A Simple and Accurate Method to Measure Total Gaseous Mercury Concentrations in Unsaturated Soils
2011
Moore, Chris (Christopher W.) | Castro, Mark S. | Brooks, Steven B.
The goal of this project was to develop a method to measure the total gaseous mercury (TGM) concentrations in unsaturated soils. Existing methods did not allow for easy replication, were costly, and were more suited for other gases, such as CO2, that do not react with collection surfaces. To overcome these problems, we developed a method that simultaneously collects up to ten soil pore air samples. We used a single mass flow controller, one pump, and two banks of rotameters to draw soil air out of the ground at 25 smL min−1 onto gold-coated quartz traps. Analysis of the gold traps was performed with a Tekran 2500 CVAFS mercury detector. The system was field tested at the Piney Reservoir Ambient Air Monitoring Station in western Maryland. Our system was relatively precise and accurate. For example, replicate TGM concentrations differed by less than 25% and recovery of known amounts of mercury were greater than 95%. Field measurements showed that the maximum soil pore air TGM concentrations, between 3 and 4 ng m−3, occurred at the Oe–A soil horizon interface. At all other depths, the total mercury concentrations were lower than the ambient air concentrations of 1.8 ng m−3. We believe our new method can be used to precisely and accurately measure the TGM concentrations in unsaturated soils at multiple locations simultaneously.
Показать больше [+] Меньше [-]Ключевые слова АГРОВОК
Библиографическая информация
Эту запись предоставил National Agricultural Library