Уточнить поиск
Результаты 1-7 из 7
A turn-on fluorescent chemosensor selectively detects cyanide in pure water and food sample Полный текст
2016
Wei, Tai-Bao | Li, Wen-Ting | Li, Qiao | Su, Jun-Xia | Qu, Wen-Juan | Lin, Qi | Yao, Hong | Zhang, You-Ming
A turn-on fluorescent chemosensor (H-1) for cyanide anions based on dihydroxy phenazine was designed and synthesised. The sensor H-1 exhibits high sensitivity and good selectivity for cyanide in pure water. The CN− response mechanism involves a hydrogen bonding and deprotonation process in the sensor, which induced prominent fluorescence enhancement. The detection limit of the sensor toward CN− is 5.65×10−7M, and other anions had nearly no influence on the probing behavior. In addition, test strips based on the sensor were fabricated, which also exhibit a good selectivity to CN− in water. Notably, this sensor was successfully applied to detect CN− in food samples, which proves a very simple and selective platform for on-site monitoring of CN− in agriculture samples.
Показать больше [+] Меньше [-]Development of cloud-point extraction method for preconcentration of trace quantities of cobalt and nickel in water and food samples Полный текст
2016
Gouda, Ayman A. | Summan, Abdulhadi M. | Amin, Ali H.
A new, efficient, and sensitive cloud point methodology was developed for preconcentration of trace quantities of cobalt and nickel in water and food samples prior to their determination by flame atomic absorption spectrometry (FAAS). The metals react with 2-(benzothiazolylazo)-4-nitrophenol (BTANP) at pH 7.0 and micelle-mediated extraction using the nonionic surfactant Triton X-114 medium. The surfactant-rich phase was diluted with acidified methanol and the cobalt and nickel content was determined by FAAS. The optimum conditions (e.g. pH, reagent and surfactant concentrations, temperature and centrifugation times) were evaluated and optimized. The proposed CPE method showed linear calibration within the ranges 5.0–100 and 5.0–150 ng mL⁻¹ of cobalt and nickel, respectively, and the limits of detection of the method was 1.4 and 1.0 ng mL⁻¹ of cobalt and nickel, respectively. The interference effect of some cations and anions was also studied. The method was applied to the determination of both metals in water and food samples with a recovery from the spiked water samples in the range of 95–102%. The validation of the procedure was carried out by analysis of a certified reference material.
Показать больше [+] Меньше [-]Preconcentration of Cd(II) and Cu(II) ions by coprecipitation without any carrier element in some food and water samples Полный текст
2011
Duran, Celal | Ozdes, Duygu | Sahin, Deniz | Bulut, Volkan Numan | Gundogdu, Ali | Soylak, Mustafa
A simple, rapid, sensitive and environmentally friendly separation and preconcentration procedure, based on the carrier element free coprecipitation (CEFC) of Cu(II) and Cd(II) ions by using an organic coprecipitant, 2-{[4-(4-fluorophenyl)-5-sulphanyl-4H-1,2,4-triazol-3-yl]methyl}-4-{[(4-fluorophenyl) methylene]amino}-5-(4-methylphenyl)-2,4-dihydro-3H-1,2,4-triazol-3-one (MEFMAT) was developed. The analyte ions were determined by flame atomic absorption spectrometric (FAAS) determinations. The optimum conditions for the coprecipitation process were investigated on several commonly tested experimental parameters such as pH of the solution, amount of MEFMAT, sample volume, standing time, centrifugation rate and time. The influences of some anions, cations and transition metals on the recoveries of analyte ions were also investigated, and no considerable interference was observed. The preconcentration factor was found to be 50. The detection limits for Cu(II) and Cd(II) ions based on the three times the standard deviation of the blanks (N:10) were found to be 1.49 and 0.45μgL⁻¹, respectively. The relative standard deviations were found to be lower than 3.5% for both analyte ions. The method was validated by analyzing two certified reference materials (CRM-TMDW-500 Drinking Water and CRM-SA-C Sandy Soil C) and spike tests. The procedure was successfully applied to sea water and stream water as liquid samples and tobacco, hazelnut and black tea as solid samples.
Показать больше [+] Меньше [-]Cadmium and nickel determinations in some food and water samples by the combination of carrier element-free coprecipitation and flame atomic absorption spectrometry Полный текст
2013
Bahadir, Zekeriyya | Ozdes, Duygu | Bulut, Volkan Numan | Duran, Celal | Elvan, Hamide | Bektas, Hakan | Soylak, Mustafa
A procedure for separation and enrichment of Cd(II) and Ni(II) ions based upon carrier element-free coprecipitation by using an organic coprecipitant, 2-{4-[2-(1H-Indol-3-yl)ethyl]-3-(4-methylbenzyl)-5-oxo-4,5-dihydro-1H-1,2,4-triazol-1-yl}-N′-(3-fluoro-phenylmethyliden) acetohydrazide, prior to their flame atomic absorption spectrometric detections has been developed. The effects of varied experimental conditions on the performance of the developed method such as pH, sample volume, amount of coprecipitating agent, etc. were evaluated in detail on the recovery of analyte ions, and the influences of some anions and cations were investigated. The limits of detection for Cd(II) and Ni(II) ions based on three times the standard deviation of the blanks (N: 10) were obtained as 0.70 μg L⁻¹ and 1.21 μg L⁻¹, respectively. The accuracy of the method was tested by analyzing a certified reference material and by spike tests. The method was applied to determine the levels of cadmium and nickel in stream and sea water, rice, red lentil, and wheat samples.
Показать больше [+] Меньше [-]Solid phase extraction of lead, cadmium and zinc on biodegradable polyhydroxybutyrate diethanol amine (PHB-DEA) polymer and their determination in water and food samples Полный текст
2016
Tuzen, Mustafa | Sahiner, Samet | Hazer, Baki
A new biodegradable polyhydroxybutyrate diethanol amine (PHB-DEA) polymer was used as adsorbent for the sensitive and selective separation, preconcentration and determination of Pb(II), Cd(II) and Zn(II) by using atomic absorption spectrometry. Diethyl dithiocarbamate was used as chelating reagent. Analytical parameters such as pH, eluent type and its volume, flow rates of sample solution, ligand amount, sample volume were optimized. Effects of some cations, anions and transition metal ions were also investigated. Enrichment factor and relative standard deviation were found to be 100 and 3%, respectively. The limits of detection based on three times standard deviation of blanks (N=21) were found 1.05μgL−1 for Pb(II), 0.42μgL−1 for Cd(II) and 0.13μgL−1 for Zn(II). Limits of quantification (10s, N=21) were found 3.47μgL−1 for Pb(II), 1.39μgL−1 for Cd(II) and 0.43μgL−1 for Zn(II). Accuracy evaluation of the method was confirmed with analyses of certified reference materials (NIST SRM 1515 Apple leaves, IAEA 336 Lichen, GBW 07605 Tea). Optimized method was applied to tap water and food samples after microwave digestion method. Cadmium and lead values in some samples were found higher than legal limits.
Показать больше [+] Меньше [-]A newly synthesized graft copolymer for magnetic solid phase microextraction of total selenium and its electrothermal atomic absorption spectrometric determination in food and water samples Полный текст
2019
Acikkapi, Ayse Nihan | Tuzen, Mustafa | Hazer, Baki
A newly synthesized polystyrene-g-polyoleic acid-g-polyethylene glycol graft copolymer (PoleS-PEG) was used as adsorbent in the solid phase microextraction of selenium ions by using electrothermal atomic absorption spectrometry (ETAAS). Neodymium magnet was used for separation of analyte ions. Various analytical parameters such as pH, adsorbent amount, mixing time, eluent solution, sample volume, etc. were optimized. The matrix effects of some cations and anions were also studied. The capacity of the adsorbent was found 11.5 mg g−1. The preconcentration factor was found to be 50. The detection limit (LOD) and quantification limit (LOQ) were found 6.06 ng L−1 and 20 ng L−1, respectively. The calibration curve was linear in the range of 0.02–4.0 μg L−1. Relative standard deviation was found 3.2%. The accuracy of the method was provided by using standard reference materials. The optimized method was successfully applied to natural water and food samples.
Показать больше [+] Меньше [-]A fully water-soluble Calix[4]arene probe for fluorometric and colorimetric detection of toxic hydrosulfide and cyanide ions: Practicability in living cells and food samples Полный текст
2023
Oguz, Alev | Oguz, Mehmet | Kursunlu, Ahmed Nuri | Yılmaz, Mustafa
Although hydrosulfide and cyanide anions play important roles in daily life that they are available in a lot of foods. However, their excess amounts contaminate water, land, and food and cause serious problems to human health. Herein, we introduce a water-soluble macrocyclic sensor based-on Calix[4]arene (MPI-Calix[4]) with dual response sites for fluorescence recognizing cyanide (CN–) and hydrogen sulfide (HS⁻) under longwave light. MPI-Calix[4] exhibits a high selectivity and sensitivity in the detection of CN– and HS⁻, where the limits of detection were as low as 0.115 and 8.12 μmol/L, respectively. The cell imaging studies shows that this probe can be easily used in the detection of CN– and HS⁻ on living cells. Full understanding of these results paved a fruitful system to improve an applicable analytical process for food safety and quality.
Показать больше [+] Меньше [-]