Refinar búsqueda
Resultados 331-340 de 646
Manual de los Reglamentos del Agua en Florida: Ley del Derecho-a-Granja de Florida Texto completo
2006
Michael T. Olexa | Luke D'Isernia | Laura Minton | Dulcy Miller | Sarah Corbett
Revised! This series is the Spanish language version of the Handbook of Florida Water Regulations by Michael T. Olexa, Luke D'Isernia, Laura Minton, Dulcy Miller, and Sara Corbett. Published by the UF Department of Food and Resource Economics, November 2006. FE082/FE082: Manual de los Reglamentos del Agua en Florida: Ley del Derecho-a-Granja de Florida (ufl.edu) Ask IFAS: Manual de los Reglamentos del Agua de Florida (ufl.edu)
Mostrar más [+] Menos [-]Manual de los Reglamentos del Agua en Florida: Ley de Restauración de Cuencas de Florida Texto completo
2006
Michael T. Olexa | Luke D'Isernia | Laura Minton | Dulcy Miller | Sarah Corbett
Revised! This series is the Spanish language version of the Handbook of Florida Water Regulations by Michael T. Olexa, Luke D'Isernia, Laura Minton, Dulcy Miller, and Sara Corbett. Published by the UF Department of Food and Resource Economics, November 2006. FE091/FE091: Manual de los Reglamentos del Agua en Florida: Ley de Restauración de Cuencas de Florida (ufl.edu) Ask IFAS: Manual de los Reglamentos del Agua de Florida (ufl.edu)
Mostrar más [+] Menos [-]Manual de los Reglamentos del Agua en Florida: Ley de los Eternos Everglades de Florida Texto completo
2006
Michael T. Olexa | Luke D'Isernia | Laura Minton | Dulcy Miller | Sarah Corbett
Revised! This series is the Spanish language version of the Handbook of Florida Water Regulations by Michael T. Olexa, Luke D'Isernia, Laura Minton, Dulcy Miller, and Sara Corbett. Published by the UF Department of Food and Resource Economics, November 2006. FE092/FE092: Manual de los Reglamentos del Agua en Florida: Ley de los Everglades para Siempre de Florida (ufl.edu) Ask IFAS: Manual de los Reglamentos del Agua de Florida (ufl.edu)
Mostrar más [+] Menos [-]Mejoramiento del servicio de agua potable y saneamiento en Nicaragua para la ciudad de Bluefields
2006
Produtividade e qualidade da banana prata anã, influenciada por lâminas de água, cultivada no Norte de Minas Gerais Productivity and quality of banana prata anã influenced by water depths, cultivated in the Northern Minas Gerais, Brazil Texto completo
2006
Flávio P. de Figueiredo | Everardo C. Mantovani | Antonio A. Soares | Luiz C. Costa | Márcio M. Ramos | Flávio G. Oliveira
Estudaram-se, neste trabalho, os efeitos de diferentes lâminas de irrigação sobre o crescimento vegetativo, a produtividade e qualidade da bananeira na colheita, determinando-se as variáveis básicas do manejo da irrigação para a bananeira, nos primeiro e segundo ciclos da planta, na região Norte de Minas Gerais. Os tratamentos foram de 40, 60, 80, 100 e 120% da evapotranspiração de referência (ETo) que foi estimada pela equação de Penman-Monteith. Determinaram-se o índice de área foliar e os graus-dia acumulados para cada fase fenológica, além das porcentagens de sombreamento. O tratamento correspondente à lâmina de 120% da ETo proporcionou produtividade superior à dos demais tratamentos. As lâminas de irrigação foram determinantes na qualidade dos frutos na colheita, em que o tratamento referente à lâmina de 120% da ETo, foi superior. Os tratamentos de 100 e 120% da ETo promoveram antecipação da floração e, conseqüentemente da colheita, em relação aos outros tratamentos. Os coeficientes da cultura (Kc) apresentaram, para o primeiro ciclo, os valores 0,71, 1,00 e 0,87, respectivamente, para as fases fenológicas correspondentes à II, III e IV, e de 0,97 para a fase única, referente ao segundo ciclo.<br>This study evaluated the effects of different irrigation water depths on the vegetative development, yield and quality of banana. The basic parameters of the irrigation management were determined fo a banana crop, for the first and second cycles in the Northern Minas Gerais, Brazil. The irrigation water depths applied to the treatments were 40, 60, 80, 100 and 120% of the reference evapotranspiration (ETo) estimated by Penman-Monteith equation. The leaf area index and the degrees-day accumulated for each phenological stage, as wellas the shade percentages, were determined. The results show that the treatment corresponding to 120% of the ETo provided higher productivities in comparison to other treatments. The irrigation water depths affected the fruit quality at the harvesting time, showing that the irrigation depth of 120% of the ETo was superior. The amount of water applied in treatments of 100 and 120% of the ETo in relation to the other treatments promoted earls flowering and, consequently, harvest. The crop coefficients (Kc) presented for the first cycle values of 0.71, 1.00 and 0.87 for the phenological stages corresponding to II, III and IV, respectively, and 0.97 for the only one stage for the second cycle.
Mostrar más [+] Menos [-]Estimativa da condutividade elétrica da solução do solo a partir do teor de água e da condutividade elétrica aparente do solo Estimative of soil solution electrical conductivity from soil water content and soil bulk electrical conductivity Texto completo
2006
Gessionei da S. Santana | Eugênio F. Coelho | Tibério S. M. da Silva | Márcio M. Ramos
O crescente uso da técnica de fertirrigação não tem sido acompanhado com pesquisas para disponibilizar informações capazes de proporcionar o correto manejo dessa técnica. A reflectometria no domínio do tempo (TDR) possibilita o monitoramento simultâneo e contínuo do teor de água (teta) e da condutividade elétrica aparente do solo (CEa). A literatura apresenta diversos modelos que relacionam teta e CEa com a condutividade elétrica da solução do solo (CEw), com vistas à predição da CEw a partir de dados de teta e CEa obtidos por meio da técnica da TDR. Porém, muitas pesquisas demonstram a necessidade de avaliação e calibração desses modelos para solos de diferentes classes texturais. Neste trabalho, foram avaliados seis modelos com o objetivo de conhecer a capacidade dos mesmos em relacionar teta, CEa e CEw. Experimentos de laboratório foram feitos, com solo de classes texturais franca e franco-arenosa, aplicando-se soluções com cinco condutividades elétricas combinadas com cinco teores de água no solo, resultando em 25 colunas de solo. Os modelos demonstraram capacidade para relacionar teta, CEa e CEw.<br>The increase of fertigation techniques has not been followed by researches that generate available information to guide a correct fertigation management. The time-domain reflectometry allows the simultaneously monitoring of soil water content (theta) and bulk electrical conductivity (CEa). Literature presents various models which relate TDR readings of theta and CEa to soil solution electrical conductivity (CEw). Nevertheless, many researches demonstrate the need for evaluation and calibration of these models under different soil conditions. In this work, six mathematical models were evaluated in order to establish the relationship among theta, CEa e CEw. Laboratory experiments were carried out using two soil materials, by means of applying five electrical conductivities combined with five soil water contents in PVC columns. The models allowed a reasonable relationship among theta, CEa e CEw with better performance of de RHOADES et al. (1976) e de VOGELER et al. (1996) models for the soils 1 and 2, respectively.
Mostrar más [+] Menos [-]Fertility following intracervical or intrauterine laparoscopic insemination of ewes using extenders based on coconut water | Fertilidade após a inseminação artificial intra-cervical ou laparoscópica intra-uterina de ovelhas utilizando diluidores à base de água de coco Texto completo
2006
Vanessa Porto Machado | José Ferreira Nunes | Airton Alencar de Araújo | Dimas René Perez Fernandéz | Marina Albuquerque Cordeiro | Cláudio Henrique Nogueira de Medeiros | André Luíz Nogueira de Medeiros | Alexandre Weick Uchôa Monteiro
The objetive of this study was to evaluate pregnancy rates in ewes using extenders based on coconut water (in natura: NCW or in powder: PCW-102®) following intra - cervical (Trial 1) or intrauterine laparoscopic insemination (Trial 2). Trial 1. Semen from 4 Santa Inês rams were collected, diluted at 32°C (T1: NCW; T2: PCW-102®) and cooled to 4°C. 56 adult Santa Inês ewes were inseminated intra-cervically following syncronization, 31 using the extender NCW and 25 the extender PCW-102®. Trial 2. Semen from 5 rams (Santa Inês: n=04; Dorper n=01) were collected and processed as described. 64 adult crossbred multiparous ewes were inseminated intrauterine by laparoscopy following oestrus syncronization. 37 ewes using the extender NCW and 27 the extender PCW-102®. The pregnancy diagnosis was performed by ultrasonography. The fertility rates between treatments for each method of insemination and within each extender for both methods were analysed by Chi-square test (p<0,05). The pregnancy rates following intra-cervical (NCW: 25.8% vs PCW-102®: 48%) and intrauterine (NCW: 72.9% vs 70.3%) inseminations were not influenced by the extenders. The pregnancy rate was influenced by insemination method (intra-cervical: 35.7% vs laparoscopy: 71.8%; p<0,05). The extenders based coconut water as basis can be used following cervical or intra-uterine laparoscopic inseminations in ewes from Northeast of Brazil under field conditions. | O objetivo deste estudo foi avaliar a taxa de prenhez em ovelhas utilizando diluidores à base de água de coco (in natura: ACN ou em pó: ACP-102®) após inseminação artificial intra-cervical (Experimento 1) ou laparoscópica intra-uterina (Experimento 2). Experimento 1. Sêmen de 4 carneiros Santa Inês foi coletado, diluído a 37°C (T1: ACN; T2: ACP-102®) e resfriado á 4°C. 56 ovelhas Santa Inês foram inseminadas cervicalmente após a sincronização, 31 utilizando o diluidor ACN e 25 o diluidor ACP-102®. Experimento 2. Sêmen de 5 carneiros adultos (Santa Inês: n=04; Dorper n=01) foi coletado e processado de acordo com o descrito. 64 ovelhas SRD foram inseminadas intra-uterina por laparoscopia após a sincronização do estro, 37 utilizando o diluidor ACN e 27 o diluidor ACP-102®. O diagnóstico de gestação foi realizado por ultra-sonografia. A taxa de prenhez entre os tratamentos, dentro de cada método de inseminação, entre cada diluidor para ambos métodos de inseminação foi analisada pelo teste do Qui-quadrado (p<0,05). A taxa de prenhez após IA intra-cervical (ACN: 25,8% vs. ACP-102®: 48%) e laparoscópica (ACN: 72,9% vs ACP-102®: 70,3%) não foi influenciada pelos diluidores. A taxa de prenhez foi influenciada pelo método de inseminação (intra-cervical: 35,7% vs. laparoscopia: 71,8%; p<0,05). Os diluidores a base de água de coco podem ser utilizados nas inseminações artificiais cervical ou laparoscopica em ovelhas do Nordeste do Brasil em condições de campo.
Mostrar más [+] Menos [-]Comparison between powder coconut water (ACP®) and Tris as extenders for canine semen cryopreservation | Comparação entre a água de coco em pó (ACP®) e o Tris como diluidores na criopreservação do sêmen de cães Texto completo
2006
Alexandre Rodrigues Silva | Rita de Cássia Soares Cardoso | Lúcia Daniel Machado da Silva
The present study compared powder coconut water (ACP®) and Tris extenders on canine semen cryopreservation by classic evaluation and thermoresistance test. Five stud dogs were submitted to two semen collections by digital manipulation. Sperm fractions were analyzed regarding to its color, volume, sperm concentration, motility, vigor and morphology. Semen samples were divided into two aliquots: the first one was extended in Tris and second one in ACP®. Both extenders contained 20% egg yolk. Samples were cooled to 5ºC, glycerol added (6%), packaged in 0.25mL straws, frozen in nitrogen vapors and finally stored in liquid nitrogen. One week later, thaw was performed at 38ºC per 1min in water bath and new evaluations of sperm motility, vigor and morphology were conducted. Samples were kept at 38ºC in water bath and evaluated at 15 and 30min after thaw. No significant difference was observed between extenders throughout cryopreservation or thawing procedures, as well as during thermoresistance test, concerning to characteristics evaluated. Tris and ACP® were efficient in conserving 50% mobile spermatozoa and 70% morphologically normal sperm after thaw. Thus, ACP® can be used as an alternative extender for canine semen cryopreservation. | O presente trabalho comparou a água de coco em pó (ACP®) com o diluidor Tris na criopreservação do sêmen canino através da avaliação clássica e do teste de termorresistência. Cinco reprodutores caninos foram submetidos a duas coletas de sêmen através de manipulação digital. As frações espermáticas foram avaliadas quanto à sua coloração, volume, concentração, motilidade, vigor e morfologia espermática. As amostras de sêmen foram divididas em duas alíquotas: a primeira foi diluída em Tris e a segunda em ACP®. Ambos os diluidores continham 20% de gema de ovo. As amostras foram refrigeradas, adicionadas de glicerol (6%), envasadas em palhetas de 0,25mL, criopreservadas em vapores de nitrogênio, e finalmente armazenadas em nitrogênio líquido. Após uma semana, foi realizada a descongelação a 38ºC por 1min em banho-maria, sendo realizadas novas avaliações de motilidade, vigor e morfologia espermática. As amostras foram mantidas a 38ºC no banho-maria e avaliadas aos 15 e 30 min após descongelação. Não foram observadas diferenças significativas entre os dois diluidores no decorrer dos procedimentos de criopreservação e descongelação, bem como durante o teste de termorresistência, em relação às características avaliadas. O Tris e o ACP® foram eficientes em conservar 50% de espermatozóides móveis e 70% de espermatozóides morfologicamente normais após a descongelação. Assim, o ACP® pode ser utilizado como diluidor alternativo para a criopreservação do sêmen canino.
Mostrar más [+] Menos [-]Avances en técnicas de medición de la velocidad del agua subterránea para la remediación de contaminaciones Texto completo
2006
Guaraglia, Dardo Oscar | Mayosky, Miguel Angel
Sumario: Motivación y estructura de la tesis; Presentación del problema; Revisión de métodos para la medición de velocidades de fluídos; Estudio de métodos térmicos para su aplicación a la medición de la velocidad del agua subterránea; Validación del modelo eléctrico; Propuesta de un nuevo método térmico; Conclusiones y futuras líneas de investigación; Apéndices | Doctor en Ingeniería | Universidad Nacional de La Plata | Facultad de Ingeniería
Mostrar más [+] Menos [-]La valorización del agua y los servicios ambientales: una lectura critica de los modelos conceptuales vigentes
2006
Bustamante, R.R. | Durán, A.