Drinking water quality in Podgorica [Montenegro, Serbia&Montenegro] - dependence of chlorination by products concentration on the organic matter in water
2003
Karajic, M. | Djurovic, D. (Institut za zdravlje Crne Gore, Podgorica (Serbia and Montenegro))
Presentation is dealing with data on raw and drinking water quality of water supply sources and water supply systems in Podgorica, Montenegro (Serbia&Montenegro). Special attention was paid to organic matter content, concentration of disinfectants and disinfection by-products. Average values of all parameters examined are below maximum permissible levels defined by regulations. That means that physical-chemical quality of water is excellent.
Показать больше [+] Меньше [-]Non-conventional water treatment techniques prior slow sand filtration
2003
Ljubisavljevic, D. | Jovanovic, B. (Univerzitet u Beogradu, Beograd (Serbia and Montenegro). Gradjevinski fakultet)
Slow sand filtration is an effective water treatment process. However, the performance of slow sand filters is influenced by the raw water turbidity. Filtration on pebble-matrix and roughing filters is introduced as a process effective in reduction of raw water turbidity. Efficiencies of these pretreatments documented on the raw water sources world-wide are presented in this paper as well as the investigation results from the similar raw water source in Serbia (Serbia&Montenegro).
Показать больше [+] Меньше [-]The efficiency of the drinking water plant in Grgurovci [Serbia, Serbia&Montenegro] after the technological-technical reconstruction
2003
Cibulic, V. (Zavod za zastitu zdravlja, Leskovac (Serbia and Montenegro)) | Perisic, M. (Geo institut, Beograd (Serbia and Montenegro))
The results of a study on the water of the Sumanka river during several years point out the decrease in its quality. The results of the present study show that the technological actions, as well as the some technical changes, carried out in the Lebane's plant in Grgurovci gave the satisfactory effects. Turbidity, colour, KMnO4 demand and ammonia are efficiently reduced, along with low concentrations of Fe, Mn, and residual Al, ensure completely the water standard quality in accordance with the Protocol.
Показать больше [+] Меньше [-]Application of membrane processes in potable water treatment
2003
Cakic, B. | Popovic, L. | Ljuboja, M. | Svrkota, D. (Institut za vodoprivredu "Jaroslav Cerni", Beograd (Serbia and Montenegro))
Membrane processes is gaining broad application in potable water treatment. Experience in application of membrane system for treatment of potable water so far showed that these systems have wide range of advantages versus conventional treatment: lower capital costs, lower operation costs, use of chemicals is minimal; space for installation is much smaller, usage of chlorine for disinfection is minimal due to significant reduction of microorganisms; sludge production during the process is smaller due to smaller usage of chemicals, construction period is shorter due to smaller scope of works and relatively simply installation of membrane batteries.
Показать больше [+] Меньше [-]The Zidine infiltration water source [Serbia, Serbia&Montenegro] - preliminary treatment plant
2003
Dimkic, D. | Ljuboja, M. | Popovic, L. | Vulic, D. (Institut za vodoprivredu "Jaroslav Cerni", Beograd (Serbia and Montenegro))
The area of Zidine is located southwest of Belgrade, Serbia&Montenegro, in the sanitary protection zone of the existing Belgrade water source. This potential water source is capable of yielding water of better quality than that of the existing raw groundwater, for final treatment plants at Bezanija and Banovo Brdo. In view of available capacities of these plants and the raw water system, the water disposal issue is practically resolved and the water source is also highly advantageous in economic terms. Two options of preliminary treatment after settling were considered: sand filters and microfilters.
Показать больше [+] Меньше [-]Biological denitrification in drinking water treatment
2003
Ljubisavljevic, D. | Dakovic, S. (Univerzitet u Beogradu, Beograd (Serbia and Montenegro). Gradjevinski fakultet)
According to existing national Standard for drinking water quality NO3 sup(-) ion is limited to 50 mg/l. Removal of NO3 sup(-) concentration greater than this limit is necessary. One of the possible methods is biological denitrification with CH3OH. Principals of this method are described in this paper with recommendation for construction of pilot plan on the specific groundwater source.
Показать больше [+] Меньше [-]Use of powdered activated carbon for better removal of natural organic matter from groundwater by coagulation and flocculation
2003
Dalmacija, B. (Prirodno-matematicki fakultet, Novi Sad (Serbia and Montenegro). Departman za hemiju) | Klasnja, M. | Agbaba, J. | Ivancev-Tumbas, I. | Becelic, M.
The process of removal of natural organic matter from groundwater by adsorption on powdered activated carbon, coagulation and flocculation was investigated. It was found that the combination of these processes yielded a decrease of KMnO4 values, which allowed the reduction of the coagulant concentration, needed to achieve the necessary quality of drinking water, up to 50%. Also, it was established that the sequence of adding powdered activated carbon and coagulant is one of the essential factors determining the efficiency of NOM removal from water, and which is primarily conditioned by the nature of the organic matter present in the investigated water.
Показать больше [+] Меньше [-]Effects of preozonation on natural organic matter removal from groundwater by coagulation and flocculation processes
2003
Agbaba, J. (Prirodno-matematicki fakultet, Novi Sad (Serbia and Montenegro). Departman za hemiju) | Dalmacija, B. | Klasnja, M. | Ivancev-Tumbas, I.
The paper deals with pilot-scale investigations of the effect of preozonation on NOM removal from groundwater by coagulation and flocculation processes. It was found that the preozonation increased the efficiency of organic matter removal by coagulation and flocculation from 23.6 to 47.2% as judged on the basis of KMnO4 values. From the aspect of the change of content of trihalomethanes precursors preozonation exhibits both the positive and negative effects if their content in the water after coagulation is considered in dependence of the applied ozone dose. The obtained values siggest the necessity of careful optimization of the processes of preozonation, coagulation, and flocculation, especially from the aspect of the change in content of the precursors of disinfection byproducts.
Показать больше [+] Меньше [-]Some new technological solutions for arsenic removal from water
2006
Jovanovic, B. (Gradjevinski fakultet, Beograd (Serbia)), E-mail: brana@grf.bg.ac.yu | Rajakovic, V. (Gradjevinski fakultet, Beograd (Serbia)) | Babic, B. (Gradjevinski fakultet, Beograd (Serbia)) | Ljubisavljevic, D. (Gradjevinski fakultet, Beograd (Serbia)) | Rajakovic, Lj. (Tehnolosko-metalurski fakultet, Beograd (Serbia))
In this paper two different combinations for wastewater treatment are proposed for specific problems that Vojvodina (Serbia) has with arsenic. Both proposed technologies take into account treatment of water and treatment of waste. In this paper the concrete solution for water treatment is proposed for water that contains arsenic (the concentration is around 100 microgram/L) in Obrovac and Palic. With these water treatment plants the removal of ammonia (measured concentration was above the maximum allowed value, from 1.35-2.5 mg/L) is also included in case of Obrovac wastewater plant, and for Palic the proposed treatment plant the removal of iron (measured concentration was above the maximum allowed value, from 1.35-2.5 mg/L) is also included. With both treatment plants and with both proposed technologies the overall treatment of water is planned.
Показать больше [+] Меньше [-]Oxidation of high concentrations of ammonia from groundwater - example: purification of drinking water in the Grocka municipality [Serbia]
2006
Perisic, M. (Univerzitet u Beogradu, Beograd (Serbia). Centar za multidisciplinarne studije), E-mail: perisicmi@sezampro.yu | Stevanovic, S. (JKP Vodovod, Grocka (Serbia)) | Natic, D. (Institut za zastitu zdravlja Republike Srbije Dr Milan Jovanovic Batut, Beograd (Serbia)) | Karadzic, V. (Institut za zastitu zdravlja Republike Srbije Dr Milan Jovanovic Batut, Beograd (Serbia))
The paper analyses application of different methods for removal of the high content of ammonia from groundwater sources of the Grocka municipality neighborhoods Umcari and Pudarci. According to the relevant data from this field method, biochemical oxidation with the Nitrosomonas and Nitrobacter bacteria was used. Parameters of biological processes of the ammonia oxidation were defined on the pilot model located at the groundwater source. On the pilot model, consisting of a trickling filter and a fast gravel filter, quantitative oxidation NH4 to NO3 was done. Purification plant was designed with parameters of the pilot model, with minimal investment and exploitation expenses, without undesired side products and ecological risks characteristic for procedure of chemical oxidation of ammonia, which recommends this procedure as the optimal solution.
Показать больше [+] Меньше [-]