Уточнить поиск
Результаты 1-2 из 2
The use of the water treadmill for the rehabilitation of musculoskeletal injuries in the sport horse
2019
Muñoz, Ana | Saitua, Aritz | Becero, Mireya | Riber, Cristina | Satué, Katy | Medina, Antonia Sánchez de | Argüelles, David | Castejón-Riber, Cristina
In recent years, exercise on a water treadmill has come to have great relevance in rehabilitation and training centres for sport horses. Its use exploits certain physical properties of water, related to the fundamental principles of hydrodynamics, such as buoyancy, viscosity, hydrostatic pressure, and water temperature. These properties together with deliberate specification of the depth of the water and the velocity of the treadmill provide a combination of parameters that can be varied according to the purpose of the rehabilitation or training programme, the disease to rehabilitate, or the healing phase. In the current article, kinematic adaptations to exercise on a water treadmill and the direct application of such exercise to the rehabilitation of superficial and deep digital flexor tendon and accessory ligament injuries and back and joint diseases are described.
Показать больше [+] Меньше [-]Radiation exposure of dogs and cats undergoing fluoroscopic procedures and for operators performing those procedures
2019
Hersh-Boyle, Rebecca A. | Culp, William T. N. | Brown, Dorothy C. | Luskin, Austin C. | Kapatkin, Amy S. | Chou, Po-Yen | Agnello, Kimberly A. | Reetz, Jennifer A. | Oyama, Mark A. | Visser, Lance C. | Palm, Carrie A. | Clarke, Dana L.
OBJECTIVE To evaluate radiation exposure of dogs and cats undergoing procedures requiring intraoperative fluoroscopy and for operators performing those procedures. SAMPLE 360 fluoroscopic procedures performed at 2 academic institutions between 2012 and 2015. PROCEDURES Fluoroscopic procedures were classified as vascular, urinary, respiratory, cardiac, gastrointestinal, and orthopedic. Fluoroscopy operators were classified as interventional radiology-trained clinicians, orthopedic surgeons, soft tissue surgeons, internists, and cardiologists. Total radiation exposure in milligrays and total fluoroscopy time in minutes were obtained from dose reports for 4 C-arm units. Kruskal-Wallis equality of populations rank tests and Dunn pairwise comparisons were used to compare differences in time and exposure among procedures and operators. RESULTS Fluoroscopy time (median, 35.80 minutes; range, 0.60 to 84.70 minutes) was significantly greater and radiation exposure (median, 137.00 mGy; range, 3.00 to 617.51 mGy) was significantly higher for vascular procedures than for other procedures. Median total radiation exposure was significantly higher for procedures performed by interventional radiology-trained clinicians (16.10 mGy; range, 0.44 to 617.50 mGy), cardiologists (25.82 mGy; range, 0.33 to 287.45 mGy), and internists (25.24 mGy; range, 3.58 to 185.79 mGy). CONCLUSIONS AND CLINICAL RELEVANCE Vascular fluoroscopic procedures were associated with significantly longer fluoroscopy time and higher radiation exposure than were other evaluated fluoroscopic procedures. Future studies should focus on quantitative radiation monitoring for patients and operators, importance of operator training, intraoperative safety measures, and protocols for postoperative monitoring of patients.
Показать больше [+] Меньше [-]