Refinar búsqueda
Resultados 1-3 de 3
Differences between a deciduous and a conifer tree species in gaseous and particulate emissions from biomass burning
2018
Pallozzi, Emanuele | Lusini, Ilaria | Cherubini, Lucia | Hajiaghayeva, Ramilla A. | Ciccioli, Paolo | Calfapietra, Carlo
In the Mediterranean ecosystem, wildfires are very frequent and the predicted future with a probable increase of fires could drastically modify the vegetation scenarios. Vegetation fires are an important source of gases and primary emissions of fine carbonaceous particles in the atmosphere. In this paper, we present gaseous and particulate emissions data from the combustion of different plant tissues (needles/leaves, branches and needle/leaf litter), obtained from one conifer (Pinus halepensis) and one deciduous broadleaf tree (Quercus pubescens). Both species are commonly found throughout the Mediterranean area, often subject to wildfires. Experiments were carried out in a combustion chamber continuously sampling emissions throughout the different phases of a fire (pre-ignition, flaming and smoldering). We identified and quantified 83 volatile organic compounds including important carcinogens that can affect human health. CO and CO₂ were the main gaseous species emitted, benzene and toluene were the dominant aromatic hydrocarbons, methyl-vinyl-ketone and methyl-ethyl-ketone were the most abundant measured oxygenated volatile organic compounds. CO₂ and methane emissions peaked during the flaming phase, while the peak of CO emissions occurred during the smoldering phase. Overall, needle/leaf combustion released a greater amount of volatile organic compounds into the atmosphere than the combustion of branches and litter. There were few differences between emissions from the combustion of the two tree species, except for some compounds. The combustion of P. halepensis released a great amount of monoterpenes as α-pinene, β-pinene, p-cymene, sabinene, 3-carene, terpinolene and camphene that are not emitted from the combustion of Q. pubescens. The combustion of branches showed the longest duration of flaming and peak of temperature. Data presented appear crucial for modeling with the intent of understanding the loss of C during different phases of fire and how different typologies of biomass can affect wildfires and their speciation emissions profile.
Mostrar más [+] Menos [-]Review of plants to mitigate particulate matter, ozone as well as nitrogen dioxide air pollutants and applicable recommendations for green roofs in Montreal, Quebec
2018
Gourdji, Shannon
In urbanized regions with expansive impervious surfaces and often low vegetation cover, air pollution due to motor vehicles and other combustion sources, is a problem. The poor air quality days in Montreal, Quebec are mainly due to fine particulate matter and ozone. Businesses using wood ovens are a source of particulates. Careful vegetation selection and increased green roof usage can improve air quality. This paper reviews different green roofs and the capability of plants in particulate matter (PM), ozone (O3) as well as nitrogen dioxide (NO2) level reductions. Both the recommended green roof category and plants to reduce these pollutants in Montreal's zone 5 hardiness region are provided. Green roofs with larger vegetation including shrubs and trees, or intensive green roofs, remove air pollutants to a greater extent and are advisable to implement on existing, retrofitted or new buildings. PM is most effectively captured by pines. The small Pinus strobus ‘Nana’, Pinus mugho var. pumilio, Pinus mugho ‘Slowmound’ and Pinus pumila ‘Dwarf Blue’ are good candidates for intensive green roofs. Drought tolerant, deciduous broadleaved trees with low biogenic volatile organic compound emissions including Japanese Maple or Acer palmatum ‘Shaina’ and ‘Mikawa-Yatsubusa’ are options to reduce O3 levels. Magnolias are tolerant to NO2 and it is important in their metabolic pathways. The small cold-tolerant Magnolia ‘Genie’ is a good option to remove NO2 in urban settings and to indirectly reduce O3 formation. Given the emissions by Montreal businesses' wood ovens, calculations performed based on their respective complex roof areas obtained via Google Earth Pro indicates 88% Pinus mugho var. pumilio roof coverage can annually remove 92.37 kg of PM10 of which 35.10 kg is PM2.5. The removal rates are 4.00 g/m2 and 1.52 g/m2 for PM10 and PM2.5, respectively. This paper provides insight to addressing air pollution through urban rooftop greening.
Mostrar más [+] Menos [-]Immobilized atmospheric particulate matter on leaves of 96 urban plant species
2020
Muhammad, Samira | Wuyts, Karen | Samson, Roeland
Plants provide many ecosystem services in urban environments, including improving ambient air quality. Leaves of plants permit the deposition of particulate matter (PM) and, depending on their leaf traits, PM may be immobilized within the epicuticular wax (EW) layer, on trichomes, on hyphae of fungi, or inside stomatal cavities. In this study, leaves of 96 perennial urban plant species consisting of 45 deciduous broadleaf/needle-like trees, 32 deciduous broadleaf shrubs, 12 evergreen needle/scale-like trees, 5 evergreen broadleaf trees, and 2 climber species were investigated in June and September 2016 to determine the effectiveness of distinct leaf surfaces in PM immobilization after leaf washing treatment. The leaf surfaces were washed vigorously using a vortex shaker. The magnetizable component of accumulated and immobilized PM on the leaf surfaces was estimated using saturation isothermal remanent magnetization (SIRM) of the unwashed and washed leaves, respectively. In June, the washed leaf SIRM of deciduous (broadleaf/needle-like) tree and shrub species (n = 77) ranged between 0.1 and 13.9 μA. In September, the washed leaf SIRM of all investigated plant species (n = 96) ranged between 1.2 and 35.0 μA. Outcomes of this study indicate that leaves of Buddleja davidii, Viburnum lantana, and Sorbus intermedia showed the highest washed leaf SIRM and thus were the most effective in immobilizing PM on their leaf surfaces while leaves of Populus alba, Robinia pseudoacacia, and Abies fraseri with lowest washed leaf SIRM were the least effective. On average, more than half (i.e., 60%) of the magnetic signal still remained after vigorous washing but a large variation exists between species (9–96%). The leaf SIRM of washed leaves of deciduous broadleaf tree and shrub species was significantly higher compared to leaves of evergreen needle/scale-like species. Evidently, the magnetic signal of unwashed leaves was higher than washed ones and higher in September than in June. Leaf traits significantly influenced the magnetic signal of both washed and unwashed leaves: leaves with a high trichome density or high leaf wettability showed a higher unwashed and washed leaf SIRM compared to leaves with no trichomes or low leaf wettability. The effect of epicuticular wax structure types on leaf SIRM was indicated to be only marginally significant. Moreover, also the immobilized fraction of PM was significantly affected by trichome density and leaf wettability, thus substantiating that plant species with high trichome density and/or leaf wettability not only accumulate more PM but are also less prone to PM re-suspension than other species. In general, the results also indicate that leaf SIRM of unwashed leaves can be a good indicator to determine the effectiveness of a plant species in PM immobilization. Plant species effective in immobilizing PM on their leaf surfaces may likely improve ambient air quality when planted in urban environments. However, it is vital that leaves of these plant species (i.e., with high PM immobilization abilities) are carefully recycled as they may be polluted.
Mostrar más [+] Menos [-]