Уточнить поиск
Результаты 1-6 из 6
Accuracy of noninvasive, single-plane fluoroscopic analysis for measurement of three-dimensional femorotibial joint poses in dogs
2014
Jones, Stephen C. | Kim, Stanley E. | Banks, Scott A. | Conrad, Bryan P. | Abbasi, Abdullah Z. | Tremolada, Giovanni | Lewis, Daniel D. | Pozzi, Antonio
Objective - To compare accuracy of a noninvasive single-plane fluoroscopic technique with radiostereometric analysis (RSA) for determining 3-D femorotibial poses in a canine cadaver with normal stifle joints. Sample- Right pelvic limb from a 25-kg adult mixed-breed dog. Procedures- A CT scan of the limb was obtained before and after metal beads were implanted into the right femur and tibia. Orthogonal fluoroscopic images of the right stifle joint were acquired to simulate a biplanar fluoroscopic acquisition setup. Images were obtained at 5 flexion angles from 110° to 150° to simulate a gait cycle; 5 cycles were completed. Joint poses were calculated from the biplanar images by use of RSA with CT-derived beaded bone models and compared with measurements obtained by use of CT-derived nonbeaded bone models matched to single-plane, lateral-view fluoroscopic images. Single-plane measurements were performed by 2 observers and repeated 3 times by the primary observer. Results- Mean absolute differences between the single-plane fluoroscopic analysis and RSA measurements were 0.60, 1.28, and 0.64 mm for craniocaudal, proximodistal, and mediolateral translations, respectively, and 0.63°, 1.49°, and 1.58° for flexion-extension, abduction-adduction, and internal-external rotations, respectively. Intra- and interobserver repeatability was strong with maximum mean translational and rotational SDs of 0.52 mm and 1.36°, respectively. Conclusions and Clinical Relevance- Results suggested that single-plane fluoroscopic analysis performed by use of CT-derived bone models is a valid, noninvasive technique for accurately measuring 3-D femorotibial poses in dogs.
Показать больше [+] Меньше [-]Accuracy of noninvasive, single-plane fluoroscopic analysis for measurement of three-dimensional femorotibial joint poses in dogs treated by tibial plateau leveling osteotomy
2014
Jones, Stephen C. | Kim, Stanley E. | Banks, Scott A. | Conrad, Bryan P. | Abbasi, Abdullah Z. | Tremolada, Giovanni | Lewis, Daniel D. | Pozzi, Antonio
Objective- To compare accuracy of a noninvasive single-plane fluoroscopic analysis technique with radiostereometric analysis (RSA) for determining 3-D femorotibial poses in a canine cadaver stifle joint treated by tibial-plateau-leveling osteotomy (TPLO). Sample- Left pelvic limb from a 25-kg adult mixed-breed dog. Procedures- A CT scan of the left pelvic limb was performed. The left cranial cruciate ligament was transected, and a TPLO was performed. Radiopaque beads were implanted into the left femur and tibia, and the CT scan was repeated. Orthogonal fluoroscopic images of the left stifle joint were acquired at 5 stifle joint flexion angles ranging from 110° to 150° to simulate a gait cycle; 5 gait cycles were completed. Joint poses were calculated from the biplanar images by use of a digitally modified RSA and were compared with measurements obtained by use of hybrid implant-bone models matched to lateral-view fluoroscopic images. Single-plane measurements were performed by 2 observers and repeated 3 times by the primary observer. Results- Mean absolute differences between results of the single-plane fluoroscopic analysis and modified RSA were 0.34, 1.05, and 0.48 mm for craniocaudal, proximodistal, and mediolateral translations, respectively, and 0.56°, 0.85°, and 1.08° for flexion-extension, abduction-adduction, and internal-external rotations, respectively. Intraobserver and interobserver mean SDs did not exceed 0.59 mm for all translations and 0.93° for all rotations. Conclusions and Clinical Relevance- Results suggested that single-plane fluoroscopic analysis by use of hybrid implant-bone models may be a valid, noninvasive technique for accurately measuring 3-D femorotibial poses in dogs treated with TPLO.
Показать больше [+] Меньше [-]Application of a novel sorting system for equine mesenchymal stem cells (MSCs)
2014
Radtke, Catherine L. | Nino-Fong, Rodolfo | Esparza Gonzalez, Blanca P. | McDuffee, Laurie A.
The objective of this study was to validate non-equilibrium gravitational field-flow fractionation (GrFFF), an immunotag-less method of sorting mesenchymal stem cells (MSCs) into subpopulations, for use with MSCs derived from equine muscle tissue, periosteal tissue, bone marrow, and adipose tissue. Cells were collected from 6 young, adult horses, postmortem. Cells were isolated from left semitendinosus muscle tissue, periosteal tissue from the distomedial aspect of the right tibia, bone marrow aspirates from the fourth and fifth sternebrae, and left supragluteal subcutaneous adipose tissue. Aliquots of 800 × 10(3) MSCs from each tissue source were separated and injected into a ribbon-like capillary device by continuous flow (GrFFF proprietary system). Cells were sorted into 6 fractions and absorbencies [optical density (OD)] were read. Six fractions from each of the 6 aliquots were then combined to provide pooled fractions that had adequate cell numbers to seed at equal concentrations into assays. Equine muscle tissue-derived, periosteal tissue-derived, bone marrow-derived, and adipose tissue-derived mesenchymal stem cells were consistently sorted into 6 fractions that remained viable for use in further assays. Fraction 1 had more cuboidal morphology in culture when compared to the other fractions. Statistical analysis of the fraction absorbencies (OD) revealed a P-value of < 0.05 when fractions 2 and 3 were compared to fractions 1, 4, 5, and 6. It was concluded that non-equilibrium GrFFF is a valid method for sorting equine muscle tissue-derived, periosteal tissue-derived, bone marrow-derived, and adipose tissue-derived mesenchymal stem cells into subpopulations that remain viable, thus securing its potential for use in equine stem cell applications and veterinary medicine.
Показать больше [+] Меньше [-]Evaluation of varying morphological parameters on the biomechanics of a cranial cruciate ligament–deficient or intact canine stifle joint with a computer simulation model
2014
Brown, Nathan P. | Bertocci, Gina E. | Marcellin-Little, Denis J.
Objective-To investigate the influence of varying morphological parameters on canine stifle joint biomechanics by use of a 3-D rigid-body canine pelvic limb computer model that simulated an intact and cranial cruciate ligament (CrCL)–deficient stifle joint across the stance phase of gait at a walk. Sample-Data from computer simulations. Procedures-Computer model morphological parameters, including patellar ligament insertion location, tibial plateau angle (TPA), and femoral condyle diameter (FCD), were incrementally altered to determine their influence on outcome measures (ligament loads, relative tibial translation, and relative tibial rotation) during simulation of the stance phase of gait at a walk. Outcome measures were assessed for each scenario and compared between an intact and CrCL-deficient stifle joint with the sensitivity index (the percentage change in outcome measure divided by the percentage change in input parameter). Results-In a CrCL-intact stifle joint, ligament loads were most sensitive to TPA. In a CrCL-deficient stifle joint, outcome measures were most sensitive to TPA with the exception of caudal cruciate ligament and lateral collateral ligament loads, which were sensitive to FCD and TPA. Relative tibial translation was sensitive to TPA and patellar ligament insertion location, whereas relative tibial rotation was most sensitive to TPA. Conclusions and Clinical Relevance-The computer model sensitivity analyses predicted that individual parameters, particularly TPA and FCD, influence stifle joint biomechanics. Therefore, tibial and femoral morphological parameters may affect the likelihood, prevention, and management of CrCL deficiency.
Показать больше [+] Меньше [-]Validation of stress magnetic resonance imaging of the canine stifle joint with and without an intact cranial cruciate ligament
2014
Tremolada, Giovanni | Winter, Matthew D. | Kim, Stanley E. | Spreng, David | Pozzi, Antonio
Objective-To validate use of stress MRI for evaluation of stifle joints of dogs with an intact or deficient cranial cruciate ligament (CrCL). Sample-10 cadaveric stifle joints from 10 dogs. Procedures-A custom-made limb-holding device and a pulley system linked to a paw plate were used to apply axial compression across the stifle joint and induce cranial tibial translation with the joint in various degrees of flexion. By use of sagittal proton density-weighted MRI, CrCL-intact and deficient stifle joints were evaluated under conditions of loading stress simulating the tibial compression test or the cranial drawer test. Medial and lateral femorotibial subluxation following CrCL transection measured under a simulated tibial compression test and a cranial drawer test were compared. Results-By use of tibial compression test MRI, the mean +/- SD cranial tibial translations in the medial and lateral compartments were 9.6 +/- 3.7 mm and 10 +/- 4.1 mm, respectively. By use of cranial drawer test MRI, the mean +/- SD cranial tibial translations in the medial and lateral compartments were 8.3 +/- 3.3 mm and 9.5 +/- 3.5 mm, respectively. No significant difference in femorotibial subluxation was found between stress MRI techniques. Femorotibial subluxation elicited by use of the cranial drawer test was greater in the lateral than in the medial compartment. Conclusions and Clinical Relevance-Both stress techniques induced stifle joint subluxation following CrCL transection that was measurable by use of MRI, suggesting that both methods may be further evaluated for clinical use.
Показать больше [+] Меньше [-]In vivo assessment of a multicomponent and nanostructural polymeric matrix as a delivery system for antimicrobials and bone morphogenetic protein-2 in a unicortical tibial defect in goats
2014
Rousseau, Marjolaine | Anderson, David E. | Lillich, James D. | Apley, Michael D. | Jensen, Peder J. | Biris, Alexandru S.
Objective-To determine the response of cortical bone to a multicomponent and nanostructural polymeric matrix as a drug delivery system for enhancing bone healing. Animals-20 healthy adult crossbred goats. Procedures-A 3.5-mm-diameter unicortical defect was created in each tibia (day 0), and goats (4 goats/group) were treated as follows: not treated (control group), grafted with the matrix, grafted with antimicrobial (tigecycline and tobramycin)-impregnated matrix, grafted with recombinant human bone morphogenetic protein type 2 (rhBMP-2)-impregnated matrix, or grafted with antimicrobial- and rhBMP-2-impregnated matrix. Elution kinetics of antimicrobials was monitored through plasma concentrations. Bone response was assessed with radiographic scoring (days 1 and 30) and dual-energy x-ray absorptiometry (days 1, 14, and 30). Goats were euthanized on day 30, and histomorphologic analysis was performed. Categorical variables were analyzed with a generalized linear model, and continuous variables were analyzed with an ANOVA. Results-Plasma antimicrobial concentrations indicated continued release throughout the study. Radiography and dual-energy x-ray absorptiometry did not reveal significant differences among treatments on day 30. Periosteal reactions were significantly greater surrounding bone defects grafted with rhBMP-2–impregnated matrix than those not treated or grafted with matrix or with antimicrobial-impregnated matrix; periosteal reactions were similar in bone defects grafted with rhBMP-2–impregnated matrix and antimicrobial- and rhBMP-2-impregnated matrix. Conclusions and Clinical Relevance-The matrix served as an antimicrobial delivery system and stimulated bone proliferation when rhBMP-2 was present. Antimicrobial and rhBMP-2 can be used concurrently, but the presence of antimicrobials may affect the performance of rhBMP-2.
Показать больше [+] Меньше [-]