxylin and eosin, Masson's trichrome, and Weigert's elastic stains. On each slide, 2 central 3- × 3-mm areas were microscopically assessed and all measurements were done within the 9-mm2 area. The number of detected collagen bundles, nerve fascicles, vessels, and the diameter of wall thickness and lumen of blood vessels were measured. Elastic fiber profiles were categorized based on relative density of elastic fibers detected in the field. The percentage of samples in which chondrocytes and adipose tissues were either present or absent was calculated. Significant structural differences were identified among the 4 regions of the DC. The AxDis region contained more collagen bundles (P < 0.0001) and less elastic fiber profiles than the AxProx region (P < 0.0001). The AxDis also contained more collagen bundles than the AbxMed and AbxLat (P < 0.0001) regions. Our findings provide insight into the structure of the DC of mature Quarter horses. The structural differences in the various regions of the DC are presumably related to the different functional properties of those regions; yet more research is warranted.
Mostrar más [+] Menos [-]The role of active transport in the transcellular movement of the peripheral α2-adrenoceptor antagonist, MK-467: An in vitro pilot study Texto completo
2017
Bennett, Rachel | Palviainen, Mari | Peltoniemi, Marikki | Vuorilehto, Lauri | Scheinin, Mika | Raekallio, Marja | Vainio, Outi
MK-467 is a peripherally acting α2-adrenoceptor antagonist due to its low lipid solubility and poor penetration of the blood-brain barrier (BBB). The aim of this study was to assess whether MK-467 could be a substrate of an active efflux transport mechanism. Using Madin-Darby Canine Kidney cells (MDCKII) and MDCKII cells transfected with the human multidrug resistance gene 1, drug transport was assessed in apical-basolateral and basolateral-apical directions. MK-467 was studied at 2 concentrations: 200 and 1000 ng/mL. Samples for analysis were taken at 15, 30, 45, 60, and 90 min after drug application. Drug concentrations were measured using liquid chromatography and mass spectrometry. MK-467 showed no apparent permeability in the apical-basolateral direction, transport in the basolateral-apical direction occurred in both cell lines. Efflux ratios were not calculated. However, MK-467 appeared to undergo active cellular transport. The identity of the transporter requires further investigation.
Mostrar más [+] Menos [-]Characterization of aminoaciduria and hypoaminoacidemia in dogs with hepatocutaneous syndrome Texto completo
2017
Loftus, John P. | Center, Sharon A. | Lucy, John M. | Stanton, Julie A. | McDonough, Sean P. | Peters-Kennedy, Jeanine | Arceneaux, Kenneth A. | Bechtold, Molly A. | Bennett, Courtney L. | Bradbury, Christina A. | Cline, Martha G. | Hall-Fonte, Deborah | Hammer-Landrum, Julie F. | Huntingford, Janice L. | Marshall, Jennifer | Sharpe, Kristopher S. | Redin, Jessica L. | Selva, Samuel T. | Lucia, Tomasina A.
OBJECTIVE To characterize aminoaciduria and plasma amino acid concentrations in dogs with hepatocutaneous syndrome (HCS). ANIMALS 20 client-owned dogs of various breeds and ages. PROCEDURES HCS was definitively diagnosed on the basis of liver biopsy specimens (n = 12), gross and histologic appearance of skin lesions (4), and examination of skin and liver biopsy specimens (2) and presumptively diagnosed on the basis of cutaneous lesions with compatible clinicopathologic and hepatic ultrasonographic (honeycomb or Swiss cheese pattern) findings (2). Amino acid concentrations in heparinized plasma and urine (samples obtained within 8 hours of each other) were measured by use of ion exchange chromatography. Urine creatinine concentration was used to normalize urine amino acid concentrations. Plasma amino acid values were compared relative to mean reference values; urine-corrected amino acid values were compared relative to maximal reference values. RESULTS All dogs had generalized hypoaminoacidemia, with numerous amino acid concentrations < 50% of mean reference values. The most consistent and severe abnormalities involved glutamine, proline, cysteine, and hydroxyproline, and all dogs had marked lysinuria. Urine amino acids exceeding maximum reference values (value > 1.0) included lysine, 1-methylhistidine, and proline. CONCLUSIONS AND CLINICAL RELEVANCE Hypoaminoacidemia in dogs with HCS prominently involved amino acids associated with the urea cycle and synthesis of glutathione and collagen. Marked lysinuria and prolinuria implicated dysfunction of specific amino acid transporters and wasting of amino acids essential for collagen synthesis. These findings may provide a means for tailoring nutritional support and for facilitating HCS diagnosis.
Mostrar más [+] Menos [-]Quality assessment of fluconazole capsules and oral suspensions compounded by pharmacies located in the United States Texto completo
2017
Laporte, Carnie M. | Cruz-Espindola, Crisanta | Thungrat, Kamoltip | Schick, Anthea E. | Lewis, Thomas P II | Boothe, Dawn M.
OBJECTIVE To evaluate pharmaceutical characteristics (strength or concentration, accuracy, and precision), physical properties, and bacterial contamination of fluconazole compounded products. SAMPLE Fluconazole compounded products (30- and 240-mg capsules; 30- and 100-mg/mL oral suspensions) from 4 US veterinary compounding pharmacies. PROCEDURES Fluconazole compounded products were ordered 3 times from each of 4 pharmacies at 7- or 10-day intervals. Generic fluconazole products (50- and 200-mg tablets; 10- and 40-mg/mL oral suspensions) served as references. Compounded products were evaluated at the time of receipt; suspensions also were evaluated 3 months later and at beyond-use dates. Evaluations included assessments of strength (concentration), accuracy, precision, physical properties, and bacterial contamination. Acceptable accuracy was defined as within ± 10% of the labeled strength (concentration) and acceptable precision as within ± 10%. Fluconazole was quantified by use of high-performance liquid chromatography. RESULTS Physical characteristics of compounded products differed among pharmacies. Aerobic bacterial cultures yielded negative results. Capsules (30 and 240 mg) had acceptable accuracy (median, 96.3%; range, 87.3% to 135.2%) and precision (mean ± SD, 7.4 ± 6.0%). Suspensions (30 and 100 mg/mL) had poor accuracy (median, 73.8%; range, 53.9% to 95.2%) and precision (mean ± SD, 15.0 ± 6.9%). Accuracy and precision were significantly better for capsules than for suspensions. CONCLUSIONS AND CLINICAL RELEVANCE Fluconazole compounded products, particularly suspensions, differed in pharmaceutical and physical qualities. Studies to evaluate the impact of inconsistent quality on bioavailability or clinical efficacy of compounded fluconazole products are indicated, and each study should include data on the quality of the compounded product evaluated.
Mostrar más [+] Menos [-]