Уточнить поиск
Результаты 1-10 из 30
Effects of abdominal insufflation with nitrous oxide on cardiorespiratory measurements in spontaneously breathing isoflurane-anesthetized dogs.
1993
Gross M.E. | Jones B.D. | Bergstresser D.R. | Rosenhauer R.R.
Cardiorespiratory effects of abdominal insufflation were evaluated in 8 dogs during isoflurane anesthesia. Each dog was studied 3 times, in 1 of the following orders of insufflation pressures: 10-20-30, 20-30-10, 30-20-10, 10-30-20, 20-10-30, and 30-10-20 mm of Hg. Anesthesia was induced by use of a mask, dogs were intubated, and anesthesia was maintained by isoflurane in 100% oxygen. After instrumentation, baseline values were recorded (time 0), and the abdomen was insufflated with nitrous oxide. Data were recorded at 5, 10, 15, 20, 25, and 30 minutes after insufflation. The abdomen was then desufflated, with recording of data continuing at 35 and 40 minutes. Mean arterial pressure increased at 5 minutes during 20 mm of Hg insufflation pressure, and from 20 to 30 minutes during 30 mm of Hg pressure. Tidal volume decreased from 5 to 30 minutes during 10 and 20 mm of Hg pressures, and from 5 to 40 minutes during 30 mm of Hg pressure. Minute ventilation decreased at 10 and 20 minutes during 20 mm of Hg pressure. End-tidal CO2 concentration increased from 5 to 30 minutes during 20 and 30 mm of Hg pressure. The PaCO2 decreased at 40 minutes during 10 mm of Hg pressure, at 30 minutes during 20 mm of Hg pressure, and from 10 to 40 minutes during 30 mm of Hg pressure. Values for pH decreased from 10 to 30 minutes during 20 and 30 mm of Hg pressures. The PaO2 decreased from 20 to 40 minutes during 10 mm of Hg pressure, at 30 minutes during 20 mm of Hg pressure, and from 10 to 40 minutes during 30 mm of Hg pressure. Percentage decrease in tidal volume was greater at 5 and 15 minutes with 30 mm of Hg pressure. Differences in percentage increase in end tidal CO2 concentration were observed among the 3 pressures from 5 to 30 minutes. Although significant, these changes do not preclude use of laparoscopy if insufflation pressure > 20 mm of Hg is avoided.
Показать больше [+] Меньше [-]Normal laparoscopic anatomy of the bovine abdomen.
1993
Anderson D.E. | Gaughan E.M. | St Jean G.
Three laparoscopic procedures were performed on each of 6 adult jersey cows in the first trimester of gestation to describe normal laparoscopic anatomy of the bovine abdomen. Also, a technique for laparoscopy of the cranioventral portion of the abdomen was described. Right paralumbar fossa, left paralumbar fossa, and cranioventral midline laparoscopy were performed 72 hours apart on each cow. Physical examination findings, CBC, serum biochemical analysis, and peritoneal fluid analysis before and 72 hours after the first surgery were used to assess the effects of the procedures on the cows. Exploratory celiotomy was performed 2 weeks after the last laparoscopy. The cows were then reexamined 6 weeks after the last procedure. The t-test for paired data was used for statistical analysis; the level of significance was P < 0.05. Laparoscopy was performed without complication in all cows. Adverse effects of laparoscopy, individually or serially, were not observed. Significant differences were not found between CBC, serum biochemical, and peritoneal fluid variables taken before and 72 hours after surgery.
Показать больше [+] Меньше [-]Laparoscopic anatomy of the abdomen in dorsally recumbent horses.
1996
Galuppo L.D. | Snyder J.R. | Pascoe J.R. | Stover S.M. | Morgan R.
Comparison of peritoneal fluid analysis before and after exploratory celiotomy and omentopexy in cattle.
1994
Anderson D.E. | Cornwell D. | St Jean G. | Desrochers A. | Anderson L.S.
The effect of right paralumbar fossa exploratory celiotomy and omentopexy on peritoneal fluid constituents was studied in 22 adult dairy cows. Six cows were eliminated on the basis of physical examination findings (n = 2), surgical findings (n = 2), or inability to obtain a sufficient volume of peritoneal fluid (n = 2). Sixteen cattle had normal results of Csc and serum biochemical analysis, and a minimum of 1 ml of peritoneal fluid was obtained by abdominocentesis. Abdominocentesis was repeated on days 1, 2, and 6 after surgery. Statistical analysis for repeated measures was performed, using a significance level of P < 0.05. Stage of gestation was evaluated for interaction with time. Mean total nucleated cell count was 3,200 cells/1 before surgery, was significantly increased 2 days after surgery (16,336 cells/microliter), and continued to increase through day 6 (20,542 cells/microliter). Mean polymorphonuclear cell count was 1,312 cells/microliter before surgery and was significantly higher at 2 (11,043 cells/microliter) and 6 (10,619 cells/microliter) days after surgery. Mean lymphocyte count was 254 cells/microliter before surgery and was significantly increased 2 days (1,911 cells/microliter) after surgery. By day 6, lymphocyte numbers were similar to preoperative values. Mean mononuclear cell count was 770 cells/microliter before surgery and was significantly increased on days 1 (3,084 cells/microliter), 2 (3,285 cells/microliter and 6 (2,349 cells/microliter) after surgery. Mean eosinophil numbers were 1,388 cells/microliter before surgery and were significantly increased on day 6 (6,347 cells/microliter) only. Interaction between time and stage of gestation was found only for specific gravity and total protein concentration. In general, specific gravity and total protein concentration increased after surgery (mean before surgery, 1.016 and 3.6 g/dl; mean after surgery, 1.021 and 5.6 g/dl).
Показать больше [+] Меньше [-]Evaluation of jejunal microvasculature of healthy anesthetized dogs with sidestream dark field video microscopy Полный текст
2020
OBJECTIVE To determine the feasibility of sidestream dark field (SDF) video microscopy for the evaluation of the jejunal microvasculature of healthy dogs. ANIMALS 30 healthy sexually intact female shelter dogs anesthetized for ovariohysterectomy. PROCEDURES Preoperative physical and clinicopathologic assessments were performed to confirm health status. Then healthy dogs were anesthetized, and the abdomen was incised at the ventral midline for ovariohysterectomy and jejunal microvasculature evaluation. An SDF video microscope imaged the microvasculature of 2 sites of a portion of the jejunum, and recorded videos were analyzed with software capable of quantitating parameters of microvascular health. Macrovascular parameters (heart rate, respiratory rate, and hemoglobin oxygen saturation) were also recorded during anesthesia. RESULTS Quantified jejunal microvascular parameters included valid microvascular density (mean ± SD, 251.72 ± 97.10 μm/mm), RBC-filling percentage (66.96 ± 8.00%), RBC column width (7.11 ± 0.72 μm), and perfused boundary region (2.17 ± 0.42 μm). The perfused boundary region and RBC-filling percentage had a significant negative correlation. Strong to weak positive correlations were noted among the perfused boundary regions of small-, medium-, and large-sized microvessels. No significant correlations were identified between microvascular parameters and age, body weight, preoperative clinicopathologic results, or macrovascular parameters. CONCLUSIONS AND CLINICAL RELEVANCE Interrogation of the jejunal microvasculature of healthy dogs with SDF video microscopy was feasible. Results of this study indicated that SDF video microscopy is worth additional investigation, including interrogation of diseased small intestine in dogs.
Показать больше [+] Меньше [-]Diffusion-weighted and perfusion-weighted magnetic resonance imaging of the prostate gland of healthy adult dogs Полный текст
2019
Willmitzer, Florian | Del Chicca, Francesca | Kircher, Patrick R. | Wang-Leandro, Adriano | Kronen, Peter W. | Verdino, Dagmar | Rufenacht, Daniel | Porcellini, Beat | Richter, Henning
OBJECTIVE To describe diffusion and perfusion characteristics of the prostate gland of healthy sexually intact adult dogs as determined by use of diffusion-weighted and perfusion-weighted MRI. ANIMALS 12 healthy sexually intact adult Beagles. PROCEDURES Ultrasonography of the prostate gland was performed. Subsequently, each dog was anesthetized, and morphological, diffusion-weighted, and perfusion-weighted MRI of the caudal aspect of the abdomen was performed. The apparent diffusion coefficient was calculated for the prostate gland parenchyma in diffusion-weighted MRI images in the central ventral and peripheral dorsal areas. Perfusion variables were examined in multiple regions of interest (ROIs) in the ventral and dorsal areas of the prostate gland and in the gluteal musculature. Signal intensity was determined, and a time-intensity curve was generated for each ROI. RESULTS Results of ultrasonographic examination of the prostate gland revealed no abnormalities for any dog. Median apparent diffusion coefficient of the prostate gland was 1.51 × 10-3 mm2/s (range, 1.04 × 10-3 mm2/s to 1.86 × 10-3 mm2/s). Perfusion-weighted MRI variables for the ROIs differed between the prostate gland parenchyma and gluteal musculature. CONCLUSIONS AND CLINICAL RELEVANCE Results provided baseline information about diffusion and perfusion characteristics of the prostate gland in healthy sexually intact adult dogs. Additional studies with dogs of various ages and breeds, with and without abnormalities of the prostate gland, will be necessary to validate these findings and investigate clinical applications.
Показать больше [+] Меньше [-]Perfusion-weighted and diffusion-weighted magnetic resonance imaging of the liver, spleen, and kidneys of healthy adult male cats Полный текст
2019
Del Chicca, Francesca | Salesov, Elena | Joerger, Fabiola | Richter, Henning | Reusch, Claudia E. | Kircher, Patrick R.
OBJECTIVE To describe perfusion and diffusion characteristics of the liver, spleen, and kidneys of healthy adult male cats as determined by morphological, perfusion-weighted, and diffusion-weighted MRI. ANIMALS 12 healthy adult male cats. PROCEDURES Each cat was anesthetized. Morphological, perfusion-weighted, and diffusion-weighted MRI of the cranial aspect of the abdomen was performed. A region of interest (ROI) was established on MRI images for each of the following structures: liver, spleen, cortex and medulla of both kidneys, and skeletal muscle. Signal intensity was determined, and a time-intensity curve was generated for each ROI. The apparent diffusion coefficient (ADC) was calculated for the hepatic and splenic parenchyma and kidneys on diffusion-weighted MRI images. The normalized ADC for the liver was calculated as the ratio of the ADC for the hepatic parenchyma to the ADC for the splenic parenchyma. RESULTS Perfusion-weighted MRI variables differed among the 5 ROIs. Median ADC of the hepatic parenchyma was 1.38 × 10(-3) mm2/s, and mean ± SD normalized ADC for the liver was 1.86 ± 0.18. Median ADC of the renal cortex and renal medulla was 1.65 × 10(-3) mm2/s and 1.93 × 10(-3) mm2/s, respectively. CONCLUSIONS AND CLINICAL RELEVANCE Results provided preliminary baseline information about the diffusion and perfusion characteristics of structures in the cranial aspect of the abdomen of healthy adult male cats. Additional studies of cats of different sex and age groups as well as with and without cranial abdominal pathological conditions are necessary to validate and refine these findings.
Показать больше [+] Меньше [-]Perfusion- and diffusion-weighted magnetic resonance imaging of the liver of healthy dogs Полный текст
2016
Del Chicca, Francesca | Schwarz, Andrea | Grest, Paula | Kircher, Patrick R.
OBJECTIVE To describe the perfusion and diffusion characteristics of the liver in healthy dogs as determined by morphological, perfusion-weighted, and diffusion-weighted MRI. ANIMALS 11 healthy adult Beagles. PROCEDURES Each dog was anesthetized and underwent morphological, perfusion-weighted, and diffusion-weighted MRI of the cranial aspect of the abdomen. On the MRI images, a region of interest (ROI) was established for each of 6 structures (aorta, caudal vena cava, portal vein, hepatic parenchyma, splenic parenchyma, and skeletal [epaxial] muscle). The signal intensity was determined, and a time-intensity curve was generated for each ROI. The apparent diffusion coefficient (ADC) was calculated for the hepatic and splenic parenchyma in diffusion-weighted MRI images, and the normalized ADC for the liver was calculated as the ratio of the ADC for the hepatic parenchyma to the ADC for the splenic parenchyma. Dogs also underwent abdominal ultrasonography, and ultrasound-guided fine-needle aspirate samples and biopsy specimens were obtained from the liver for cytologic and histologic examination. RESULTS Cytologic and histologic results suggested that the liver was clinically normal in all dogs. Perfusion-weighted MRI parameters varied among the 6 ROIs. The mean ± SD ADC of the hepatic parenchyma was 0.84 × 10(−3) mm2/s ± 0.17 × 10(−3) mm2/s, and the mean normalized ADC for the liver was 1.8 ± 0.4. CONCLUSIONS AND CLINICAL RELEVANCE Results provided preliminary baseline information about the diffusion and perfusion characteristics of the liver in healthy dogs. Additional studies on dogs of various breeds with and without hepatopathies are necessary to validate and refine these findings.
Показать больше [+] Меньше [-]Effect of body position on intra-abdominal pressures and abdominal perfusion pressures measured at three sites in horses anesthetized with short-term total intravenous anesthesia Полный текст
2014
Scott, Victoria H. | Williams, Jarred M. | Mudge, Margaret C. | Hurcombe, Samuel D.
Objective-To assess effects of body position on direct measurements of intra-abdominal pressure (IAP) and abdominal perfusion pressure (APP) in horses anesthetized with total intravenous anesthesia (TIVA). Animals-9 healthy adult horses. Procedures-Instrumentation in unsedated standing horses involved insertion of an arterial catheter for blood pressure measurements and 3 intraperitoneal cannulas (left flank, right flank, and ventral abdomen) for IAP measurements. Baseline values were measured for heart rate, respiratory rate, systolic arterial blood pressure, mean arterial blood pressure (MAP), diastolic arterial blood pressure, and IAP. Horses were medicated with xylazine, and pressures were measured again. Anesthesia was induced with ketamine-diazepam and maintained with a ketamine-guaifenesin infusion. Horses were positioned twice into left lateral recumbency, right lateral recumbency, or dorsal recumbency. Hemodynamic pressures and accessible abdominal pressures were measured for each recumbency position. The APP was calculated as MAP - IAP. Differences in IAP, MAP, APP and sedation (standing horses) or body position (anesthetized horses) were compared by means of repeated-measures ANOVA or paired t tests. Results-Baseline hemodynamic and IAPs were not different after xylazine administration. Ventral abdomen IAP and MAP were lower for horses in dorsal recumbency than in right or left lateral recumbency. Ventral abdomen APP remained unchanged. For lateral recumbencies, flank IAP was lower and APP was higher than pressure measurements at the same sites during dorsal recumbency. Conclusions and Clinical Relevance-Body position affected IAP and APP in healthy anesthetized horses. These effects should be considered when developing IAP acquisition methods for use in horses with abdominal disease.
Показать больше [+] Меньше [-]Abdominal anatomic features and reference values determined by use of ultrasonography in healthy common rats (Rattus norvegicus) Полный текст
2014
Banzato, Tommaso | Bellini, Luca | Contiero, Barbara | Martin, Andrea | Balikçi, Sema | Zotti, Alessandro
Objective-To determine ultrasonographic features and reference values of the anatomy of the abdomen of common rats (Rattus norvegicus). Animals-20 adult male and 20 adult female rats. Procedures-A complete abdominal ultrasonographic examination was performed with the rats sedated. The cadavers of 4 rats were used for anatomic comparisons. Two cadavers were dissected and 2 cadavers were frozen and then cross-sectioned by use of an electric bandsaw. Slices were cleaned with water and photographed on each side. Correlations between variables were determined. Results-The ultrasonographic anatomy of the abdomen was determined, including measurements of the kidneys and adrenal glands and thickness of the walls of the stomach (saccus caecus, fundus, and pylorus), duodenum, and cecum. A significant positive correlation between kidney size and body weight was detected. The dorsoventral measurements of the left and right adrenal gland were significantly different, regardless of sex. Dorsoventral measurements of the right adrenal gland were significantly different between males and females. Conclusions and Clinical Relevance-The ultrasonographic images and data provided an atlas of the ultrasonographic anatomy of common rats that may be useful to veterinary radiologists, clinicians, and researchers.
Показать больше [+] Меньше [-]