Уточнить поиск
Результаты 1-3 из 3
Gait abnormalities caused by selective anesthesia of the suprascapular nerve in horses
2006
Devine, D.V. | Jann, H.W. | Payton, M.E.
Objective-To assess gait abnormalities associated with selective anesthesia of the suprascapular nerve (SSN) achieved by use of perineural catheterization and thereby determine the function of that nerve as it relates to gait in horses. Animals-3 adult horses with no preexisting clinically apparent lameness at a walk. Procedure-Each horse was anesthetized; the right SSN was exposed surgically for placement of a perineural catheter to permit delivery of 1 mL of 2% mepivacaine hydrochloride. Six hours after recovery from anesthesia, each horse was videotaped while walking (50-step data acquisition period) before and after administration of mepivacaine. Videotapes were reviewed and the proportion of abnormal steps before and after selective SSN anesthesia was assessed. A step was considered abnormal if a marked amount of scapulohumeral joint instability (ie, lateral luxation of the proximal portion of the humerus) was observed during the weight-bearing phase of the stride. Results-Clinically apparent gait dysfunction was detected in all 3 horses following perineural administration of the local anesthetic agent. Anesthesia of the SSN resulted in scapulohumeral joint instability as evidenced by consistent lateral excursion of the shoulder region during the weight-bearing phase of gait at a walk. The proportion of abnormal steps before and after SSN anesthesia was significantly different in all 3 horses. Conclusions and Clinical Relevance-These data support the role of the SSN in shoulder joint stability in horses and define SSN dysfunction as 1 mechanism by which the syndrome and gait dysfunction clinically referred to as sweeny may develop.
Показать больше [+] Меньше [-]Effect of radiographic technique on assessment of liver size in Beagles
2018
Cha, Ahyoung | Park, Seungjo | Kim, Choelyhyun | Yoon, Sooa | Lee, Dahae | Kim, Dongeun | Chang, Dong Woo | Choi, Jihye
OBJECTIVE To investigate the effects of respiratory phase, body position, beam center location, and gastric distention on radiographic assessment of liver size in dogs. ANIMALS 12 Beagles. PROCEDURES Liver length and the ratio of liver length to T11 length were determined on lateral radiographic views obtained with various techniques. Images were acquired at maximal expiration or maximal inspiration, with dogs in right or left recumbency, with the beam centered on the caudal border of the scapula or the 13th rib, and after food was withheld or with gastric distention. Effects on organs adjacent to the liver were assessed with CT. Changes of the thoracic cavity during the respiratory cycle were investigated with fluoroscopy. RESULTS Liver length was significantly greater on radiographs obtained at maximal expiration than at maximal inspiration, but there was no increase in the ratio of liver length to T11 length. Body position, beam center location, and gastric distention did not significantly affect liver size. For CT, location of the spleen and stomach and location or size of the liver did not change markedly between right and left recumbency. Fluoroscopy revealed that thoracic width was less at maximal expiration than maximal inspiration. CONCLUSIONS AND CLINICAL RELEVANCE Liver length was greater at maximal expiration than at maximal inspiration because of a smaller thoracic width. Body position, beam center location, and gastric distention did not affect liver length. The ratio of liver length to T11 length was not significantly affected by any of the factors investigated.
Показать больше [+] Меньше [-]Three-dimensional inverse dynamics of the forelimb of Beagles at a walk and trot
2017
Andrada, Emanuel | Reinhardt, Lars | Lucas, Karin | Fischer, Martin S.
OBJECTIVE To perform 3-D inverse dynamics analysis of the entire forelimb of healthy dogs during a walk and trot. ANIMALS 5 healthy adult Beagles. PROCEDURES The left forelimb of each dog was instrumented with 19 anatomic markers. X-ray fluoroscopy was used to optimize marker positions and perform scientific rotoscoping for 1 dog. Inverse dynamics were computed for each dog during a walk and trot on the basis of data obtained from an infrared motion-capture system and instrumented quad-band treadmill. Morphometric data were obtained from a virtual reconstruction of the left forelimb generated from a CT scan of the same dog that underwent scientific rotoscoping. RESULTS Segmental angles, torque, and power patterns were described for the scapula, humerus, ulna, and carpus segments in body frame. For the scapula and humerus, the kinematics and dynamics determined from fluoroscopy-based data varied substantially from those determined from the marker-based data. The dominant action of scapular rotation for forelimb kinematics was confirmed. Directional changes in the torque and power patterns for each segment were fairly consistent between the 2 gaits, but the amplitude of those changes was often greater at a trot than at a walk. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that control of the forelimb joints of dogs is similar for both a walk and trot. Rotation of the forelimb around its longitudinal axis and motion of the scapula should be reconsidered in the evaluation of musculoskeletal diseases, especially before and after treatment or rehabilitation.
Показать больше [+] Меньше [-]