Measurement of aerosol nanoparticles from a combustion particle generator by using three types of dilutors
2016
Lee, Byung Uk | Bae, Gwi Nam
Ultrafine aerosol nanoparticles created from combustion were measured by using three types of dilutors: a simple mixing dilutor, an ejector dilutor, and a rotational disk dilutor. The original particle size distribution from combustion was compared to the estimated distribution from these dilutors. The results showed that ultrafine aerosol nanoparticles maintained their particle size distribution, while particle concentrations decreased 10–20 fold in the dilution processes. Therefore, the dilutors not only diluted the aerosol nanoparticle concentration to the level of the measurement devices, but also helped estimate the shape of aerosol particle size distribution, particularly for ultrafine aerosol nanoparticles from combustion.