Detection of phthalate esters in seawater by stir bar sorptive extraction and gas chromatography–mass spectrometry
2016
Si, Qingqing | Li, Fengmin | Gao, Chenchen | Wang, Cong | Wang, Zhenyu | Zhao, Jian
We developed the stir bar sorptive extraction (SBSE)–gas chromatography–mass spectrometry (GC–MS) method to detect 15 kinds of PAEs in seawater. The stir bars (20mm in length and 1mm in film thickness) coated with 150μL of polydimethylsiloxane (PDMS) were found to demonstrate the optimal extraction of PAEs. The optimal conditions were as follows: extraction time of 2h, extraction temperature of 25°C, sodium chloride of 5%, methanol of 10%, analytical time of 50min, and methanol–acetonitrile (4:1) as the solvent. SBSE–GC–MS revealed that under the set temperature, the chromatographic peaks of all 15 PAEs can appear with complete separation. The detection limit ranged from 0.07μg/L to 5.71μg/L, whereas the limit of quantification ranged from 0.023μg/L to 193μg/L, and the correlation coefficients between the chromatographic peak area and concentration of the PAEs were greater than 0.92.
Показать больше [+] Меньше [-]Ключевые слова АГРОВОК
Библиографическая информация
Эту запись предоставил National Agricultural Library