Уточнить поиск
Результаты 1-3 из 3
Effect of topical administration of 0.1% diclofenac sodium ophthalmic solution at four frequencies on intraocular pressure in healthy Beagles
2020
Martabano, Brittany B. | De Linde Henriksen, Michala | Colussi, Jenny A. | Sharop, Julia L. | Wang, Zeke | Lappin, Michael R.
OBJECTIVE To evaluate effects of topical ophthalmic administration of diclofenac on intraocular pressure (IOP) when applied at 4 frequencies to eyes of Beagles. ANIMALS 8 ophthalmologically normal Beagles. PROCEDURES The study involved four 5-day experimental periods each separated by a 16-day washout period. During each period, 1 drop of 0.1% diclofenac sodium ophthalmic solution was administered to the right eye at 4 treatment frequencies (1, 2, 3, or 4 times/d); 1 drop of eyewash was administered to the left eye as a control treatment. A complete ophthalmic examination was performed on days 0 (day before first treatment) and 5 of each experimental period. Gonioscopy was performed on day 0 of the first period. The IOPs were measured at 7 am and 7 pm on days 1 through 5. RESULTS No abnormalities were detected during neuro-ophthalmic and ophthalmic examinations on day 0 of each experimental period. No adverse reactions to administration of diclofenac or eyewash were observed at any time point. No abnormalities were detected during ophthalmic examinations performed on day 5, and IOPs remained < 25 mm Hg in all 4 periods. No significant differences were identified between the treated and control eyes or among the 4 treatment frequencies. CONCLUSIONS AND CLINICAL RELEVANCE Topical ophthalmic administration of diclofenac up to 4 times/d in dogs with no ophthalmic abnormalities did not significantly increase the IOP. Additional research is needed to evaluate the effect of topical ophthalmic administration of diclofenac on IOP in dogs with anterior uveitis.
Показать больше [+] Меньше [-]Evaluation of a multipump air pistol as a method for euthanizing young dairy goat kids
2020
Hempstead, Melissa N. | Fowler, Jennifer L. | Shearer, Jane K. | Plummer, Paul J.
OBJECTIVE To assess the extent of damage to the skull and brain of cadaveric dairy goat kids caused by a .22-caliber, 16-g pellet fired from a multipump air pistol at various power levels. SAMPLE Cadavers of 8 male and 7 female dairy goat kids ≤ 5 days old. PROCEDURES Each cadaver was positioned in sternal recumbency with the head and neck extended on a straw bale. A multipump air pistol was held with the barrel perpendicular to and 2.5 cm from the head at the intersection of 2 imaginary lines that extended from the lateral canthus of each eye to the middle of the contralateral ear base and fired at half (5 pumps; n = 2), intermediate (7 pumps; 2), or full (10 pumps; 11) power. The head and neck were removed from the carcass for CT imaging and gross sectioning to determine the location of the pellet and extent of damage caused to the skull and brain. RESULTS The pellet successfully penetrated the skull of all 13 heads shot at full or intermediate power and 1 of the 2 heads shot at half power. The pellet did not fragment after entering the skull of any cadaver and penetrated the brainstem (necessary for instantaneous death) in only 7 cadavers. CONCLUSIONS AND CLINICAL RELEVANCE The described technique was insufficient for use as a stand-alone method for euthanizing young dairy goat kids. Modification of the technique warrants further research to determine whether air pistols can be used to effectively euthanize young goat kids.
Показать больше [+] Меньше [-]Effectiveness of MB-102, a novel fluorescent tracer agent, for conducting ocular angiography in dogs
2020
Pirie, Christopher G. | Rogers, Thomas E. | Dorshow, Richard B.
OBJECTIVE To evaluate the effectiveness of a novel fluorescence tracer agent, MB-102, for conducting ocular angiography in dogs. ANIMALS 10 ophthalmologically normal dogs (2 to 4 years old) and 10 dogs with retinal degeneration or primary open-angle glaucoma (< 6 years old). PROCEDURES While anesthetized, all dogs received sodium fluorescein (20 mg/kg, IV) or MB-102 (20 or 40 mg/kg, IV) first and then the other dye in a second treatment session 2 days later in a randomized crossover design. Anterior fluorescence angiography was performed on one eye and posterior fluorescence angiography on the other. Imaging was performed with a full-spectrum camera and camera adaptor system. Filter sets that were tailored to match the excitation and emission characteristics of each angiographic fluorescent agent were used. RESULTS All phases and phase intervals during anterior and posterior segment angiography were identified, regardless of the dye used. However, agent fluorescence and visualization of the iridal blood vessels were hindered in some dogs, irrespective of agent, owing to the degree of iridal pigmentation present. No significant difference was noted between the 2 dyes in any phase or phase interval, and slight improvement in image contrast was observed with MB-102 during the venous phases owing to a reduction of vessel wall staining in both normal and diseased eyes. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that MB-102 would be useful for conducting ocular angiography in dogs.
Показать больше [+] Меньше [-]