Уточнить поиск
Результаты 1-10 из 21
Cardiovascular and pharmacokinetic effects of isoxsuprine in the horse.
1986
Matthews N.S. | Gleed R.D. | Short C.E. | Burrows K.
Dynamic contrast-enhanced computed tomography in 11 dogs with orofacial tumors.
2023
Mortier, Jérémy | Maddox, Thomas W | Blackwood, Laura | La Fontaine, Matthew D | Busoni, Valeria
peer reviewed | [en] OBJECTIVE: Treatment of orofacial tumors in dogs is associated with high morbidity and reliable prognostic factors are lacking. Dynamic contrast-enhanced computed tomography (DCECT) can be used to assess tumor perfusion. The objectives of this study were to describe the perfusion parameters of different types of orofacial tumors and to describe the changes in perfusion parameters during radiotherapy (RT) in a subset of them. ANIMALS: 11 dogs with orofacial tumors prospectively recruited. CLINICAL PRESENTATION AND PROCEDURES: All dogs had baseline DCECT to assess blood volume (BV), blood flow (BF), and transit time (TT). Five dogs had repeat DCECT during megavoltage RT. RESULTS: 5 squamous cell carcinomas, 3 sarcomas, 1 melanoma, 1 histiocytic sarcoma, and 1 acanthomatous ameloblastoma were included. Blood volume and BF were higher in squamous cell carcinomas than in sarcomas, although no statistical analysis was performed. At repeat DCECT, 4 dogs showed a reduction in the size of their tumor during RT. Among these dogs, 3 showed an increase in BV and BF and 1 a decrease in these parameters between the baseline and the follow-up DCECT. The only dog whose tumor increased in size between the first and the second DCECT showed a decrease in BV and BF. CLINICAL RELEVANCE: Perfusion parameters derived from DCECT were described in a series of dogs with various types of orofacial tumors. The results suggest that epithelial tumors could have higher BV and BF than mesenchymal tumors, although larger sample sizes are needed to support these preliminary findings.
Показать больше [+] Меньше [-]Effect of slice thickness on computed tomographic perfusion analysis of the pancreas in healthy dogs
2020
Park, Seungjo | Jung, Jin-Woo | Je, Hyejin | Jang, Youjung | Choi, Jihye
OBJECTIVE To evaluate the effect of slice thickness on CT perfusion analysis of the pancreas in healthy dogs. ANIMALS 12 healthy Beagles. PROCEDURES After precontrast CT scans, CT perfusion scans of the pancreatic body were performed every second for 30 seconds by sequential CT scanning after injection of contrast medium (iohexol; 300 mg of 1/kg) at a rate of 3 mL/s. Each dog underwent CT perfusion scans twice in a crossover-design study with 2 different slice thicknesses (2.4 and 4.8 mm). Computed tomographic pancreatic perfusion variables, including blood flow, blood volume determined with the maximum slope model, times to the start of enhancement and peak enhancement, permeability, and blood volume determined by Patlak plot analysis, were measured independently by 2 reviewers. The CT perfusion variables were compared between slice thicknesses. Interoperator reproducibility was determined by ICC calculation. RESULTS Interoperator reproducibility of CT perfusion variable measurements was excellent on 2.4-mm (mean ± SD ICC, 0.81 ± 0.17) and 4.8-mm (0.90 ± 0.07) slice thicknesses, except for time to peak pancreatic enhancement on 2.4-mm-thick slices, which had moderate reproducibility (intraclass correlation coefficient, 0.473). There was no significant difference in measurements of blood flow, blood volume by either method, times to the start and peak of pancreatic enhancement, or permeability between slice thicknesses. CONCLUSIONS AND CLINICAL RELEVANCE Results supported that a thin slice thickness of 2.4 mm can be used for assessment of pancreatic perfusion variables in healthy dogs.
Показать больше [+] Меньше [-]Computed tomographic evaluation of pancreatic perfusion in healthy dogs
2020
Kloer, Timothy B. | Rao, Sangeeta | Twedt, David C. | Marolf, Angela J.
OBJECTIVE To evaluate the feasibility of contrast-enhanced CT for assessment of pancreatic perfusion in healthy dogs. ANIMALS 6 healthy purpose-bred female Treeing Walker Coonhounds. PROCEDURES Contrast-enhanced CT of the cranial part of the abdomen was performed with 3-mm slice thickness. Postprocessing computer software designed for evaluation of human patients was used to calculate perfusion data for the pancreas and liver by use of 3-mm and reformatted 6-mm slices. Differences in perfusion variables between the pancreas and liver and differences in liver-specific data of interest were evaluated with the Friedman test. RESULTS Multiple pancreatic perfusion variables were determined, including perfusion, peak enhancement index, time to peak enhancement, and blood volume. The same variables as well as arterial, portal, and total perfusion and hepatic perfusion index were determined for the liver. Values for 6-mm slices appeared similar to those for 3-mm slices. The liver had significantly greater median perfusion and peak enhancement index, compared with the pancreas. CONCLUSIONS AND CLINICAL RELEVANCE Measurement of pancreatic perfusion with contrast-enhanced CT was feasible in this group of dogs. Hepatic arterial and pancreatic perfusion values were similar to previously published findings for dogs, but hepatic portal and hepatic total perfusion measurements were not. These discrepancies might have been attributable to physiologic differences between dogs and people and related limitations of the CT software intended for evaluation of human patients. Further research is warranted to assess reliability of perfusion variables and applicability of the method for assessment of canine patients with pancreatic abnormalities.
Показать больше [+] Меньше [-]Effect of contrast medium injection rate on computed tomography-derived renal perfusion estimates obtained with the maximum slope method in healthy Beagles
2019
Yi, Sang-gwŏn | Kim, Cheolhyun | Yoon, Sooa | Choi, Jihye
OBJECTIVE To evaluate the effect of contrast medium injection rate on CT-derived renal perfusion estimates obtained with the maximum slope method in healthy small dogs. ANIMALS 6 healthy sexually intact male purpose-bred Beagles. PROCEDURES All dogs underwent CT perfusion analysis 3 times in a crossover design, receiving a different contrast medium injection rate (1.5, 3.0, and 4.5 mL/s) each time, with a 1-week interval between imaging sessions. All CT images were obtained at the level of the left renal hilus. The time to peak aortic enhancement (TPAE) and time to initial renal venous enhancement (TIRVE) were measured from time-attenuation curves. The renal CT perfusion estimates (blood flow and blood volume) were estimated by use of the maximum slope method, which assumes no venous outflow of contrast medium during CT perfusion analysis. RESULTS The TPAE occurred at or before the TIRVE at all injection rates. Median values of estimated blood flow and blood volume did not differ significantly among injection rates. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that the assumption of no venous outflow of contrast medium during renal CT perfusion analysis with the maximum slope method was satisfied for all 3 contrast medium injection rates in the evaluated dogs. A low injection rate may be more practical than higher injection rates that require large catheters for CT perfusion analysis in small dogs such as Beagles.
Показать больше [+] Меньше [-]Perfusion computed tomographic measurements of cerebral blood flow variables in live Holstein calves
2018
Kishimoto, Miori | Kushida, Kazuya | Yamada, Kazutaka
OBJECTIVE To measure cerebral blood flow (CBF) and cerebral blood volume (CBV) by means of perfusion CT in clinically normal Holstein calves. ANIMALS 9 Holstein calves. PROCEDURES Each of the 9 calves (mean age, 20.2 days) was anesthetized and received an injection of iodinated contrast medium into the right jugular vein at a rate of 4.0 mL/s. Dynamic CT scanning of the head at a level that included the mandibular condyle was initiated at the time of the contrast medium injection and continued for 100 seconds. A deconvolution method was used as an analytic algorithm. RESULTS Among the 9 calves, the mean ± SD CBF in the cerebral cortex, white matter, and thalamus was 44.3 ± 10.3 mL/100 g/min, 36.1 ± 7.5 mL/100 g/min, and 40.3 ± 7.5 mL/100 g/min, respectively. The CBF in white matter was significantly lower than that in the cerebral cortex or thalamus. The mean CBV in the cerebral cortex, white matter, and thalamus was 6.8 ± 1.0 mL/100 g, 5.2 ± 1.0 mL/100 g, and 5.7 ± 0.7 mL/100 g, respectively. The CBV in the cerebral cortex was significantly higher than that in the white matter or thalamus. CONCLUSIONS AND CLINICAL RELEVANCE Measurement of CBF and CBV in clinically normal calves by means of perfusion CT was feasible. The data obtained may be useful as baseline values for use in future research or for comparison with findings from calves with CNS diseases. Investigations to determine the lower limit of blood flow at which brain function can still be restored are warranted.
Показать больше [+] Меньше [-]Interictal diffusion and perfusion magnetic resonance imaging features of cats with familial spontaneous epilepsy
2017
Mizoguchi, Shunta | Hasegawa, Daisuke | Hamamoto, Yuji | Yu, Yoshihiko | Kuwabara, Takyuji | Fujiwara-Igarashi, Aki | Fujita, Michio
OBJECTIVE To evaluate the usefulness of diffusion and perfusion MRI of the cerebrum in cats with familial spontaneous epilepsy (FSECs) and identify microstructural and functional deficit zones in affected cats. ANIMALS 19 FSECs and 12 healthy cats. PROCEDURES Diffusion-weighted, diffusion tensor, and perfusion-weighted MRI of the cerebrum were performed during interictal periods in FSECs. Imaging findings were compared between FSECs and control cats. Diffusion (apparent diffusion coefficient and fractional anisotropy) and perfusion (relative cerebral blood volume [rCBV], relative cerebral blood flow [rCBF], and mean transit time) variables were measured bilaterally in the hippocampus, amygdala, thalamus, parietal cortex gray matter, and subcortical white matter. Asymmetry of these variables in each region was also evaluated and compared between FSECs and control cats. RESULTS The apparent diffusion coefficient of the total amygdala of FSECs was significantly higher, compared with that of control cats. The fractional anisotropy of the right side and total hippocampus of FSECs was significantly lower, compared with that of control cats. The left and right sides and total hippocampal rCBV and rCBF were significantly lower in FSECs than in control cats. The rCBV and rCBF of the parietal cortex gray matter in FSECs were significantly lower than in control cats. CONCLUSIONS AND CLINICAL RELEVANCE In FSECs, diffusion and perfusion MRI detected microstructural changes and hypoperfusion (lowered function) in the cerebrum during interictal periods from that of healthy cats. These findings indicated that diffusion and perfusion MRI may be useful for noninvasive evaluation of epileptogenic foci in cats.
Показать больше [+] Меньше [-]Alterations in blood viscosity in horses competing in cross country jumping
1994
Sommardahl, C.S. | Andrews, F.M. | Saxton, A.M. | Geiser, D.R. | Maykuth, P.L.
Packed cell volume and plasma total protein (TP), serum albumin (Alb) and globulin (Glb), and plasma ionized calcium (PCa) concentrations, blood viscosity (BV), and plasma viscosity (PV) were measured in 42 horses at rest and after the cross country jumping phase of a horse trial competition. The BV and Pv were determined at 6 shear rates (230, 115, 46, 23, 11.5, 5.75 s 1), using a digital rotational cone and plate microviscometer. A paired t-test was used to determine differences between PCV, TP, Alb, Glb and PCa values at rest and after exercise. The PCV, TP, Alb, and Glb values increased (P < 0.05) in horses after exercise. The PCa concentration decreased (P < 0.05) in horses after exercise. Mean BV and Pv in the 42 horses at rest and after exercise were fitted to an asymptotic function. Significant (P < 0.05) correlation at aH shear rates was seen between BV at rest and PCV, TP, Alb, Glb, and PCa values at rest; and between BV after exercise and PCV, TP, Alb, Glb, and PCa values after exercise. Significant correlation was not seen between PV at rest and TP, Alb, Glb, and PCa at rest, or between PV after exercise and TP, Alb, Glb, and PCa concentrations after exercise at any shear rate.
Показать больше [+] Меньше [-]Preparation and transfusion of canine platelet concentrates
1993
Abrams-Ogg, A.C.G. | Kruth, S.A. | Carter, R.F. | Valli, V.E. | Kamel-Reid, S. | Dube, I.D.
A protocol was developed for preparation of platelet concentrates (PC) to support thrombocytopenic dogs. Four clinically normal dogs with platelet counts that ranged from 200 to 330 X 10(9) platelets/L were used as donors. One unit (450 ml) of blood was collected by venipuncture into a double blood bag. Whole blood (WB) was centrifuged for 4 minutes at 1,000 X g (braking time = 2 minutes, 30 seconds) to prepare platelet-rich plasma (PRP). The PRP was expressed into the satellite bag and was centrifuged for 10 minutes at 2,000 X g (braking time = 2 minutes, 36 seconds). The platelet-poor plasma was expressed, leaving 40 to 70 ml of plasma and the pelleted platelets in the satellite bag. The resulting PC was left undisturbed for 60 minutes to promote disaggregation, and the platelets were then resuspended by gentle manual agitation. Forty-eight PC were prepared. Mean (+/- SD) platelet yield from WB to PRP was 78 +/- 13)% (range, 35 to 97%); yield from PRP to PC was 94 (+/- 6) % (range, 75 to 100%); and overall yield (PC from WB) was 74 (+/- 13) % (range, 36 to 91%). Mean PC platelet count was 8.0 (+/- 3.0) X 10(10) platelets/PC (range, 2.3 to 13.4 X 10(10) platelets/PC). The WBC content was 0.1 to 2.3 X 10(9) platelets/PC, representing 3 to 74% of WBC in the WB. Hematocrit was 0.1 to 26.2%. Results of bacterial and fungal culturing were negative.
Показать больше [+] Меньше [-]Effect of meal feeding on plasma volume and urinary electrolyte clearance in ponies
1990
Clarke, L.L. | Argenzio, R.A. | Roberts, M.C.
The effect of meal size and frequency on plasma volume, plasma aldosterone concentration and urinary Na and K clearances was determined in ponies. A daily maintenance ration of hay-grain pellets was provided either as a multiple feeding regimen, ie, 12 equal portions fed at 2-hour intervals, or as single large feedings, ie, half the ration fed every 12 hours at 0800 and 2000 hours. Only the effect of the single morning feeding was studied, using the latter regimen. Serial measurements of plasma volume were made by use of an indicator-dilution technique and indocyanine green (0.15 mg/kg of body weight, IV) that allowed repeated determinations at 2-hour intervals. Ingestion of the single large meal caused a 15% decrease in plasma volume by the end of a 1-hour feeding period. Feeding hypovolemia was confirmed by a coincident increase in plasma protein concentration (12%) and, in separate experiments, by analysis of postfeeding changes in the elimination of Evans blue dye. Plasma aldosterone concentration was significantly (P < 0.05) increased from 2 to 5 hours after feeding. Urinary Na clearance decreased in response to feeding and remained lower than the prefeeding value until 9 hours after feeding. Urinary K clearance increased from prefeeding and reached a peak value between 5 and 7 hours after feeding. Creatinine clearance was unaffected. In contrast, the aforementioned variables were unchanged during the multiple regimen. Results indicate that ingestion of a large concentrate meal by ponies causes periprandial hypovolemia, activation of the renin-angiotensin-aldosterone system, and a subsequent antinaturesis-kaluresis that lasts for several hours.
Показать больше [+] Меньше [-]