Уточнить поиск
Результаты 1-3 из 3
Evaluation of a Solar Water Distiller Coupled with Solar Evacuated Tubes
2022
Eldehn, Israa | Mustafa, Mubarak | Atia, Mohamed | Salama, Mohamed | Galal, Yehia | Hussein, Mohamed
The scarcity of fresh water is a primary problem in remote regions. Thus, an economical and related water distillation solar still coupled with a solar collector was designed and studied experimentally. This study aims to investigate and evaluate the performance of an active single-slope solar still (ASSSS) coupled with a solar evacuated tube collector (ETC) as the water heater. The results showed that the average distillate productivity of ASSSS combined with U pipe solar (ETC) was 1.085 l/m2 in December 2020, but 3.12 l/m2 in August 2021. These quantities of the water distiller were higher than those of a passive solar distiller with a single slope (PSSSS). The average value of the water temperature increased using the ASSSS coupled with ETC in August 2021 at 79.1°C, whereas it was 71°C in August 2021 for PSSSS. These results indicate that the ASSSS is more effective than the PSSSS.
Показать больше [+] Меньше [-]Evaluation of a Solar Water Distiller Coupled with Solar Evacuated Tubes
2022
Israa Eldehn | Mubarak Mustafa | Mohamed Atia | Mohamed Salama | Yehia Galal | Mohamed Hussein
The scarcity of fresh water is a primary problem in remote regions. Thus, an economical and related water distillation solar still coupled with a solar collector was designed and studied experimentally. This study aims to investigate and evaluate the performance of an active single-slope solar still (ASSSS) coupled with a solar evacuated tube collector (ETC) as the water heater. The results showed that the average distillate productivity of ASSSS combined with U pipe solar (ETC) was 1.085 l/m2 in December 2020, but 3.12 l/m2 in August 2021. These quantities of the water distiller were higher than those of a passive solar distiller with a single slope (PSSSS). The average value of the water temperature increased using the ASSSS coupled with ETC in August 2021 at 79.1°C, whereas it was 71°C in August 2021 for PSSSS. These results indicate that the ASSSS is more effective than the PSSSS.
Показать больше [+] Меньше [-]EVALUATION OF SOLAR POWERED DRIP IRRIGATION SYSTEM SYSTEM
2019
Norhan Sadek | عبد الغني محمد الجندي | Ahmed Hegazi | Osma Beder
Egypt’s demand for electricity is growing rapidly and the need to develop alternative power resources is becoming ever more urgent. It is estimated that demand is increasing at a rate of 1,500 to 2,000 MW a year as a result of rapid urbanization and economic growth. Egypt is now struggling to meet its own energy needs. Egypt has been suffering severe power shortages and rolling blackouts over the past years, necessitating the requirement to look to alternative energy options. Energy demand is increasing fastly so as to meet the requirements of growing population in the world. This study aimed to compare between traditional energy and solar generators in terms of energy consumption and cost effectiveness. Pumping systems were used to operate units of drip irrigation for the crop which was planted, so as to determine the best and least expensive energy consumption under this system. The required hydraulic experiment and measurements were performed on a private farm at Beni Salama, Giza which lies at latitude 30.32°N, 30.80°E during 2016 and 2017. Measurements were done at two days randomly selected in the months of December and March. This study evaluated the average monthly measurements for December 2016 and March 2017 where onions were grown. Maximum and minimum for Pv system DC power output were 6398 and 5755 W, the maximum and minimum for AC current were 5814 and 5548 W, respectively. Maximum and minimum for hydraulic power were 5911 and 3553 W, respectively. Efficiency of both photovoltaic, inverter, pump and overall system were also calculated for these days. Maximum and minimum for module efficiency were 14% and 13.2%, respectively, and maximum and minimum for inverter efficiency were 95%, 89%, respectively. Maximum and minimum for pump efficiency were 64%, 54%, respectively. While for overall efficiency, they were 8% and 3%, respectively. The results showed that solar pumping system is a reliable system
Показать больше [+] Меньше [-]