Уточнить поиск
Результаты 1-10 из 28
Colistin resistance of non-pathogenic strains of Escherichia coli occurring as natural intestinal flora in broiler chickens treated and not treated with colistin sulphate
2020
Majewski, Michał | Łukomska, Anna | Wilczyński, Jarosław | Wystalska, Danuta | Racewicz, Przemysław | Nowacka-Woszuk, Joanna | Pszczola, Marcin | Anusz, Krzysztof
A significant threat to public health is presented by antibiotic-resistant strains of bacteria, selective pressure on which results from antibiotic use. Colistin is an antibiotic commonly used in veterinary medicine, but also one of last resort in human medicine. Since the 2015 discovery in China of the mcr-1 gene encoding colistin resistance in Enterobacteriaceae, other countries have noted its presence. This study was to find the mcr-1 gene prevalence in E. coli isolated from poultry slaughtered in Poland. Cloacal swabs were taken from December 2017 to October 2018 from broiler chickens in three regions. The samples (n = 158) were grouped as flocks treated with colistin sulphate (n = 87) and those not treated (n = 71). Resistance to antimicrobials commonly used in poultry was evaluated by minimum inhibitory concentration. The presence of the mcr-1 gene was confirmed by PCR. Isolates containing the mcr-1 gene were yielded by 11.27% of the samples from not treated flocks and 19.54% of those from treated flocks, but no statistically significant difference in the prevalence of the gene was seen between the groups. The results clearly preclude intensification of selective pressure for colistin resistance due to colistin sulphate treatment because they show that the avian gastrointestinal tract was already inhabited by colistin-resistant E. coli by the time the chickens came to the poultry house.
Показать больше [+] Меньше [-]Simvastatin-induced changes in the leukocytic system of porcine bone marrow
2018
Snarska, Anna | Wysocka, Dominika | Rytel, Liliana | Gonkowski, Sławomir | Pawelec, Hanna | Sobiech, Przemysław
Simvastatin is a substance which is commonly used as a medicine to reduce cholesterol level. Unfortunately, it shows numerous side effects. Simvastatin affects various internal organs, and among other detriments to health may cause persistent muscle weakness, osteolytic processes, headaches, and rashes. Until now knowledge of the influence of simvastatin on bone marrow cells has been rather scant and fragmentary. During this experiment the numbers of all types of cells in the leukocytic system of porcine bone marrow were evaluated after 28 and 56 days of oral administration of simvastatin at a dose of 40 mg/day/animal. Simvastatin caused an increase in the number of all types of cells in the leukocytic system, and the most visible fluctuations concerned promyelocytes. Observations obtained during the present study indicated that the results of the action of simvastatin on porcine bone marrow differ from those observed in other mammal species, including human. This may be due to various metabolic pathways within the bone marrow in the particular species, but the exact mechanisms of these actions are unknown at the present time.
Показать больше [+] Меньше [-]Electroencephalography as a diagnostic technique for canine neurological diseases
2016
Wrzosek, Marcin
Electroencephalography (EEG) is a non-invasive examination method for the assessment of functional central nervous system (CNS) disturbances. In human medicine it has a special importance as a diagnostic tool for epilepsy. Although many studies were done on the use of EEG for diagnostics of canine central nervous system disorders, the technique is still not applied routinely. The purpose of this paper was to review the use of the electroencephalography in canine neurological disorders of central nervous system diagnosis and assess the future perspectives of this technique in veterinary medicine.
Показать больше [+] Меньше [-]Use of aVR and Jastrzębski algorithms in the classification of wide complex tachycardia in dogs – a preliminary study
2018
Michałek, Marcin | Frydrychowski, Piotr | Adamowicz, Jakub | Sławuta, Agnieszka | Pasławska, Urszula | Noszczyk-Nowak, Agnieszka
Ventricular rhythm disturbances are a common pathology in human and veterinary medicine. In humans, the algorithmic approach is used to differentiate wide QRS complex tachycardia. The most commonly used are the aVR and Brugada algorithms as well as the ventricular tachycardia (VT) score developed by Jastrzębski and coworkers. In veterinary medicine, no such algorithms are available and the only parameter used to describe VT abnormalities is the duration of the QRS complexes. The aim of this analysis was determining whether human medicine algorithms for VT are applicable in veterinary medicine to differentiate wide QRS complex tachycardia in dogs. A retrospective analysis was performed on 11 dogs of both sexes and various breeds and age diagnosed with VT. The diagnosis was based on ambulatory ECG, further established based on the reaction to lidocaine or adenosine or an invasive electrophysiological study. Of the 11 tracings passed through the aVR algorithm, 10 met the VT criteria. The most common criterion was the Vi/Vt ratio (8 out of 11 tracings). Based on the VT score, seven out of eight dogs had a high probability of VT. Retrospective analysis of ECGs by aVR and VT score indicates that the applied algorithms may be useful in differentiating wide QRS complex tachycardia as a quick, easy, and non-invasive alternative to cardiac electrophysiology.
Показать больше [+] Меньше [-]Evaluation of metallothionein and Ki-67 expression in chronic cholangiohepatitis in cats
2021
Jose, Divya | Allen, Andrew L. | Blakley, Barry | Al-Dissi, Ahmad
Chronic cholangiohepatitis (CCH) is a common pathological condition in cats with a guarded prognosis and unknown etiology. Recently, in human medicine, there has been increased interest in enhancing liver defense mechanisms as an effective treatment strategy to control liver diseases that have a poor prognosis. Metallothionein (MT) is a ubiquitous protein, which has been widely researched for its role in liver defense through heavy metal detoxification, neutralization of reactive oxygen species, and liver regeneration. In this study, immunohistochemistry was used to evaluate the role of MT in CCH and hepatocellular regeneration in 34 cats histologically diagnosed with this condition by assessing the correlation between hepatocellular MT and Ki-67 (marker for cellular proliferation) expression with histological parameters of CCH, such as inflammation, fibrosis, and bile duct proliferation. Statistical analysis was performed using the Spearman-rank correlation test. A significant positive correlation was observed between inflammation and the number of MT-positive hepatocytes (r = 0.36, P = 0.03) and MT labelling intensity (r = 0.37, P = 0.03). In 16 of 34 cases (47%) MT labelling intensity was noted to be pronounced towards the centrilobular zone and very weak or absent towards the portal zone. The results suggest that MT is induced in the liver during chronic inflammatory conditions, which could be speculated as a host defensive mechanism to protect the liver from inflammation-mediated liver injury. Therapeutic interventions utilizing MT, therefore, may have a positive effect on cats with chronic cholangiohepatitis.
Показать больше [+] Меньше [-]Changes in antimicrobial resistance levels among Escherichia coli, Salmonella, and Campylobacter in Ontario broiler chickens between 2003 and 2015
2018
Poultry has been identified as a reservoir of foodborne enteric pathogens and antimicrobial resistant bacteria. The objective of this study was to describe and compare antimicrobial resistant isolates from an Ontario broiler chicken farm-level baseline project (2003 to 2004) to the Canadian Integrated Program for Antimicrobial Resistance Surveillance (CIPARS) Ontario abattoir and retail surveillance data from 2003, and to the most recent (2015) CIPARS Ontario chicken surveillance data in order to assess the impact of an industry-wide policy change in antimicrobial use. Ceftiofur resistance (TIO-R) prevalence in Salmonella decreased by 7% on farm between 2003 and 2004 and 2015. During the same timeframe, TIO-R E. coli prevalence decreased significantly by 16%, 11%, and 8% in farm, abattoir, and retail samples, respectively. Gentamicin resistant (GEN-R) E. coli, however, increased by 10% in farm and 15% in retail-derived isolates, and trimethoprim-sulfamethoxazole resistant (TMSm-R) E. coli increased significantly by 20%, 18%, and 5% in farm, abattoir, and retail isolates, respectively. Similarly, ciprofloxacin-resistant (CIP-R) Campylobacter spp. significantly increased in retail isolates by 11% and increased in farm (33%) and abattoir isolates (7%). The decrease in TIO-R Salmonella/E. coli in recent years is consistent with the timing of an industry-led intervention eliminating the preventive use of ceftiofur, a third generation cephalosporin and class of antimicrobials deemed critically important to human medicine. The rise in GEN-R and TMSm-R prevalence is indicative of recent shifts in antimicrobial use. Our study highlights the importance of integrated surveillance in detecting emerging trends and determining the efficacy of interventions to improve food safety.
Показать больше [+] Меньше [-]Cystic duct pressures after ligation with a novel absorbable device in an ex vivo caprine cholecystectomy model
2017
Sundholm Tepper, A. J. | Höglund, O. V. | Campbell, B. G. | Chen, Zhengyou | Fransson, B. A.
Laparoscopic cholecystectomy is the standard of care in human medicine for gall bladder disease. Although infrequently reported in veterinary literature, laparoscopic cholecystectomy is an option for uncomplicated gall bladder disease in canine patients. Due to the risk of cystic duct ligature slippage or clip dislodgement, we wanted to explore the use of a LigaTie; a novel absorbable medical device modeled after a cable tie. Our object was to describe the use of the LigaTie in a caprine cadaveric study of cholecystectomies as a model for canine patients and demonstrate the leak pressure of the cystic duct compared with cholecystectomies performed with 2 large endoscopic hemoclips. Samples of caprine gall bladder, liver, and cystic duct were collected. The cystic duct was ligated with either 2 large endoscopic hemoclips or a LigaTie. Maximum cystic duct pressure was recorded. Results showed that there was no statistically significant difference in the maximum cystic duct pressure achieved for cystic ducts ligated with 2 large endoscopic hemoclips or the LigaTie (P = 0.865). No leakage was observed from the cystic duct, hemoclip, or LigaTie site in either group. Supraphysiologic pressures were achieved in both groups and high pressure occlusion of the infusion pump determined the maximum intraluminal pressure achieved. Based on these results, the LigaTie may provide advantages in minimally invasive surgery, especially when considering ligation of a friable or thickened cystic duct during laparoscopic cholecystectomy. Future in vivo studies are warranted to determine minimally invasive maneuverability, tissue interaction, complications, and outcomes.
Показать больше [+] Меньше [-]Assessment of contrast-enhanced ultrasonography of the hepatic vein for detection of hemodynamic changes associated with experimentally induced portal hypertension in dogs
2017
Morishita, Keitaro | Hiramoto, Akira | Michishita, Asuka | Takagi, Satoshi | Hoshino, Yuki | Itami, Takaharu | Lim, Sue Yee | Osuga, Tatsuyuki | Nakamura, Sayrui | Ochiai, Kenji | Nakamura, Kensuke | Ohta, Hiroshi | Yamasaki, Masahiro | Takiguchi, Mitsuyoshi
OBJECTIVE To assess the use of contrast-enhanced ultrasonography (CEUS) of the hepatic vein for the detection of hemodynamic changes associated with experimentally induced portal hypertension in dogs. ANIMALS 6 healthy Beagles. PROCEDURES A prospective study was conducted. A catheter was surgically placed in the portal vein of each dog. Hypertension was induced by intraportal injection of microspheres (10 to 15 mg/kg) at 5-day intervals via the catheter. Microsphere injections were continued until multiple acquired portosystemic shunts were created. Portal vein pressure (PVP) was measured through the catheter. Contrast-enhanced ultrasonography was performed before and after establishment of hypertension. Time-intensity curves were generated from the region of interest in the hepatic vein. Perfusion variables measured for statistical analysis were hepatic vein arrival time, time to peak, time to peak phase (TTPP), and washout ratio. The correlation between CEUS variables and PVP was assessed by use of simple regression analysis. RESULTS Time to peak and TTPP were significantly less after induction of portal hypertension. Simple regression analysis revealed a significant negative correlation between TTPP and PVP. CONCLUSIONS AND CLINICAL RELEVANCE CEUS was useful for detecting hemodynamic changes associated with experimentally induced portal hypertension in dogs, which was characterized by a rapid increase in the intensity of the hepatic vein. Furthermore, TTPP, a time-dependent variable, provided useful complementary information for predicting portal hypertension. IMPACT FOR HUMAN MEDICINE Because the method described here induced presinusoidal portal hypertension, these results can be applied to idiopathic portal hypertension in humans.
Показать больше [+] Меньше [-]Effects of catheter shape, interelectrode spacing, and electrode size on transesophageal atrial pacing in dogs
2016
Sanders, Robert A. | Chapel, Emily H.
OBJECTIVE To determine effects of catheter shape, interelectrode spacing (IS), and electrode size (ES) on pacing threshold (PT), extraneous muscular stimulation (EMS), and zone of capture (ZOC) for dogs undergoing transesophageal atrial pacing (TAP). ANIMALS 10 purpose-bred dogs without cardiac conduction disturbances. PROCEDURES 7 configurations for TAP catheters were tested in each dog to evaluate effects of catheter shape (curved or straight), IS (5, 15, and 25 mm), and ES (2, 4, and 6 mm). Each catheter was passed into the esophagus to a location aboral to the heart and slowly withdrawn until atrial pacing was achieved. Then, catheters were withdrawn in 5-mm increments until pacing could not be achieved. Outcomes measured at each pacing site included PT, degree of EMS, and ZOC. RESULTS There was a significantly lower PT, wider ZOC, and less EMS for the curved catheter than for the straight catheter. An ES of 6 mm induced significantly more EMS than was induced by an ES of 2 or 4 mm. An IS of 5 mm induced significantly less EMS and a significantly narrower ZOC but required a significantly higher PT, compared with results for an ES of 15 or 25 mm. Additionally, there was a significant direct correlation between IS and ZOC. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that a curved catheter with multiple 4-mm electrodes that provides for variable IS would be ideal for TAP in dogs. IMPACT FOR HUMAN MEDICINE TAP catheters currently used in human medicine are straight. The PT in humans may potentially be reduced with curved catheters.
Показать больше [+] Меньше [-]Assessment of left ventricular volume and function in healthy dogs by use of one-, two-, and three-dimensional echocardiography versus multidetector computed tomography
2016
Scollan, Katherine F. | Stieger-Vanegas, Susanne M. | Sisson, D David
OBJECTIVE To compare left ventricle (LV) volume and function variables obtained by use of 1-D, 2-D, and real-time 3-D echocardiography versus ECG-gated multidetector row CT (MDCT) angiography, which was considered the criterion-referenced standard. ANIMALS 6 healthy, purpose-bred dogs. PROCEDURES Dogs were anesthetized and administered a constant rate infusion of esmolol, and 1-D, 2-D, and 3-D echocardiography and ECG-gated, contrast-enhanced MDCT were performed. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume, and ejection fraction (EF) were calculated by use of the Teichholz method for 1-D echocardiography, single-plane and biplane modified Simpson method of disks (MOD) and area-length method for 2-D echocardiography, and real-time biplane echocardiography (RTBPE) and real-time 3-D echocardiography (RT3DE) for 3-D echocardiography. Volumes were indexed to body surface area and body weight. Median values, correlations, and limits of agreement were compared between echocardiographic modalities and MDCT. RESULTS EDV and ESV measured by use of RTBPE and RT3DE had the strongest correlations with results for MDCT. Values obtained for EDV, ESV, stroke volume, and EF did not differ significantly between echocardiographic methods and MDCT. Use of RT3DE and RTBPE slightly underestimated EDV, ESV, and EF, compared with values for MDCT, as determined with Bland-Altman analysis. CONCLUSIONS AND CLINICAL RELEVANCE Values for EDV and ESV obtained by use of 3-D echocardiography, including RTBPE and RT3DE, had the highest correlation with slight underestimation, compared with values obtained by use of MDCT. This was similar to results for 3-D echocardiography in human medicine.
Показать больше [+] Меньше [-]