Уточнить поиск
Результаты 11-18 из 18
Quartz Mineral as new Sorbent for Hg(II) Removal from Aqueous Solution: Adsorption Kinetics and Isotherm
2023
Labidi, Sofiane | Mechati, Boukoffa
Natural quartz mineral was examined as a new sorbent for Hg(II) removal from synthetic wastewater systems. Batch adsorption experiments of Hg(II) onto quartz mineral were conducted under various conditions such as solution pH, sorbent dosage, contact time, initial Hg(II) concentration. Adsorption experiments results of Hg(II) by quartz mineral showed good achievement after 180 min with 1.0 g/L sorbent mass at pH of 2.0, agitation speed of 200 rpm and a temperature of 25°C. Moreover, the Hg(II) concentration was directly related to increases the adsorption capacity, the maximum Hg(II) uptake by quartz sample was 16.52 mg/g for 80 mg/L (C0 (Hg(II)]. Langmuir isotherm and pseudo-second-order kinetics (R2 > 0.99) were found to be the most appropriate models to describe the adsorption of Hg(II) by quartz mineral. The intra-particle diffusion model and the calculated Dubinin–Radushkevich adsorption energy (Eads = 0.78 kJmol-1), confirms a physisorption adsorption reaction occurring in three stages.
Показать больше [+] Меньше [-]Status and evaluation of the selected soil nutrients irrigated by unconventional water (Case study: Qom)
2016
Arast, Mina | Zehtabian, Gholamreza | Jafari, Mohammad | Khosravi, Hassan | Jabalbarezi, Bahareh
Population’s exponential growth along with drought has increased water resources limitation, especially in arid and semi-arid area. Therefore, the use of non-conventional water is an important tool for water resource management. If unconventional water has no negative impact on soil properties and water, it can be used for irrigation coupled with desertification projects. So, this paper tries to present the effect of irrigation with municipal wastewater, salt water, brackish water, and combination of salty water and wastewater on some soil properties including nitrogen, phosphorus, and potassium in Qom plain. Soil samples were taken from agricultural land treated by wastewater, saline water, brackish water, combination of salty water, and wastewater and range land as control in five treatments from depths of 0-30 and 60-90 centimeter. The results showed that wastewater has increased the amount of N, P, and K to other treatments and control area. The concentration of potassium in surface layer of area treated by combination of salty water and wastewater with amount of 459.39 ppm has the most significant difference to control and other treatments. Also, the maximum amount of nitrogen was observed in sub layer of saline and brackish water treatment with amount of 0.08 percent.
Показать больше [+] Меньше [-]Concentration of Selected Phenolic Compounds in Effluent, Stream and Groundwater of a Local Textile Industry in Abeokuta, Ogun State, Nigeria
2024
Olayinka, Olufunmilayo | Egbeyemi, Morenikeji | Oyebanji, Adedayo
Phenols have attracted global interest in the sphere of environmental management due to their potential toxicity on human health. This study determined concentrations of three priority phenolic compounds in effluent and water of a local textile industry in Abeokuta, Nigeria. During tie-dye production, triplicates of effluent, well water, stream and control water were collected three times from five points to give a total of forty-five samples. Physicochemical parameters of samples including temperature, pH, electrical conductivity (EC), total suspended solids (TSS) and total dissolved solids (TDS) were determined according to standard methods while the concentrations of the priority phenolic compounds (4-nitrophenol, 4-chloro-3-methylphenol and 2, 4-dinitrophenol) were determined using High Performance Liquid Chromatography equipped with Ultra-Violet detector (HPLC/UV). Data obtained were subjected to descriptive (mean and standard deviation) and inferential (ANOVA) statistics. pH, EC and TSS of effluent and water samples were higher than the permissible limits of World Health Organization (WHO) and Federal Environmental Protection Agency (FEPA) while temperature of the effluent samples and TDS of the well water samples were within standard values. Higher concentrations of the priority phenolic compounds occurred in effluent than water samples but 4-nitrophenol was below detection limit (DL) in water samples. Concentrations of 4-nitrophenol, 4-chloro-3-methylphenol and 2,4-dinitrophenol in effluent exceeded stipulated standard of WHO (0.01 mg/L) and water samples. High concentrations of phenols in water bodies at the local textile industry suggest uncontrolled discharge of effluent from the industry which could eventually reach surface and ground water with potential significant health implications to the populace.
Показать больше [+] Меньше [-]Application of Electrochemical Disinfection Process Using Aluminum Electrodes for Efficient Removal of Coliforms from Wastewater
2024
Nabi Bidhendi, Amir | Mehrdadi, Nasser | Karbassi, Abdolreza
In this work, it was attempted to evaluate and demonstrate disinfection effectiveness of an electrochemical process to entirely remove coliform from wastewater effluent following secondary treatment. For the tests, an experimental bench-scale batch electrochemical cell was constructed, and aluminum electrodes were employed in the electro-disinfection reactor. In the electric disinfection phase, wastewater samples were put in the reactor/disinfector and a direct current (DC) was applied to it. According to findings, a significant decrease occurred in the total number of coliforms in the treated wastewater, and a high improvement occurred in the effluent properties. At a contact time of 15 min and a current density of 5.5 mA/cm2, led to a bacterial killing effectiveness of 97.7% or above. As the current density and contact time increased, a general increase occurred in the bacterial killing efficiency, and the effect of the two above-mentioned factors was much greater than the effect of salinity. Moreover, according to the experimental data, the removal efficiency of chemical oxygen demand (COD) and total suspended solids (TSS) by the aluminum electrodes were 78.50% and 99.93%, respectively. The findings indicate the applicability of the proposed electrochemical treatment to wastewater effluent. Nevertheless, to be able to apply this system at an industrial scale in the future, it is necessary to conduct more research into the optimum operation conditions and make an in-depth comparison of energy consumptions between the electrochemical treatment and the conventional approaches.
Показать больше [+] Меньше [-]Identification and Quantification of Antibiotic Residues and Evaluation of Microbial Resistance to Antibiotics in Huatanay River Waters in Peru
2023
Del Castillo De Loayza, Tatiana | Maldonado, Ingrid | Zirena Vilca, Franz
The Huatanay River in Cusco-Peru, is affected by wastewater discharges along its course. In order to evaluate this impact, we evaluate antibiotic residues and their impact on the increase of bacterial resistance in the city of Cusco treatment plant. For this purpose, water samples from the influent and effluent of the treatment plant were analyzed by chromatographic methods; additionally, sensitivity tests were performed with three bacterial strains (Escherichia coli, Salmonella sp., and Klebsiella sp.), which were isolated from the same place. Six antibiotic residues were identified (ceftriaxone, amoxicillin, trimethoprim, sulfamethoxazole, dicloxacillin, and lincomycin). Those found in the highest concentration were: amoxicillin (91495 and 0 µg/L) and lincomycin (33970 and 10800 µg/L) in the influent and effluent, respectively. There is more resistance in the effluent than the influent in the case of E. coli shows resistance in the effluent to cephalexin (30 µg) and azithromycin (15 µg). Salmonella sp. is resistant to amoxicillin (15 µg), dicloxacillin (1 µg), lincomycin (2 µg), ceftriaxone (30 µg), cephalexin (30 µg), and ciprofloxacin (5 µg). Finally, Klebsiella sp. is sensitive to ceftriaxone (30 µg), amoxicillin (15 µg), and cephalexin (30 µg). This confirms that the antibiotic residues contained in the wastewater of Cusco generate resistance in the isolated bacteria.
Показать больше [+] Меньше [-]Engineering Properties of Substrate used in Constructed Wetlands Treating low Strength Sewage under Tropical Conditions
2023
Vishwakarma, Smily | Dharmendra, Dharmendra | Singh, Rohit | Bharti, Bharti | Ankita, Ankita
Substrates play a major role to filter, adsorb, sediment, flocculate, precipitate, and exchange ions. In CW (Constructed wetland), selecting substrate or bed materials is not difficult, as locally accessible, cost-effective, and environment-friendly materials can be used based on size, hydraulic conductivity, texture, porosity, etc. CW substrates undergo a multitude of purification processes, including physical filtration and sedimentation, sorption, ion exchange and microbial degradation, precipitation, and bio-immobilization in the substrate, in addition to uptake and metabolism by macrophytes. With constructed wetlands, treatment facilities with well-defined substrates, vegetation species, and flow patterns can be built with greater control than with natural systems. This report details investigations of some of the locally available substrates that all fit the requirements. Based on analysis of parameters which are pH, water absorption capacity, hydraulic conductivity, porosity, surface area, bulk density, particle size distribution, D10 particle diameter, D60 uniformity coefficient, permeability and specific gravity, a comparison of four materials is presented in this paper. The study found that the construction waste materials evaluated showed satisfactory physical properties for use as filler media in constructed wetlands for wastewater treatment.
Показать больше [+] Меньше [-]Model for the Treatment of Refinery Wastewater and expression of catabolic genes in Fluidized Bed Bioreactor using mixed bacterial consortium
2019
Ajao, A. T. | Mustapha, M. O. | Yakubu, S. E.
This study was undertaken to evaluate a novel aerobic wastewater treatment model for the remediation of refinery effluents and to assess the removal efficiency of Bulkholderia cepacia strain AJI and Corynebacterium kutscheri strain AJ2 to clean oil waste from petrochemical company. Wastewater quality parameters including pH, BOD5, COD, TDS, OIL & GREASE, PHENOL concentration, TPH and THC were monitored at 5, 10 and 15 days of treatment and the removal efficiencies were calculated. Results indicated that the raw oily wastewater effluents used during this study had extremely high levels of all the tested parameters. The mean values of all physicochemical parameters of the wastewater from primary tank at different treatment period were statistically different (P˂0.001) After 15 days of biological treatment, BOD5 ,COD, TDS, Phenol, TPH, Oil & grease level of the refinery wastewater were reduced by 95.60 %, 98.40 % , 66.34 % , 100 %, 97.60 % and 96.20 % respectively. The detection of the catabolic genes in the bacterial isolates recovered from primary tank using polymerase chain reaction revealed that both Bulkholderia cepacia strain AJ1 and Corynebacterium kutsheri strain AJ2 carried alk B and C23O but C12O was not detected in both isolates. Naphthalene dioxygenase was detected in Bulkholderia cepacia strain AJ1 but not found in Corynebacterium kutscheri strain AJ2. After treatment the waste water was filtered in the secondary tank. The results of physicochemical parameters in the outlet vessel essentially confirmed that the mixed culture in the two column model successfully carry out bioremediation of refinery wastewater. Therefore, aerobic treatment model for the bioremediation of refinery Petroleum refineries generate great amounts of wastewaters that may become seriously dangerous, leading to the accumulation of toxic products in the receiving water bodies with potentially serious long term effects to aquatic biota. Due to extreme toxicity of contaminants in refinery wastewater, there is a need to develop an economical technique to remove the pollutants from the wastewater is highly recommended owing its environmental friendliness.
Показать больше [+] Меньше [-]Characterization of Textile Effluents from Dhaka Export Processing Zone (DEPZ) Area in Dhaka, Bangladesh
2016
Kamal, Abdul Kadir Ibne | Ahmed, Fahad | Hassan, Mahmud | Uddin, Md. Khabir | Hossain, Syed Mohammod
The present study has been undertaken in a laboratory scale to characterize and investigate pollution potential of textile effluents from DEPZ area in Dhaka, Bangladesh. Collected effluent samples from five different industries were analyzed for physico-chemical parameters using field kits and Standard Methods, and for metals using Flame Atomic Absorption Spectrophotometer (FAAS). The average physico-chemical parameters such as temperature, color, pH, DO, EC, BOD, COD, TS, total alkalinity and total hardness were found 52.4 ºC, 2646 PCU, 9.788, 1.492 mg/L, 7473.2 μS/cm, 157 mg/L, 508.8 mg/L, 9140.8 mg/L, 761.2 mg/L and 189.6 mg/L, respectively. The average concentrations of metal found in the textile effluents were in the order of Na (4611.762 mg/L) > Ca (9.166 mg/L) > Mg (3.578 mg/L) > Zn (0.113 mg/L) > Ni (0.0074 mg/L) > Cu (0.0032 mg/L). All the measured physico-chemical parameter values are negatively deviated but metal concentrations (except Na) are positively deviated from standard limits of wastewater discharge set by Department of Environment and US Environmental Protection Agency. In view of those characteristics, the textile industry effluents should be considered to be treated by setting eco-friendly effluent treatment plant (ETP) before directly discharging into the water bodies.
Показать больше [+] Меньше [-]