An ultrasonographic off-set system for examination of equine tendons and ligaments
1991
Wood, A.K.W. | Newell, W.H. | Borg, R.P.
In a dorsal plane, an improved ultrasonographic off-set system was used to obtain serial ultrasonographic images with enhanced anatomic and pathologic detail of the tendons, ligaments, and associated structures of the limbs of 100 horses. The off-set provided good acoustic coupling between a linear array ultrasonographic transducer and the horse's skin. A water-soluble gel contained within the off-set had acoustic properties similar to those of mammalian soft tissues.
Показать больше [+] Меньше [-]Evaluation of the Doppler ultrasonic method of measuring systolic arterial blood pressure in cats
1992
Grandy, J.L. | Dunlop, C.I. | Hodgson, D.S. | Curtis, C.R. | Chapman, P.L.
The accuracy of the Doppler technique for indirect systolic blood pressure measurement was assessed in 16 anesthetized cats. Eight cats were anesthetized with isoflurane and 8 were anesthetized with halothane. Anesthetic depth and mode of ventilation were varied to obtain a wide range of arterial blood pressure. A Doppler transducer was placed on the palmer surface of the left fore-limb over the common digital branch of the radial artery to detect blood flow, and a blood pressure monitoring cuff with a width 37% the limb circumference was placed half way between the elbow and the carpus. To enable direct arterial pressure measurements, the left femoral artery was catheterized and the blood pressure waveforms recorded simultaneously. Systolic blood pressure measured by use of the Doppler ultrasonic technique was significantly lower than that obtained from the femoral artery catheter. Using linear regression, we determined a clinically useful calibration adjustment for Doppler indirect blood pressure measurement in cats: femoral systolic pressure = Doppler systolic pressure + 14 mm of Hg.
Показать больше [+] Меньше [-]Canine corneal thickness measured by ultrasonic pachymetry
1991
Gilger, B.C. | Whitley, R.D. | McLaughlin, S.A. | Wright, J.C. | Drane, J.W.
Ultrasonic pachymetry was used to measure central, superior peripheral, and temporal peripheral corneal thicknesses of 75 dogs (150 eyes) with normal corneas, anterior chambers, and intraocular pressure. Mean corneal thickness averaged over the 2 eyes, 3 locations, and 75 dogs was 562 +/- 6.2 micromole. The peripheral cornea was thicker on average than the central cornea by 49.43 +/- 8.45 micromole and this difference increased with age at 6.97 +/- 1.3 micromole/month of age. Mean corneal thickness changed with age (14.23 +/- 2.26 micromole/month), and weight (1.83 +/- 0.38 micromole/kg). Females had significantly thinner corneas (22.43 +/- 11.03 micromole than males) after adjusting for age and weight.