Уточнить поиск
Результаты 1-7 из 7
Assessment of vertebral canal diameter and bony malformations of the cervical part of the spine in horses with cervical stenotic myelopathy
1994
Moore, B.R. | Reed, S.M. | Biller, D.S. | Kohn, C.W. | Weisbrode, S.E.
Magnification of cervical radiographs prevents accurate interpretation of vertebral canal absolute minimum sagittal diameter (MSD) values and application of the established MSD values for diagnosis of cervical stenotic myelopathy (CSM). Variability in MSD determination in human beings, owing to radiographic magnification, is minimized by assessing a ratio of the vertebral canal diameter to the sagittal width of the vertebral body. This relative measurement technique improves the accuracy of diagnosis of cervical spinal stenosis in human beings. The MSD of the vertebral canal was determined in 50 horses with CSM and 50 control horses, using a radiopaque marker method for correction of magnification. In addition, a ratio of the absolute MSD to the sagittal width of the vertebral body and a ratio of the absolute MSD to the length of the vertebral body were determined in 100 CSM-affected and 100 control horses. Response operating characteristic curve analysis of each method determined that the sagittal ratio method of canal diameter assessment provided the most accurate interpretation of cervical radiographs for diagnosis of CSM, with sensitivity and specificity of larger than or equal to 89% at each vertebral site. The accuracy of the ratio method, without consideration of bony malformation, supports the importance, and perhaps prerequisite, of generalized vertebral canal stenosis in the pathogenesis of CSM. Subjective evaluation of bony malformations from cervical radiographs of 100 CSM-affected horses and 100 control horses indicated that CSM-affected horses have more severe bony malformation than do control horses. However, moderate to marked degenerative joint disease of the articular processes was frequently observed in control horses. Subjective evaluation of bony malformation does not distinguish between CSM-affected and unaffected horses.
Показать больше [+] Меньше [-]Comparison of measured and calculated values for colloid osmotic pressure in hospitalized animals
1994
Brown, S.A. | Dusza, K. | Boehmer, J.
A relation exists between colloid osmotic pressure and serum total protein concentration; equations describing this relation have been used to determine a calculated value for colloid osmotic pressure. However, the relation between total protein concentration and colloid osmotic pressure is altered by the method used to measure protein and by changes in the ratio of concentrations of albumin (A) to globulin (G). We developed nomograms for estimating colloid osmotic pressure from A and G concentrations, using samples obtained from clinically normal animals and compared the accuracy of these nomograms with that of previously described equations relating colloid osmotic pressure to total protein concentration. For comparison, serum samples from canine (n = 106), equine (n = 79), feline (n = 24), and bovine (n = 27) patients admitted to the University of Georgia Veterinary Medical Teaching Hospital were used. Results indicated that nomograms based on protein concentration estimated by a refractometer generally were the least reliable. Although predictive nomograms, using total protein concentration determined by the biuret method, provided better results for serum samples, there was considerable variation between measured and calculated values for colloid osmotic pressure in all species studied. Calculated values for colloid osmotic pressure derived from A and G concentrations were most closely related to measured values for colloid osmotic pressure in dogs, horses, and cats. However, calculated values for colloid osmotic pressure differed from measured values by as much as 5 mm of Hg for some samples by each of the methods of estimation. These results indicate that, although calculated values for colloid osmotic pressure may be most accurate when variations in the A-to-G ratio are accounted for in the nomogram, none of the calculation methods provided a consistently accurate estimate of colloid osmotic pressure. For clinical patients, colloid osmotic pressure based on these nomograms cannot replace direct measurement.
Показать больше [+] Меньше [-]Reliability of single urine and serum samples for estimation of 24-hour urinary uric acid excretion in six healthy Beagles
1994
Bartges, J.W. | Osborne, C.A. | Felice, L.J. | Unger, L.K. | Bird, K.A. | Koehler, L.A. | Chen, M.
Urine uric acid-to-urine creatinine ratios (UUA:UC), urine uric acid concentrations, urine uric acid concentrations corrected for glomerular filtration rate, and urinary uric acid fractional excretions were compared with 24-hour urinary uric acid excretions measured in 6 healthy adult female Beagles. Comparisons, using correlation analysis, were made when dogs consumed a 10.4% protein (dry weight), casein-based diet and a 31.4% protein (dry weight), meat-based diet. The UUA:UC, urine uric acid concentrations corrected for glomerular filtration rate, and urinary uric acid fractional excretions were not reliable estimates of 24-hour urinary uric acid excretions during consumption of either diet. Urine uric acid concentrations in samples collected 2, 4, 6, and 24 hours after initiation of collection correlated with 24-hour urinary uric acid excretions when dogs consumed the casein-based diet; correlation was not found at any time interval when dogs consumed the meat-based diet. Therefore, determination of 24-hour urinary uric acid excretion is recommended because UUA:UC are unreliable.
Показать больше [+] Меньше [-]Evaluation of quantitative acid-base balance and determination of unidentified anions in swine
1994
Frischmeryer, K.J. | Moon, P.F.
Arterial blood samples were collected from 19 anesthetized pigs before and after hemorrhage was induced. Blood gas tensions and concentrations of sodium, potassium, chloride, lactate, and total protein were measured. Results indicated that hydrogen ion (H+) concentration calculated from a specific formula was a biased and imprecise estimate of measured H+ concentration. The bias was 5.45 nEq/L, with limits of agreement from -7.92 to 18.83 nEq/L. Because albumin is the fraction of plasma protein most important in acid-base balance, the agreement between predicted and measured H+ concentration was reevaluated, using an albumin charge estimate and a reference swine albumin-to-globulin ratio. This improved the ability of the formula to predict H+ concentration; the bias decreased to 1.33 nEq/L with limits of agreement from -12.16 to 9.49 nEq/L. The formula and a simplified approach for clinical application were biased and unacceptably imprecise estimators of lactate (L-) concentration. The formula approach underestimated L- concentration by 2.8 (-12.4, 6.7) mEq/L, whereas the simplified method overestimated L- concentration by 5.0 (-3.8, 13.9) mEq/L.
Показать больше [+] Меньше [-]Dual-energy X-ray absorptiometry of canine femurs with and without fracture fixation devices
1994
Markel, M.D. | Bogdanske, J.J.
The effect of 5 fracture fixation methods on bone mineral density (BMD) measurement of femurs, using dual-energy X-ray absorptiometry (DXA) was determined in a canine model. Six regions of interest were measured, including the entire femur, the diaphysis of the femur, and small regions centered over the middiaphysis of the bone (lateral middiaphyseal cortex, medial middiaphyseal cortex, middiaphyseal medullary canal, and total middiaphysis). Eight unpaired femurs were collected and scanned by use of DXA before (5 separate scans/femur) and after (5 separate scans/femur) fixation by use of 1 of 5 fixation methods. These fixation methods included: intramedullary (IM) nail: IM nail and cerclage wires; IM nail and external skeletal fixation.; locked IM nail; and a dynamic compression plate (DCP). All implants were made of stainless steel. The IM nail fixation devices caused significant decreases in the DXA measurement of BMD in the small regions of interest, compared with femurs without fixation devices (mean decrease, 37.3%; P < 0.05). The locked nail caused similar, but larger, decreases in the DXA measurement of BMD, compared with the IM nail fixation methods (P < 0.05). Plate fixation caused a small, but significant (P < 0.05), decrease (2.8%) in the DXA measurement of BMD in the large regions of interest, but when all regions were averaged, it did not cause significant change in this measurement, compared with femurs without fixation devices. Plate fixation caused a large change in the DXA measurement of BMD in 1 region only in the lateral cortical bone under the plate where the DXA measurement of BMD was increased 13.3% over that in femurs without fixation devices (P < 0.05). In femurs without fixation devices, the precision error ranged from 0.5% for large regions of interest to 2.4% for small regions of interest. None of the fixation methods altered the precision error of large regions of interest (P > 0.05). In contrast, the precision errors of the small regions of interest were increased by the IM fixation methods and the locked IM nail, When all regions were combined, IM fixation methods caused significant (P < 0.05) increase in the precision error, compared with femurs without fixation devices (mean increase, 157%; range, 121 to 193%). Plate fixation did not change the precision error of any region of interest, compared with femurs without fixation devices (P > 0.05; power = 0.8 at delta = 64%).
Показать больше [+] Меньше [-]Repeatability and normal values for measurement of pharyngeal and tracheal pressures in exercising horses
1994
Ducharme, N.G. | Hackett, R.P. | Ainsworth, D.M. | Erb, H.N. | Shannon, K.J.
Repeatability of measurements of peak and mean tracheal and pharyngeal pressures in exercising horses was determined. Five athletically fit horses were subjected to repeated (n = 5) standardized exercise trials. Static pressures in the trachea, nasopharynx, and mask were determined. At least 96% of all mean pressure measurements were within 5 cm of H2O of the mean value for any horse. Peak pressure measurements were less repeatable, but at least 96% of all measurements were within 10 cm of the mean peak measurements for any horse. In 10 horses galloping at 14 m/s, the 95% confidence interval for peak tracheal and pharyngeal inspiratory pressures ranged from -40 to -50 cm of H2O and -20 to -26 cm of H2O, respectively. During expiration, the 95% confidence interval for peak tracheal and pharyngeal pressure at the same speed ranged from 15 to 28 cm of H2O and 10 to 24 cm of H2O respectively. During inspiration, horses with induced laryngeal hemiplegia had static pressure measurements generally outside that range. We conclude that determination of tracheal and pharyngeal pressures is a potentially useful adjunct for assessment of the proximal portion of the respiratory tract.
Показать больше [+] Меньше [-]Evaluation of an enzyme-linked immunosorbent assay for diagnosis of paratuberculosis in goats
1994
Burnside, D.M. | Rowley, B.O.
A commercial rapid-absorbed ELISA developed to detect antibodies to Mycobacterium paratuberculosis in bovine serum was modified for use with goat serum. Diagnostic sensitivity was evaluated, using a group of 163 goats from a herd with endemic paratuberculosis. Blood and fecal samples were obtained simultaneously, and prevalence of shedding of M paratuberculosis in the feces was estimated by detection of DNA of the mycobacterial insertion sequence, IS900, using a commercial test kit. Diagnostic specificity was evaluated, using blood samples from a total of 123 goats in 10 herds that were considered clinically free of paratuberculosis. The IS900 DNA was detected in 35 of the 163 goats (21%) from the infected herd. Serum antibody to M paratuberculosis was detected in 19 of the 35 IS900 DNA-positive goats, for apparent sensitivity of 54%. Serum antibody was detected in 18 of the 128 IS900 DNA-negative goats from the infected herd. Negative results for serum antibody to M paratuberculosis were obtained for all 123 goats from the herds that were considered clinically free of paratuberculosis.
Показать больше [+] Меньше [-]