Уточнить поиск
Результаты 1-4 из 4
Effect of short-term hyperinsulinemia on the localization and expression of endothelin receptors A and B in lamellar tissue of the forelimbs of horses
2014
Gauff, Felicia C. | Patan-Zugaj, Bianca | Licka, Theresia F.
Objective—To determine the effect of short-term hyperinsulinemia on the localization and expression of endothelin receptor (ETR)-A and ETR-B in lamellar tissue of the forelimbs of horses. Samples—Distal portion of 15 cadaveric forelimbs from healthy adult horses (1 limb/horse) obtained immediately after slaughter at an abattoir. Procedures—Each forelimb was assigned to 1 of 3 treatment groups (perfused with autologous blood for 10 hours [control perfusion; n = 5], perfused with an insulin [142 ± 81 μU/mL] perfusate for 10 hours [insulinemic perfusion; 5], or not perfused [unperfused control; 5]). Immunohistochemical evaluation of lamellar tissue was performed to assess localization of ETR-A and ETR-B. Expression of ETR-A and ETR-B was measured semiquantitatively on a scale of 0 to 3 (0 = none, 1 = mild, 2 = moderate, and 3 = high-intensity staining) and quantitatively by means of gray value analysis with imaging software. Results—In all specimens, ETR-A and ETR-B were localized in endothelium, smooth muscle cells, axons, and keratinocytes. Quantitative expression of ETR-A in the midportion of the primary epidermal lamellae for the insulinemic perfusion group (149 ± 16) was lower than that for the control perfusion group (158 ± 15). Expression of ETR-B in the primary epidermal lamellae tips for the insulinemic perfusion group (140 ± 29) was higher than that for the control perfusion group (114 ± 8). Conclusions and Clinical Relevance—Hyperinsulinemia caused significant changes in endothelin receptor expression, which suggested that ETR antagonists might be beneficial for treatment of laminitis in horses.
Показать больше [+] Меньше [-]Microcirculatory effects of a hyperviscous hemoglobin-based solution administered intravenously in dogs with experimentally induced hemorrhagic shock
2014
Peruski, Ann M. | Cooper, Edward S. | Butler, Amy L.
Objective-To determine whether increasing the viscosity of a standard hemoglobin-based oxygen-carrying solution (HBOC) would offset its associated vasoconstrictive effects and result in improved microvascular perfusion in healthy splenectomized dogs with experimentally induced hemorrhagic shock. Animals-12 male American Foxhounds. Procedures-Each dog underwent anesthesia and splenectomy. Shock was induced by controlled hemorrhage until a mean arterial blood pressure of 40 mm Hg was achieved and maintained for 60 minutes. Dogs were then randomly assigned to receive either a standard or hyperviscous HBOC (6 dogs/group). Sidestream dark-field microscopy was used to assess the effects of shock and HBOC administration on the microcirculation of the buccal mucosa and the jejunal serosa. Video recordings of the microcirculation were collected before shock was induced (baseline) and at intervals up to 180 minutes following HBOC administration. Vascular analysis software was used to compute microcirculatory variables. Results-Compared with baseline findings, hemorrhagic shock resulted in decreases in all microvascular variables in the buccal mucosa and the jejunal serosa. At all time points following HBOC administration, microvascular variables were similar to initial values and no significant differences between treatment groups were detected. At all time points following HBOC administration, blood and plasma viscosities in dogs treated with the hyperviscous solution were significantly higher than values in dogs receiving the standard solution. Conclusions and Clinical Relevance-In splenectomized dogs with experimentally induced hemorrhagic shock, administration of a hyperviscous HBOC did not significantly affect microvascular variables, compared with effects of a standard HBOC. Microcirculatory flow returned to baseline values in both treatment groups, suggesting that marked HBOC-associated vasoconstriction did not occur.
Показать больше [+] Меньше [-]In vivo proton magnetic resonance spectroscopy for the evaluation of hepatic encephalopathy in dogs
2014
Carrera, Ines | Kircher, Patrick R. | Meier, Dieter | Richter, Henning | Beckman, Katrin | Dennler, Matthias
Objective—To investigate clinical use of proton magnetic resonance spectroscopy (1H MRS) and to compare metabolic brain bioprofiles of dogs with and without hepatic encephalopathy. Animals—6 dogs with hepatic encephalopathy and 12 control dogs. Procedures—Conventional MRI and single-voxel 1H MRS were performed with a 3-T magnet. Images for routine MRI planes and sequences were obtained. Single-voxel 1H MRS was performed with a point-resolved sequence with a short echo time (35 milliseconds) and voxel of interest placement at the level of the basal ganglia. Metabolites of interest included the glutamine-glutamate complex (sum quantification of glutamate and glutamine), myoinositol, N-acetyl aspartate, total choline, and creatine. Data were analyzed with postprocessing fitting algorithm software, and metabolite concentration relative to water and ratios with creatine as the reference metabolite were calculated. Results—Compared with control dogs, dogs with hepatic encephalopathy had specific changes, which included significantly higher concentration relative to water of the glutamine-glutamate complex and significantly lower concentration of myoinositol. Choline and N-acetyl aspartate concentrations were also slightly lower in dogs with hepatic encephalopathy than in control dogs. No differences in creatine concentration were detected between groups. Conclusions and Clinical Relevance—1H MRS aided in the diagnosis of hepatic encephalopathy in dogs, and findings supported the assumption that ammonia is a neurotoxin that manifests via glutamine-glutamate complex derangements. Use of 1H MRS may provide clinically relevant information in patients with subclinical hepatic encephalopathy, equivocal results of bile acids tests, and equivocal ammonia concentrations or may be helpful in monitoring efficacy of medical management.
Показать больше [+] Меньше [-]Effect of region of interest and slice thickness on vertebral bone mineral density measured by use of quantitative computed tomography in dogs
2014
Bae, Yeonho | Park, Seungjo | Jeon, Sunghoon | Lee, Gahyun | Choi, Jihye
Objective—To determine the effect of region of interest (ROI) setting and slice thickness on trabecular bone mineral density (BMD) measured with quantitative CT in dogs. Animals—14 healthy Beagles. Procedures—CT of the lumbar vertebrae and a quantitative CT phantom was performed. The BMD of trabecular bone was measured from L1 to L7 in 2 ways in all dogs. First, sequential 9.6-mm-thick CT images were acquired and then CT images were reconstructed into transverse CT images with slice thicknesses of 2.4, 4.8, and 9.6 mm. The obtained images were analyzed by circular ROI and trace ROI methods. Second, lumbar vertebrae were scanned with the installed quantitative CT protocol with a slice thickness of 10 mm and then the CT images were analyzed by installed automatic BMD software. Results—Interclass correlation coefficients of the automatic software (0.975 to 1.0) and the circular method (0.871 to 0.996) were high, compared with those of the trace method (0.582 to 0.996). The BMD measured with the automatic software was not significantly different from that measured with circular ROI and a slice thickness of 9.6 mm. The BMD measured by use of the circular method was not different according to slice thickness. Conclusions and Clinical Relevance—Results obtained by use of automatic software were similar to those obtained by use of more manual methods. The CT images with thinner slice thickness (2.4 and 4.8 mm) could be used in dogs of toy and small breeds to measure lumbar vertebrae BMD to reduce the limitations of the standard 10-mm slice thickness.
Показать больше [+] Меньше [-]