[Wastewater purification efficiency appreciation using a rapid microbiological test]
2001
Tibru, I. | Nichita, I. | Savescu, E. | Mircov, V.D. (Facultatea de Medicina Veterinara, Timisoara (Romania))
The surface water quality preservation is dependent on the used technology of wastewater purification, waters that are thrown in natural streams and on the used methods for the purification efficiency evaluation. The field microbiological test (FMT) is made of a concentrated culture medium that allows the evidencing of enterobacteria below values of 100/cubic cm, therefore it was used for sanitary ranking of treated wastewaters at the sewage treatment plant of Timisoara (Romania). We noted a 100% correlation between FMT and the official coliform bacteria test.
Показать больше [+] Меньше [-][Monitoring the decontamination degree of the slurry using the alternative aerobic and anaerobic fermentations]
2001
Tibru, I. | Nichita, I. | Savescu, E. | Mircov, V.D. (Facultatea de Medicina Veterinara, Timisoara (Romania))
This paper presents the results obtained after an alternative treatment (aerobic and anaerobic) of the animal slurry. We discussed only about the problems related to the effects of denitrification and dephosphatation on coliform bacteria. We noticed a good decontamination of the slurry using alternatively the two procedures. To determine the decontamination degree we used the classical multiple tubes method. The same samples were examined through the field microbiological test (FMT) adding Kovacs reagent. There is a concordance between the coliform bacteria determined through the classical method and the number determined through FMT to which the Kovacs reagent adding increases the sensitivity degree.
Показать больше [+] Меньше [-]Isolation, identification and bioremediation potential of oil-degrading bacteria from Manila Bay and Pasig River [Philippines]
1997
Dela Cruz, J. | Halos, P.M.
Oil-degrading bacteria were isolated from waters and sediments of the Manila Bay and Pasig River [Philippines]. Five types of bacteria were isolated from Manila Bay and four from Pasig River. The identified crude oil degrading species are Vibrio sp., Alcaligenes sp., Flavobacterium indologenes and Acinetobacter sp. from Manila Bay, and Pseudomonas aeruginosa, Bacillus sp., Micrococcus sp. and Pseudomonas putida from Pasig River. These isolates were identified through morphological and physiological characterization. The bioremediation potential for each of the isolates was assessed. The percentages oil conversion for the bacterial isolates ranged from 2.99 percent - 53.44 percent in one week's time. Alcaligenes sp. exhibited the highest biodegradation potential for all isolates. Statistical analysis revealed that the mean percentages diesel oil conversion by the isolates were significantly higher than their mean percentages crude oil conversion. Pure and mixed cultures did not give significant differences in their mean percentages crude oil conversion
Показать больше [+] Меньше [-]Wastewater irrigation effect on soil, crop and environment: a pilot scale study at Irbid, Jordan
1998
Shahalam, A. (Ohio State Univ., Coshocton, OH (USA). Outlying Station) | Abu-Zahra, B.M. | Jaradat, A.
Microbiological Examination of Water
2001
Ezzat, S. M. (Central Laboratory for Environmental Quality Monitoring, Cairo (Egypt)) | Tawfic, T. A.
Physical, chemical and microbiological analysis of rivers Mušnica and Suški potok [Bosnia and Herzegovina] as parameter of water quality | Fizičko-hemijska i mikrobiološka analiza rijeke Mušnice i Suškog potoka [Bosna i Hercegovina] kao parametri kvaliteta vode
2010
Lolić, S., Prirodno-matematički fakultet, Banja Luka (Bosnia and Herzegovina) | Golub, D., Prirodno-matematički fakultet, Banja Luka (Bosnia and Herzegovina) | Dekić, R., Prirodno-matematički fakultet, Banja Luka (Bosnia and Herzegovina) | Matavulj, M., Prirodno-matematički fakultet, Novi Sad (Serbia) | Ivanc, A., Fakultet za biofarming, Bačka Topola (Serbia)
During the summer 2009 physical, chemical, biochemical and bacteriological analyses of water of rivers Mušnica and Suški Potok were performed. Microbiological analysis point out that waters belong to the 2nd class by Kohl. The river Mušnica had slightly polluted water, and river Suški Potok had very slightly polluted water. According to the Regulation on Classification of Surface Waters in Republic of Srpska (Bosnia and Herzegivina) all the observed parameters belong to the first or second water quality class. Only the stream Suški Potok has chloride concentration that exceeds a third-class quality. On the basis of observed characteritics it can be concluded that Mušnica and Suški Potok have a satisfactory water quality.
Показать больше [+] Меньше [-]Microbiological characterization of water and sediment of the river Danube in the zone of drinking water sources of the city of Novi Sad [Serbia] | Mikrobiološka karakterizacija vode i sedimenta Dunava u zoni izvorišta vode za piće grada Novog Sada [Srbija]
2010
Knežević, P., Prirodno-matematički fakultet, Novi Sad (Serbia) | Simeunović, J., Prirodno-matematički fakultet, Novi Sad (Serbia) | Petrović, O., Prirodno-matematički fakultet, Novi Sad (Serbia)
The city of Novi Sad uses groundwater as drinking water source. For this purpose only water from Danube alluvium is used, and the water is abstracted at three sites. The Danube water and sediment quality in the zone of the drinking water sources is of great importance, as the river Danube recharge alluvial aquifer. The microbiological quality of these environments was monitored, in order to determine their influence on drinking water quality. The water characterization was carried out using sanitary and ecological microbiological parameters of Danube water and sediment.
Показать больше [+] Меньше [-]Aerobic mesophylic bacteria in bottled waters
2007
Knezevic, P.,Prirodno-matematicki fakultet, Novi Sad (Serbia). Departman za biologiju i ekologiju | Petrovic, O.,Prirodno-matematicki fakultet, Novi Sad (Serbia). Departman za biologiju i ekologiju
There was carried out microbiological analysis of five bottled water of manufacturers from Serbia. Bacteriological quality was estimated using important parameter-aerobic mesophylic bacteria. Two nutrient media were used: standard (PCA) and low nutrient R2A. Plates were incubated at two temperatures (37 deg C and 22 deg C) during 24 hours, 48 hours, 3 days and 5 days. Results show that this group of bacteria is very abudant in bottled waters and their number depends on water types and manufacturers. Moreover, water from different bottles of the same manufacturer has different microbiological quality. Used media, temperatures and period of incubation also have influence on results and R2A medium gives higher values of aerobic mesophylic bacteria.
Показать больше [+] Меньше [-]Chemistry and microbiology of Ranney well RB-7 encrustation in the Sava river alluvion [Serbia]
2007
Petkovic, A.,Institut za vodoprivredu Jaroslav Cerni, Beograd (Serbia) | Obradovic, V.,Institut za vodoprivredu Jaroslav Cerni, Beograd (Serbia)
Iron-related well-screen encrustation and aquifer biofouling has decreased the specific capacity of RB-7 well. This paper describes the role of iron-related bacteria in the encrustation process and relates their occurrence to chemical conditions in the well.
Показать больше [+] Меньше [-]BART tests in groundwater quality monitoring
2007
Obradovic, V.,Institut za vodoprivredu Jaroslav Cerni, Beograd (Serbia) | Petrovic, O.,Prirodno-matematicki fakultet, Novi Sad (Serbia). Departman za biologiju i ekologiju
Water wells are among the oldest hydraulic engineering structures in the world. Today, hundreds of water wells service water supply systems in Serbia, and groundwaters are widely used for public water supply. Extensive practical engineering experience in water well operation has identified a number of problems which affect well service life and capacity (i.e. reduce specific yield). Some of the encountered problems are, also, a result of microbial activity in groundwater. Products of life processes of groundwater specific microbial community cause biocorrosion, blockage, closure, plugging, deposition, and biofouling of well screens and collectors. We applied BART biodetectors as a reliable tool in monitoring well rehabilitation effectiveness. This paper presents several process assessments based on BART biodetector tests conducted at Belgrade groundwater source.